background image

Yrittäjäntie 14, FI-27230 Lappi  •  tel. +358 0207 416 740  •  fax +358 0207 416 743  •  www.narvi.fi

18

FI

Narvi Black 

16 / 20 / 24 / 20 VS

Introduction

Thank you for having chosen our continuous burning  Narvi 
Black sauna heater. To make the most of your sauna heater 
please read the manual carefully before you start installing 
and using it and keep the manual for future reference. This 
user manual contains technical data of your sauna heater 
and installation, use and maintenance instructions.
 
The product is only meant to be used as a sauna heater 
and for heating the sauna. Do not modify the design of 
the sauna heater and use only spare parts and accessories 
recommended by the manufacturer. The data plate includ-
ed in the delivery of the sauna heater must be glued on the 
sauna heater, preferably on the lower part of the cover of 
the sauna heater.

Do not heat the sauna heater if you lack sufficient knowl-
edge, if you are not allowed to use sauna because of your 
health condition or you are under the influence of sub-
stances causing intoxication. Sauna heaters must not be 
used by underage people. Do not leave children in the 
sauna without supervision. A sauna is not meant for drying 
clothes.

Narvi Black sauna heater

16

20

20 VS

24

Height (mm)

760

760

760

760

Adjustment range ± (mm)

15

15

15

15

Width (mm)

400

480

480

550

Depth (mm)

500

500

660

500

Diameter of the connective flue (mm)

119

119

119

119

Distance of the bottom edge of the connective 
flue from the floor (mm)

555

555

555

555

Central point of the connection from the above 
from the rear edge of the sauna heater (mm)

115

115

115

115

Weight (without stones, kg) 

59

65

77

68

Weight of the stones, 10–15 cm (kg)

50

60

60

80

Volume of the water tank

-

-

22 l

-

Size of the steam room (m³)

8–16

10–20

10–20

12–24

Thickness of the cover of the furnace (mm)

10

10

10

10

Flue gas mass flow (g/s)

16,3

16,2

16,2

16,0

1.1 Technical data

EN

Follow the instructions!

Содержание Black 16

Страница 1: ...16 20 24 20 VS Monterings bruks och sk tselanvisning EN Narvi Black 16 20 24 20 VS Installation user and maintenance instructions DE Narvi Black 16 20 24 20 VS Installations Betriebs und Wartungsanle...

Страница 2: ...Anslutning till skorstenen 13 3 4 Montering av luckan och ndring av luckh ngning 14 SE Inneh ll 1 1 Technical data 18 2 Before you install the sauna heater 19 2 1 Steam room 19 2 2 Substrate 19 2 3 S...

Страница 3: ...Schornstein 29 3 4 Anbringen der T r und ndern der ffnungsrichtung 30 3 5 Installation des Hahns Modelle mit Wassertank 20 VS 30 3 6 Saunasteine 30 4 Betrieb des Saunaofens 31 4 1 Heizmaterial 31 4 2...

Страница 4: ...kaaseen suositeltu paikka on kiukaan vaipan alaosa l k yt kiuasta jos ep ilet kiukaank ytt taitojasi tervey dentilasi sopivuutta saunomiseen tai jos olet huumaavien aineiden vaikutuksen alaisena Alaik...

Страница 5: ...alla kuuluu k ytt Kota asennusalustaa joka suojaa lattiaa vesieristemateriaaleja ja lattial mmityskaa peleita tai putkistoja kiukaan l mp s teilylt 2 3 Suojaet isyydet Kiukaan sijoittamisessa on otett...

Страница 6: ...esil mmitys 3 1 Esil mmitys Ennen k ytt nottoa ja kivien asettamista on kiuas l m mitett v suoja aineiden poistamiseksi Mahdolliset suo jamuovit ja tarrat poistetaan ennen esil mmityst Esi l mmitys t...

Страница 7: ...siin on iso t ytt aukko Vesis ili n tilavuuden n et kohdasta 1 1 Hana asennetaan kiukaan asennuksen yhteydess joko kiukaan vasemmalle tai oikealle puolelle Kuva 5 Laita hana halutulle puolelle siten e...

Страница 8: ...t p st j ja palaminen on puhtaampaa Kiukaan tehoa s det n tuhkalaatikon avulla Tuhkalaa tikon ollessa kiinni on kiukaan teho pienimmill n ja pala misaika vastaavasti pitk Jos kiuas pit kovaa huminaa o...

Страница 9: ...t kylm t t ytyy ennen k ytt tarkistaa kiuas korroosiovaurioiden varalta ja ett hormi on ehj Aloita l mmitt minen hyvin varovasti ja hitaasti pienell m r ll puita ettei hormi vaurioidu H iri tilanteess...

Страница 10: ...n silloin kun k ytt asennus ja huolto ovat kiukaan ohjeistuksen mukaisia Takuuaika alkaa siit kun tavara on luovutettu loppuk yt t j lle Toimittaja ei kuitenkaan takuun puitteissa eik muu toinkaan vas...

Страница 11: ...tas p bastuugnen helst l ngst ner p bastuugnens mantel Elda inte i bastuugnen om du inte har tillr cklig kunskap f r det om ditt h lsotillst nd inte till ter bastubad eller om du r p verkad av berusni...

Страница 12: ...bastuugnen 2 3 S kerhetsavst nd Vid montering av bastuugnen m ste vissa s kerhetsav st nd f ljas Underl tenhet att f lja s kerhetsavst nden kan medf ra brandrisk Vid behov kontakta ditt lokala r ddnin...

Страница 13: ...bort resterna av anv nda skyddsmedel Allra f rst m ste all eventuell skyddsplast och dekaler avl gsnas F ruppv rmning m ste utf ras p ett icke ant ndligt underlag utomhus eftersom f rgen avger skadli...

Страница 14: ...modeller med vattenbeh llare 16VS 20VS 24VS Vattenbeh llaren i bastuugnens front har ett stort p fyllningsh l Vattenbeh llarens volym framg r av avsnitt 1 1 Kranen monteras i samband med bastuugnens i...

Страница 15: ...itar figur 9 T ndning uppifr n minskar avgaser och ger en renare f rbr nning Draget i eldstaden kan regleras med hj lp av askl dan Med askl dan st ngd r draget som minst och f rbr n ningstiden som l n...

Страница 16: ...stenen inte har anv nts p l nge eller vid kallt v der b r man alltid kontrollera innan eldning att skorstenen r hel och bastuugnen fri fr n rostskador B rja elda mycket f rsiktigt med liten m ngd ved...

Страница 17: ...d konsumentskyddslagen Garantin omfattar sedvan ligt familjebruk om bastuugnen anv nds monteras och underh lls i enlighet med angivna instruktioner Garantitiden b rjar g lla vid varans verl mnande til...

Страница 18: ...not heat the sauna heater if you lack sufficient knowl edge if you are not allowed to use sauna because of your health condition or you are under the influence of sub stances causing intoxication Saun...

Страница 19: ...OF COMBUSTIBLE MATERIAL OR A TILED FLOOR UNDERFLOOR HEATING A Kota installation base must be installed under the sauna heater which will protect the floor moisture barrier and un derfloor heating pip...

Страница 20: ...safety clearances stipulated in the in stallation manual of the smoke flue shall be followed The minimum recommended diameter of a modular smoke flue is 120 mm The weight of the smoke flue must not c...

Страница 21: ...or adjusting the height There must be an air gap of at least 25 mm between the sauna heater and the floor Use a spirit level to check if the sauna heater is level 3 3 Connection with the smoke flue Th...

Страница 22: ...large opening for filling it For the water volume see clause 1 1 The faucet is installed when the sauna heater is installed either on the left or right side of the sauna heater Figure 5 Place the fauc...

Страница 23: ...lated with the ash drawer If the ash drawer is closed the power of the sauna heater is at its lowest and the burning time is longer If the sauna heater soughs too much reduce the draft To do this clos...

Страница 24: ...oper order and that there are no corrosion damages on the sauna heater Start heating very slowly and with small quantity of firewood so that not to damage the smoke flue In case of malfunction stop th...

Страница 25: ...n Narvi Black sauna heaters warranty period is two years The war ranty covers normal family use provided use installation and maintenance meet the requirements stipulated in the instructions The warra...

Страница 26: ...n den unteren Teil der Abdeckung des Saunaofens Heizen Sie den Saunaofen nicht wenn Sie keine ausreichen den Fertigkeiten dazu besitzen Ihr Gesundheitszustand das Saunieren nicht zul sst oder falls Si...

Страница 27: ...a Installationsunterlage vor der W rmestrahlung des Saunaofens gesch tzt werden FUSSBODEN AUS ENTFLAMMBAREM MATERIAL ODER FLIESEN FUSSBODEN UND FUSSBODENHEIZUNG In diesem Fall muss die Kota Installati...

Страница 28: ...er Installationsanleitung des Schornsteins entsprechenden Sicherheitsabst nde eingehalten werden Der empfohlene Mindestdurchmesser des Elementschornsteins betr gt 120 mm Das Gewicht des Schornsteins d...

Страница 29: ...lt werden Zwischen dem Saunaofen und dem Fu boden muss ein Luftspalt von mindestens 25 mm bleiben berpr fen Sie die lotrechte Position des Saunaofens mit Hilfe einer Wasserwaage 3 3 Anschlie en an den...

Страница 30: ...des Wassertanks ist in Punkt 1 1 angef hrt Der Hahn wird im Laufe der Ins tallation des Saunaofens entweder links oder rechts vom Saunaofen angebracht Abbildung 5 Bringen Sie den Hahn an der erforderl...

Страница 31: ...zscheit gelegt werden Abbildung 9 Das Anz nden von oben verringert die Verschmutzung und das Verbrennen ist sauberer Der Zug des Herdes des Saunaofens kann mit Hilfe der Aschenschublade reguliert werd...

Страница 32: ...ie richtige Menge zur Erhal tung der W rme ist auf einmal 1 2 Holzscheite nachzule gen bzw insgesamt etwa 1 kg Holzscheite in jeder halben Stunde Die Aschenschublade kann auch etwas mehr zu geschoben...

Страница 33: ...Zeit der Aschenentfernung ge ffnet werden Der Zug nimmt den Staub mit 4 5 Wartung des Saunaofens Der Kamin der Verbindungszug und der Schornstein m s sen regelm ig gefegt werden Das Reinigen und Kehre...

Страница 34: ...ntiebescheinigung gilt der Beleg der Firma die das Produkt verkaufte Der Auftraggeber muss die Ware sofort nach deren ber gabe berpr fen Der Auftraggeber muss dem Lieferanten die Reklamation schriftli...

Страница 35: ...arvi fi FI Narvi Black 16 20 24 20 VS Narvi Black Narvi Black 16 20 20 VS 24 760 760 760 760 15 15 15 15 400 480 480 550 500 500 660 500 119 119 119 119 555 555 555 555 115 115 115 115 59 65 77 68 10...

Страница 36: ...Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi 36 FI 2 2 1 0 8 1 5 1 1 2 2 1 1 50 Kota Kota 2 3 2 3 1 1270 500 300 200 1000 50 25 50 300 7 1 30 30 120 30 Kota RU...

Страница 37: ...37 37 Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi FI 3 100 400 1000 2 3 2 50 2 4 600 12 600 120 2 5 6 10 m3 100 3 RU...

Страница 38: ...Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi 38 FI 3 3 1 1 1 2 3 2 25 3 3 Kota Kota Kota Kota 25 1 1 1 2 3 RU...

Страница 39: ...39 39 Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi FI 3 4 4 3 5 16VS 20VS 24VS 1 1 5 3 6 Kerisekivid Kota 10 15 1 1 5 4 RU...

Страница 40: ...Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi 40 FI 4 4 1 20 5 33 0 5 4 2 9 EN15821 90 C Narvi Black 16 20 20VS 24 1 4 3 5 3 5 4 5 20 20 20 20 1 3 3 3 3 5 10 10 10 10 2 2 5 2 5 3 5 10 1...

Страница 41: ...41 41 Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi FI 6 2 3 4 1 10 1 2 1 3 10 20 4 3 12 0 2 100 0 05 RU...

Страница 42: ...Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi 42 FI 6 4 4 4 5 4 6 5 RU...

Страница 43: ...43 43 Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi FI 7 Narvi Black 2 2 RU...

Страница 44: ...es to combustible materials Emission of combustible products Durability Surface temperature Release of dangerous substances Cleanability Flue gas temperature Mechanical resistance Thermal output and E...