manualshive.com logo in svg
background image

 

CVI, LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the 
Eagle logo are trademarks of National Instruments Corporation. Refer to the 

Trademark Information 

at 

ni.com/trademarks

 for other National Instruments trademarks. The mark LabWindows is used 

under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft 
Corporation in the United States and other countries. Other product and company names mentioned 
herein are trademarks or trade names of their respective companies. For patents covering 
National Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your 

software, the 

patents.txt

 file on your media, or the 

National Instruments Patent Notice

 at 

ni.com/patents

.

© 2010 National Instruments Corporation. All rights reserved.

373718A-01

Oct10

7.

Stop the generation.

8.

Clear the generation.

9.

Disconnect the counter from the C Series module.

The counter on the NI cDAQ chassis is now verified.

Where to Go for Support

The National Instruments Web site is your complete resource for technical support. At 

ni.com/

support

 you have access to everything from troubleshooting and application development self-help 

resources to email and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, 
Texas, 78759-3504. National Instruments also has offices located around the world to help address 
your support needs. For telephone support in the United States, create your service request at 

ni.com/support

 and follow the calling instructions or dial 512 795 8248. For telephone support 

outside the United States, contact your local branch office: 

Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, 
Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800, 
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, Finland 358 (0) 9 725 72511, 
France 01 57 66 24 24, Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, 
Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28, 
Malaysia 1800 887710, Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466, 
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 328 90 10, 
Portugal 351 210 311 210, Russia 7 495 783 6851, Singapore 1800 226 5886, 
Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197, Spain 34 91 640 0085, 
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, Taiwan 886 02 2377 2222, 
Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545

Содержание cDAQ

Страница 1: ...support for the ADE that you intend to use Documentation Requirements For information about NI DAQmx and NI cDAQ chassis you can consult the following documents DAQ Getting Started guides These guides provide instructions for installing and configuring NI DAQ devices NI DAQmx Help This help file contains general information about measurement concepts key NI DAQmx concepts and common applications t...

Страница 2: ...ature will be greater than the ambient temperature Keep relative humidity below 90 Allow a warm up time of at least 10 minutes to ensure that the measurement circuitry is at a stable operating temperature Calibration Procedures The calibration process includes the following steps 1 Initial Setup Install the device and configure it in Measurement Automation Explorer MAX 2 Verification Verify the ex...

Страница 3: ... the C Series module Figure 1 NI 9401 and NI 9402 Pin Assignments 2 Create and configure a counter output channel according to Table 2 3 Start the generation of a square wave 4 Configure the counter to measure frequency and use a 1 MΩ impedance 5 Take a measurement of the square wave 6 Compare the counter reading to the limits in Table 3 Table 2 Counter Output Configuration Frequency Scaled Units ...

Страница 4: ...on development self help resources to email and phone assistance from NI Application Engineers National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and fol...

Отзывы: