background image

DANi

Patient Care Trainer 

LF04500/LF04500M

Patient Skills Trainer 

LF04502/LF04502M

Patient Simulator 

LF04504/LF04504M

Patient Simulator, Export 

LF04504EX/LF04504MEX

INSTRUCTION MANUAL

Содержание DANi LF04500

Страница 1: ...DANi Patient Care Trainer LF04500 LF04500M Patient Skills Trainer LF04502 LF04502M Patient Simulator LF04504 LF04504M Patient Simulator Export LF04504EX LF04504MEX INSTRUCTION MANUAL...

Страница 2: ...my Care Lavage and Gavage 14 Male Catheterization 15 Foreskin Application Prostate Examination 16 Female Catheterization 17 Enema Administration 18 Female Cervical Exam 18 Suprapubic and Urinary Cathe...

Страница 3: ...l patient for lifting and carrying Each version is affordable and durable with upgradable items DANi Teen Young Adult Patient Care Trainer General patient care daily living assistance simulation platf...

Страница 4: ...uded Soft Male and Female Genitalia Normal and Cancerous Moles Stage 1 Sacral Ulcer Bandaging and Wound Dressing Recommended bandages Silicone Adhesive Bandages Patient Positioning fully articulated A...

Страница 5: ...stration Left Blood Pressure Arm with Radial Pulse Injection Sites arms thigh right side buttocks supporting IM and sub cutaneous injections Gastrostomy Procedures lavage gavage tube placement Nasogas...

Страница 6: ...re Urinary Catheter Care No aux equipment Stomas Standard Arms with Injection Sites Support for Oxygen Administration Left Blood Pressure Arm Option Advanced Skills Injections Sites Gastrostomy Proced...

Страница 7: ...g Self Harm LF04527 Bruising Drug Use LF04526 List of Components Female Genitalia SANE LF04514 Light LF04514M Medium DANi Teen Young Adult Patient Simulator LF04504 LF04504M includes monitors DANi Tee...

Страница 8: ...Hygiene Tooth brushing should be simulated without water or any cleaning agents to avoid leaking into the head of the manikin and to simplify cleanup Teeth cannot be flossed Note All Versions of DANi...

Страница 9: ...ment Features included with LF04502 LF04502M LF04504 LF04504M and LF04504EX LF04504MEX Fig 6 Set Up Ear Care Bath Washing Tracheostomy Care Ear Care Both ears may be irrigated Using water to perform e...

Страница 10: ...ntinue to prevent backflow into the head of the manikin Features included with LF04502 LF04502M LF04504 LF04504M and LF04504EX LF04504MEX Fig 7 Set Up Lavage Gavage Suctioning Nasogastric Carotid Puls...

Страница 11: ...loop Insert the tubes back into the torso of the manikin and replace the head on the torso See Figure 14 2 Lubricate nasogastric devices and supplies being used with the Pump Spray Lubricant provided...

Страница 12: ...ing a laryngoscope blade As with a real human See Figure 21 damage can be caused if improper forces and techniques are used Damaged caused by improper use will void the warranty Note There is no crico...

Страница 13: ...a reservoirs See Figure 22 1 Remove the genitalia and reach through the genital cavity It is recommended to suction the fluid from the bag prior to removal to prevent spillage when removing for cleani...

Страница 14: ...coupler body with bag attached onto the coupler insert part with the black O ring that is protruding from the underside of the gastrostomy inside the upper torso of the manikin You will hear a slight...

Страница 15: ...Fig 30 Fig 27 Note The Fluid Supply Stand is not included Use distilled water or follow instructions on the Simulated Urine 4 Lubricate the catheter being used with the Pump Spray Lubricant provided S...

Страница 16: ...te examination Following the procedure rinse the rectum with warm water and allow to dry prior to storing Note The male genital insert does not have the capacity for enema administration Must use fema...

Страница 17: ...enitalia to remove any residual lubricant Fluids should be drained and the reservoir emptied after every use Ensure the reservoir is clean and dry prior to storing Female Catheterization Enema Inserti...

Страница 18: ...enema reservoir holds up to 200cc of fluid Fig 41 Set Up Enema Administration Female Cervical Examination Features included with LF04502 LF04502M LF04504 LF04504M and LF04504EX LF04504MEX The female...

Страница 19: ...ubricate the catheter being used with the Pump Spray Lubricant provided The catheter should be well lubricated and force should not be used when placing the tube After completion of the exercise 1 Clo...

Страница 20: ...splay window are three buttons Menu Gap and Calibrate Blood Pressure Arm Features included with LF04502 LF04502M LF04504 LF04504M and LF04504EX LF04504MEX Installing the Batteries 1 Take the Blood Pre...

Страница 21: ...will display in the Electronic Control Unit window See Figure 55 6 Use the up or down arrow keys located to the right of the menu button to adjust the diastolic pressure Note The systolic and diastoli...

Страница 22: ...e pulse will automatically turn off when the cuff is inflated and surpasses the systolic set point It will turn on when the cuff is deflated 20 mmHg below the diastolic set point This function allows...

Страница 23: ...and the main menu window will be displayed Set Up Blood Pressure Arm Fig 60 Fig 61 Performing a Blood Pressure 1 Verify the pressure line tubing from the sphygmomanometer and the audio line from the a...

Страница 24: ...with the assembled sphygmomanometer 3 Obtain a new sphygmomanometer 4 Using a scissors carefully cut the tube of the sphygmomanometer about 2 from the gauge See Figure 62 5 Take the T fitting and inse...

Страница 25: ...he pint bottle containing the synthetic blood concentrate with distilled water 2 Close the clamp on the IV tubing and pour the synthetic blood into one of the provided fluid supply bags This will be I...

Страница 26: ...t IV needle or butterfly 7 To start the IV flow open the clamps on both IV Bags A and B Proof of proper procedure will be evidenced by the flow of fluid from IV Bag A Control flow rate with the clamp...

Страница 27: ...edures and ensure clamps are open on appropriate fluid supply IV bags and or shoulder tubes 2 Look over your equipment prior to use IV tubes will kink at the clamp site with repeated use Routinely mov...

Страница 28: ...aining the shoulder joint to the arm 2 Peel the skin down and remove from arm See Figure 69 3 Apply baby powder to the interior of the replacement skin and pull onto the arm 4 The key feature needs to...

Страница 29: ...recautions 1 This synthetic blood is specially formulated to be compatible with the self sealing veins and plastics used in manufacturing the injectable training arm 2 NEVER use synthetic blood for in...

Страница 30: ...eries into SmartScope and 2 AAA batteries into the remote control The compartments are marked as to the positions of the batteries or 4 Press the red power button on the remote control This turns on t...

Страница 31: ...e speaker cord into the speaker jack on top of the SmartScope box 3 Plug the amplifier speaker into the 110V or 220V power source 4 When the speaker is connected the SmartScope earpieces will not work...

Страница 32: ...ic presystolicmurmurs loud1stsound 5 Holosystolic Murmur Normal Normal Normal Normal Patienthasmitralregurgitation frequent prematureventricularcontractions Murmuriscrescendo decresendowithlate peakin...

Страница 33: ...i Ronchi Ronchi Ronchi 8 Stridor Stridor Stridor StridorLowerVolume StridorLowerVolume 9 Cavernous Cavernous Cavernous Cavernous Cavernous 10 Bronchovesicular Tracheal Bronchovesicular NormalVesicular...

Страница 34: ...en opening on the foot sleeve See Figure 83 Proper Application Shown See Figure 84 Set Up Pressure Injury Wounds Set Up Edema Edema Features included with LF04502 LF04502M LF04504 LF04504M and LF04504...

Страница 35: ...oid imlabworld com heartisensestudent Apple Device https apps apple com us app cpr add on kitinstructor id1203164623 https apps apple com us app cpr add on kitstudent id1400115591 Powering on CPR Moni...

Страница 36: ...Set Up Identifying Parts and Consumables 36 36 20 22 23 19 21 1 7 6 25 26 4 29 30 31 34 33 37 39 38 41 42 43 40 44 46 35 36 27 28 32 14 16 17 18 15 9 3 5 12 13 2 11 10 Arm Skin 24 45...

Страница 37: ...t Leg Skin Medium 16 LF04518 Right Arm Skin Light LF04518M Right Arm Skin Medium 17 LF04519 Left Arm Skin Light LF04519M Left Arm Skin Medium 18 LF04521 Torso Skin Light LF04521M Torso Skin Medium 19...

Страница 38: ...use Cautions Solvents or corrosive materials will damage the simulator Never place the simulator on any kind of printed paper or plastic These materials will transfer indelible stains Ball point pens...

Страница 39: ...YEARS 5 Up to 5 years warranty...

Страница 40: ...Nasco Healthcare 16 Simulaids Drive Saugerties NY 12477 1 833 NASCOHC 627 2642 info nascohealthcare com www nascohealthcare com PC 101038 02 23 2023 Nasco Healthcare...