Oral and Nasal Lavage,
Gavage, and Suctioning
Access to the stomach
is provided through the
mouth and both nostrils .
The internal stomach
reservoir bag has a 200 cc
capacity . The head
should be connected to
the stomach reservoir bag green) and NOT the
intubation air bladder bag yellow) . (See Figure 7) .
Lubricate feeding tubes generously prior to
inserting through mouth, nose, or nostrils by using
the Pump Spray Lubricant included . Only water
should be used in tube feeding exercises . Ensure
the upper torso of the manikin is slightly elevated
to prevent water backflow into the head of the
manikin . Introduce water only using standard
facility procedures and materials .
Following the procedure,
empty the stomach .
Water may be removed
by suctioning or removing
the stomach reservoir
bag by disconnecting 2
VELCRO
®
straps and white
disconnect and then
draining it into a sink or
basin . (See Figure 8) .
Note: Ensure the manikin’s torso remains elevated
when the stomach reservoir bag contains water
to continue to prevent backflow into the head
of the manikin . Features included with LF04502/
LF04502M, LF04504/LF04504M, and LF04504EX/
LF04504MEX .
Fig 7.
Set Up
Lavage / Gavage / Suctioning / Nasogastric / Carotid Pulse
Fig 9.
Fig 11.
Fig 10.
To remove the Stomach
Reservoir Bag:
1 . Remove the head by
disconnecting the
snaps on the head
skin, around the neck,
rotating the head 45
degrees, and aligning
the head with the
notch on the neck ring
and pulling the head
up (See Figure 9) .
2 . Gently pull up head to
expose four tubes with
the stomach reservoir
bag connected at the
end . (See Figure 10) .
3 . Unfasten the strap that holds the Stomach
Reservoir Bag and esophagus tube together and
depress button on the quick disconnect feature
of the bag . (See Figure 11) .
Following completion of the procedures,
completely drain the stomach reservoir and allow
drying prior to reattaching and storing inside the
manikin . Wipe any residual lubricant with warm
water and a soft cloth .
Carotid Pulse
Attach pump bulb to Carotid tube exiting the rear
neck . (See Figure 12) . Pump bulb to simulate pulse
at the pulse points of the Carotid (See Figure 13) .
Pulse points are present on both sides .
Fig 12.
Fig 13.
Fig 8.
Disconnect
Velcro
Velcro
10