A flanged hole simulating
an abdominal incision
for the insertion of a
feeding tube is included
on the upper torso for
performing lavage and
gavage . (See Figure 25) .
Inside the upper torso
is a reservoir bag with a
maximum capacity of 200 cc, which is attached to
the underside of the gastrostomy opening with a
two-part coupler . Access the bag by:
1 . Reaching through the genital opening in the
pelvis, on the left side of the torso .
2 . Remove the bag by
pushing in on the
L-shaped button and
pulling it straight away .
(See Figure 26 and
inset) .
Note: In some models,
the waist pin will need
to be removed for easier
access . Not easy to remove
the waist connection, it
no longer a pin but two
individual attachment points
Set Up
Gastrostomy Care Lavage and Gavage
Gastrostomy Care Lavage and Gavage
Fig 25.
Fig 26.
To attach the bag:
1 . Push the coupler body (with bag attached)
onto the coupler insert (part with the black
O-ring) that is protruding from the underside of
the gastrostomy inside the upper torso of the
manikin . You will hear a slight snap when the
connection is complete .
2 . Test the connection by gently pulling on the
coupler body to ensure it is locked .
Note: The gastrostomy feature is designed for
use with a 16 French Gastrostomy Tube . It is
recommended that the tip of the feeding tube is
well lubricated before inserting .
3 . Ensure the reservoir is straight and flat before
attempting to simulate feeding with water .
Note: Water only should be used to perform
feeding procedures .
4 . Lubricate the end of the feeding tube and gently
insert through the flanged hole .
5 . Upon completion of the exercise, remove
genitals, remove the reservoir, drain the liquid
from the reservoir bag, and rinse the bag .
6 . Ensure the bag is clean and dry prior to storing it
back inside the torso . Wipe any residual lubricant
with warm water and a soft cloth prior to storing
the manikin .
14
Содержание DANi LF04500