If necessary, use dedicated handling equipment (cranes, ropes, trolleys), using the lifting points provided in the
product.
During handling it is recommended to:
• Handle with care
• keep away from suspended loads
• always wear accident prevention equipment
• be careful not to damage electrical cables
Do not handle the product using electrical cables as lifting gear.
WARNING
Failure to follow the instructions may result in damage to the product, the system in which it is
installed and, in the worst cases, damage to property or persons with even fatal consequences.
4.4. Storage
The product must be stored in its packaging in a dry place, without sudden changes in humidity and temperature
and protected from mechanical (weights, vibrations), thermal and chemical agents.
The temperature of the storage environment must be between -20°C (-4°F) and 70°C (+158°F) with a maximum
relative humidity of 85% (non-condensing).
If the product remains in stock for more than 24 months from the manufacturing date shown on the packaging, it is
necessary to check the mechanical integrity of its parts and supply power to it at least once every 12 months.
If the product is put back into storage after it has been used, it is advisable to contact the manufacturer for further
information on storage.
In particular, store the pump in a place with a minimum temperature that is not below 4 °C (40 °F).
TIP
For more information contact the dealer or technical support at [email protected] or by opening a
support ticket on the portal service.nastec.eu
5. Technical features
5.1. Technical Data
Electrical specifications by model:
Model
Vin DC [VDC]
Vin AC [VAC]
Vnom **
I in [A]
P2 [kW]
P1 [kW]
Max RPM
SUND 50
90 - 400
1 x 90 - 265
90 V
Max 12 A
3,5 A (230 VAC)
0,55
0,8
3600
**Minimum voltage for nominal performances.
General electrical specifications:
Power supply frequency
50 - 60 Hz (+/- 2%)
EMC compliance
EN61800-3 C1
Winding insulation class
Class F
WARNING
If the device is powered by a generator set, make sure that:
• The generator set supplies the required voltage and is equipped with an electronic voltage regula-
tor (AVR).
• The power of the generator set is at least 50% higher than the rated electrical power of the device.
• The device is connected to the generator set only after the same has started.
• The device is disconnected from the generator set before the same is stopped.
• The device is not connected to the generator set when it is about to shut down due to lack of fuel.
Environmental specifications: