ALWAYS wear safety glasses. Every day eyeglasses only have impact 
resistant lenses. They are not safety glasses. 
READ AND UNDERSTAND ALL SAFETY WARNINGS & PROCEDURES 
BEFORE OPERATING LIFT. 
POST THESE SAFETY TIPS WHERE THEY WILL BE A CONSTANT 
REMINDER TO YOUR LIFT OPERATOR.  FOR INFORMATION SPECIFIC TO 
THE LIFT, ALWAYS 

REFER TO THE LIFT MANUFACTURER’S MANUAL. 

 

Improper installation can cause accelerated 
wear, resulting catastrophic failure which 
may cause property damage and / or bodily 
injury. Manufacturer will assume no liability 
for loss or damage of any kind, expressed 
or implied, resulting from improper 
installation or use of this product. Read this 
installation manual in its entirety before 
attempting to install or operate the lift. 

 
SELECTING SITE: 

Before installing your new lift, check the following. 

 
OVERHEAD OBSTRUCTIONS

: The area where the lift will be located should be 

free of overhead obstructions such as heaters, building supports, electrical lines 
etc. 

 
FLOOR REQUIREMENTS: 

Visually inspect the site where the lift is to be 

installed and check for cracked or defective concrete. This lift must be installed 
on a solid level concrete floor with no more than 2 degrees of slope. A level floor 
is suggested for proper installation and level lifting. If a floor is of questionable 
slope, consider a survey of the site and/or the possibility of pouring a new level 
concrete slab. This lift is designed to be installed on a minimum of 4” thick, 
3500psi, steel reinforced concrete. Do not install this lift on asphalt, wood, or any 
other surface other than described. This lift is only as strong as the foundation on 
which it is installed. 

DO NOT 

install this lift outdoors unless special consideration has been made to 

protect the power unit from weather conditions. 

DO NOT 

begin installation with lift close to wall. It is necessary to leave adequate 

clearance for installing safety linkage rods. Allow 60” for clearance. 

(See Fig.1) 

 

Содержание NSS-8000

Страница 1: ...NSS 8000 Installation Manual ...

Страница 2: ...5 hours Do not rush It is better to spend a few extra minutes and do the job right If you will avoid the following common mistakes your lift will go together easily and serve you well for many years 1 Do not attempt to use the power unit to extend your cylinder This must be done manually 2 If you do not know how to wire your motor get professional help ...

Страница 3: ...ure to read these instructions may result in injury to user other people within the area of the lift or vehicles We are not responsible for any injury or damage as a result of neglecting to carefully read and follow these instructions Always lock the lift in place before going under the vehicle Never allow anyone to go under the lift when raising or lowering INSPECT your lift daily Never operate i...

Страница 4: ... use to protect the operator from electric shock DANGER The power unit used on this lift contains high voltage Disconnect power at the receptacle before performing any electrical repairs Secure plug so that it cannot be accidentally plugged in during service WARNING RISK OF EXPLOSION This equipment has internal arcing or sparking parts which should not be exposed to flammable vapors This machine s...

Страница 5: ...ocated should be free of overhead obstructions such as heaters building supports electrical lines etc FLOOR REQUIREMENTS Visually inspect the site where the lift is to be installed and check for cracked or defective concrete This lift must be installed on a solid level concrete floor with no more than 2 degrees of slope A level floor is suggested for proper installation and level lifting If a floo...

Страница 6: ...river Socket And Ratchet Set 7 16 1 1 8 Tape Measure 25 Foot Minimum Hex Key Allen Wrench Set Needle Nose Pliers COLUMN CROSSRAIL INSTALLATION Lay down rear columns Position the crossrail at the top of the two columns both cross rails are the same Install the crossrail in the column by sliding the plastic guide blocks into the column channel The safety latch must be positioned with bevel side to t...

Страница 7: ... bolts with 1 2 washers and nuts placed hand tight Now install the offside track and again secure with ramp brackets wheel stops with 1 2 x 4 bolts and nuts After both tracks are installed tighten all bolts 1 2 x 4 bolts torque 45 ft lbs Find the leg caps 4 each 1 2 x 7 bolts 4 each 1 2 x 1 1 4 bolts 4 each 1 2 nuts 8 each and 1 2 flat washers 16 each holes for cable face towards the center of the...

Страница 8: ...o back end of the cylinder opposite the cylinder rod Safety latch linkage rod should pass through guide tubes on underside of track Install the 1 2 x 126 straight safety latch linkage rod into the main side track from the opposite end The rod should pass through two guides on the underside of the main side track Attach the 71 hose to the fitting on the power unit Attach the other end of the 71 hos...

Страница 9: ...heck inside the switch box to make sure you use the correct colored wire for ground Also check the outside plate to make sure your motor is the proper voltage Your motor will be for 110 volts unless you specifically ordered a 220 volt motor Initial Operation Press the UP SWITCH on the power unit Raise the lift slowly until all the slack in the cables is taken out Raise the lift until the safety la...

Страница 10: ...for full engagement in the rack on each leg 3 To lower push UP button to raise rotate latch release rod handle and hold push rod handle on power unit to lower Warning Make sure all four latches release if not STOP raise higher until latch is clear if it does not work now the hemin tie rod end on that latch needs adjustment 4 Any hydraulic oil leakage unusual noise or excessive wear must be fixed b...

Страница 11: ...11 ...

Страница 12: ...12 ...

Страница 13: ...13 ...

Отзывы: