Chapter 2
SC-2070 Board
© National Instruments Corporation
2-5
SC-207X Series User Manual
Board-to-Board Cabling
The SC-2070 board connects directly to any of the DAQ boards listed in Table 2-2.
Table 2-2. DAQ Boards Used with the SC-2070 Board
NB Series
(Macintosh)
MC Series
(IBM PS/2)
AT Series
(PC AT)
SC-2070
NB-MIO-16
MC-MIO-16
AT-MIO-16
NB-MIO-16X
AT-MIO-16D
*
AT-MIO-16F-5
AT-MIO-16X
AT-MIO-64F-5
*
*
Requires an NB5 cable, available separately.
The DAQ boards listed in Table 2-2 connect to the SC-2070 board as shown in Figure 2-5.
If you are using the SC-2070 board with the AT-MIO-16D or AT-MIO-64F-5 board, the 50-conductor
cable is replaced with a type NB5 100-conductor ribbon cable. The NB5 cable terminates with two
50-pin connectors, one of which may be connected to the SC-2070 board.
MIO-16
SC-2070
50-Pin I/O Connectors
50-Conductor cable
Figure 2-5. Direct Connection between an MIO-16 Board and the SC-2070 Board
If any signal conditioning of the digital I/O ports with the National Instruments SC-206X Series boards
is desired, then the SC-2050 cable adapter board must be used with the DAQ boards listed in
Table 2-2. Figure 2-6 shows a connection using the SC-2050 cable adapter board.
MIO-16
SC-2050
Digital I/O
SC-2070
SC-206X Series
or
8-Channel SSR
26-Conductor Cable
50-Conductor Cable
Figure 2-6. Connection between an MIO-16 Board and the SC-2070 Board
via the SC-2050 Board