SC-2070 Board
Chapter 2
SC-207X Series User Manual
2-4
© National Instruments Corporation
W1
W1
W1
T
emp
CH8
CH0
T
emp
CH8
CH0
T
emp
CH8
CH0
a. Channel 0 and
Channel 8 Selected
b. Temperature Sensor
Selected
Differential Inputs
c. Temperature Sensor
Selected
Single-Ended Inputs
Figure 2-3. W1 Jumper Settings
Shield Ground
Jumper W2 is used to connect digital ground (DGND) to a grounded metal case. This option is useful
only if the SC-2070 board is on metal standoffs and is mounted in a grounded metal case. Select shield
grounding to reduce noise. Figure 2-4 details the jumper settings for W2.
W2
a. Shield Ground Selected
W2
b. Shield Ground Not Selected
Figure 2-4. W2 Jumper Settings
Fuse and Power LED
The +5 V line from the DAQ board is protected by an 800 mA fuse. If the red power LED does not
light when the DAQ board is powered on, check both the 800 mA fuse on the SC-2070 board and the
output fuse (if any) on the MIO-16 board. See Chapter 5, Installation and Connections, for
information on connecting power.
Digital and Timing Signals
All of the signals from the MIO-16 board are made available at screw terminals on the SC-2070 board.
Because these signals are not conditioned or changed in any way by the SC-2070 board, refer to your
MIO-16 board user manual for information on using these signals. If you want optical isolation of or
relay control by the digital I/O lines, then you must use the SC-2050 cable adapter board and the
appropriate SC-2060 digital signal conditioning board. For more information on the SC-205X Series
boards or the SC-206X Series boards, refer either to your National Instruments catalog, the SC-205X
Series User Manual, or the SC-206X Series User Manual.