2. Before you install the 

sauna heater

Before installing and using the sauna heater, make sure you 
are thoroughly familiar with the requirements for installing 
the sauna heater in the steam room. In case of questions 
and for additional information do not hesitate to contact 
the Rescue Board or a construction supervision authority. 
When installing fireboxes all local laws have to be followed, 
including those referring to local and European standards.

2.1 Steam room

If the walls of a steam room are made of uncovered glass, 
brick or concrete add 0.8–1.5 m3 per square meter of such 
wall and the final choice of the heater shall be made based 
on the sum of the area. If the heater is installed in a sauna 
that is normally not heated or the sauna is made of mas-
sive logs, multiply the sauna area by 1.5 and choose the 
heater based on this. The recommended minimum area of 
a steam room is indicated in clause 1.1. Please follow the 
values for the minimum area stipulated for a steam room.

We recommend choosing a sauna heater with slightly more 
power to ensure proper heating of the sauna and to avoid 
heating the sauna heater to its upper limit. Slightly stronger 
power ensures a longer lifetime of the sauna heater and 
provides better steam thanks to a greater quantity of 
stones.

2.2 Substrate

A firebox must be installed on the floor with sufficient 
load-bearing capacity. The durability of the floor must be 
checked especially carefully, when the sauna heater is in-
stalled on a wooden floor. The weight of the sauna heater 
is shown in clause 

1.1. 

If the existing floor does not meet 

this prerequisite, suitable measures (e.g. load distributing 
plate) shall be installed to achieve it.

 

CONCRETE FLOOR 

The sauna heater may be installed directly on a concrete 
floor, which is at least 50 mm thick. If underfloor heat-
ing cables or pipes are located under the sauna heater, a 
Kota installation base must be used to protect them from 
the sauna heater’s thermal radiation.

FLOOR MADE OF COMBUSTIBLE MATERIAL OR A TILED FLOOR, UN-
DERFLOOR HEATING

A Narvi installation base must be installed under the sauna 
heater, which will protect the floor, moisture barrier and un-
derfloor heating pipes or cables from the thermal radiation 
of the sauna heater.

 

2.3 Safety clearances

When installing the sauna heater, safety clearances must 
be taken into account. Ignorance of safety clearances 
causes a fire hazard. If required, additional information 
can be obtained from the regional branch of the rescue 
board.

2.3.1 Structure made of combustible materials

The safety clearances are the minimum allowable dis-
tances between the sauna heater and structures made of 
combustible materials. Please observe the stipulated re-
quirements regarding walls, floors, sauna benches, other 
inventories and storage areas of firewood!

Structure

Safety clearance, mm

Top surface

NC 16

NC 20

NC 24

1250

1225

1200

Front surface

500* 

Side surface

150

Back surface

150

*We recommend leaving 1000 mm maintenance area in 
front of the sauna heater.

Rear and side safety distances can be shortened by using 
Narvi protective wall shields. Our dealers can provide more 
info regarding suitable safety walls for sauna heaters.

Protecting a wall made of combustible material

Figure 3

. If the sauna heater is installed on a floor made of 

combustible materials, an installation base must be used. 
A piece of sheet metal must be installed in front of the in-
stallation base, which extends at least 100 mm over the 
sides of the heater hatch and at least 400 mm in front of 
the sauna heater. The sheet metal edges facing the sauna 

Содержание NC20

Страница 1: ...lto ohje 3 2022 SE Narvi NC 16 20 20 VS 24 bastuugnar Monterings bruks och sk tselanvisning EN Narvi NC 16 20 20 VS 24 sauna heaters Installation user and maintenance instructions DE Narvi NC 16 20 20...

Страница 2: ...gning 15 3 5 Montering av kran modeller med vattenbeh llare NC 20 VS 15 3 6 Bastustenar 16 SE Inneh ll 3 7 Bastuugnens luftriktarplattor 16 4 Anv ndning av bastuugnen 17 4 1 Eldningsmaterial 17 4 2 El...

Страница 3: ...gsrichtung 31 3 5 Saunasteine 32 3 6 Anbringen des Tunnelhitzsteins 32 3 7 Luftleitplatten des Hitzsteins 32 4 Betrieb des Saunaofens 33 4 1 Heizmaterial 33 4 2 Heizen 33 4 3 Aufgusswasser 34 4 4 Entf...

Страница 4: ...k yt kiuasta jos ep ilet kiukaank ytt taitojasi tervey dentilasi sopivuutta saunomiseen tai jos olet huumaavien aineiden vaikutuksen alaisena Alaik inen henkil ei saa k ytt kiuasta eik lapsia tule j...

Страница 5: ...ial mmityskaa peleita tai putkistoja kiukaan l mp s teilylt 2 3 Suojaet isyydet Kiukaan sijoittamisessa on otettava suojaet isyydet huomi oon Suojaet isyyksien laiminly nti aiheuttaa palovaaran Tarvit...

Страница 6: ...riitt v n palamisilman korvausilman saan ti varmistettava Tulisijan kanssa samassa huoneessa tai tilassa toimivat poistoilmapuhaltimet saattavat aiheuttaa ongelmia Tuloilma aukot tulee sijoittaa site...

Страница 7: ...d n kiukaan p lt k ytet n Kota yhdyshormia tai Kota savuhormia P lt liitett ess voi yhdyshormin ymp rille asentaa my s Kota piippus ili veden l mmityst varten tai Kota kivikori Yhdyshormia ei saa asen...

Страница 8: ...p lle tulevat kerrokset riitt v n harvaan jotta ilma p see kiert m n kivien v list Litte t kivet ladotaan pystyasentoon Kivet eiv t saa tukkia ilma aukkoja tiiviisti eik kivi saa latoa keoksi kiukaan...

Страница 9: ...aan tehoa s det n tuhkalaatikon avulla Tuhkalaa tikon ollessa kiinni on kiukaan teho pienimmill n ja pala misaika vastaavasti pitk Jos kiuas pit kovaa huminaa on vetoa v hennett v asettamalla tuhkalaa...

Страница 10: ...t ytyy ennen k ytt tarkistaa kiuas korroosiovaurioiden varalta ja ett hormi on ehj Aloita l mmitt minen hyvin varovasti ja hitaasti pienell m r ll puita ettei hormi vaurioidu H iri tilanteessa lopeta...

Страница 11: ...kiukaan ohjeistuksen mukaisia Takuuaika alkaa siit kun tavara on luovutettu loppuk yt t j lle Toimittaja ei kuitenkaan takuun puitteissa eik muu toinkaan vastaa virheist jotka ilmenev t yli kahden 2 v...

Страница 12: ...tel Elda inte i bastuugnen om du inte har tillr cklig kunskap f r det om ditt h lsotillst nd inte till ter bastubad eller om du r p verkad av berusningsmedel Bastuugnen f r inte anv ndas av minder rig...

Страница 13: ...V AV ANT NDLIGT MATERIAL ELLER KLINKERGOLV MED GOLVV RME Anv nd Narvis monteringsplatta som skyddar golvet fukt sp rren och golvv rmens kablar eller r r mot v rmestr l ning fr n bastuugnen 2 3 S kerhe...

Страница 14: ...ten s n ra bastuugnen som m jligt Full god luftcirkulation i basturummet m ste garanteras ven under tiden n r man badar bastu s att fr nluften leds ut under bastulaven eller under d rren genom tillr c...

Страница 15: ...anv ndas f r bastuugnens bakanslutning till skorstenen Endast rak anslutningskanal utan f rl ng ningar f r anv ndas d kanalen kopplas bakom bastuug nen Om toppanslutning anv nds m ste antingen Kota an...

Страница 16: ...r sk ljas rena fr n eventu ell smuts innan de b rjar anv ndas St rre stenar l ggs l ngst ner i stenutrymmet med vriga stenar ovanp s att det finns tillr ckligt med luftutrymme mellan stenarna Platta...

Страница 17: ...gaser och ger en renare f rbr nning Draget i eldstaden kan regleras med hj lp av askl dan Med askl dan st ngd r draget som minst och f rbr n ningstiden som l ngst Om det h rs ett kraftigt brus fr n el...

Страница 18: ...vid kallt v der b r man alltid kontrollera innan eldning att skorstenen r hel och bastuugnen fri fr n rostskador B rja elda mycket f rsiktigt med liten m ngd ved f r att inte skada skorstenen Vid st...

Страница 19: ...vanligt famil jebruk om bastuugnen anv nds monteras och under h lls i enlighet med angivna instruktioner Garantitiden b rjar g lla vid varans verl mnande till slutan v ndaren Leverant ren tar inget ga...

Страница 20: ...nowl edge if you are not allowed to use a sauna because of your health condition or you are under the influence of substances causing intoxication Sauna heaters must not be used by underage people Do...

Страница 21: ...e it CONCRETE FLOOR The sauna heater may be installed directly on a concrete floor which is at least 50 mm thick If underfloor heat ing cables or pipes are located under the sauna heater a Kota instal...

Страница 22: ...e weight of the smoke flue must not cause load on the sauna heater The sauna heater should be con nected to a separate smoke flue A smoke flue made of bricks must be at least the so called half brick...

Страница 23: ...without extra parts can be used when the flue is connected from rear If the connection with the smoke flue is done from the above a Kota connective flue or Kota smoke flue must be used In case of con...

Страница 24: ...re placed in the bottom of the stone compartment and the rest are piled sparsely so that air can move freely between the stones Flat stones shall be stacked in upright position The stones must not blo...

Страница 25: ...duces pollution and ensures cleaner burning The power of the sauna heater can be regulated by the ash drawer If the ash drawer is closed the power of the sauna heater is at its lowest and the burning...

Страница 26: ...closing pan after heating check that there is no glowing coal in the firebox Otherwise fumes may be released in the sauna Carbon monoxide is an odourless and colourless toxic gas If you have not used...

Страница 27: ...supplier is not liable in any way for any defects within the framework of the warranty or other defects that appear later than two 2 years after the delivery of the goods to the client The supplier ma...

Страница 28: ...den Sie den Saunaofen nicht wenn Sie keine ausreichenden Fertigkeiten dazu besitzen Ihr Gesund heitszustand das Saunieren nicht erm glicht oder falls Sie unter Einfluss von berauschenden Substanzen st...

Страница 29: ...ichtbare Bedingung nicht erf llt m ssen geeignete Ma nahmen z B Lastver teilungsplatte installiert werden um dies zu erreichen BETONFUSSBODEN TDer Saunaofen kann direkt auf einen Betonfu boden ins tal...

Страница 30: ...teins betr gt 120 mm Das Gewicht des Schornsteins darf den Sau naofen nicht belasten Es wird empfohlen den Saunaofen an einen gesonderten Rauchkanal anzuschlie en Ein aus Steinen gesetzter Schornstein...

Страница 31: ...g von hinten angeschlossen wird Wenn der Anschluss zum Schornstein ber dem Saunaofen angebracht wird muss ein Kota Verbindungskanal oder Kota Schornstein benutzt werden Beim Anschluss oberhalb kann um...

Страница 32: ...me zum Entfernen von eventuellem Schmutz ge waschen werden Gr ere Steine werden auf den Boden des Steinraums gesetzt und auf diese die brigen Steine ausreichend locker so dass sich Luft durch die Ste...

Страница 33: ...Birkenrinde oder Papier ver wendet werden Z ndmaterial sollte zwischen die oberen Scheite gelegt werden und darauf k nnen zus tzlich noch einige Splitter oder ein d nnerer Holzscheit gelegt werden Ab...

Страница 34: ...ens oder des Schornsteins und Brandgefahr Man darf jedoch nicht l nger als 3 Stun den ununterbrochen heizen Danach muss der Saunaofen vor dem n chsten Heizen abgek hlt werden Wenn der Saunabesuch been...

Страница 35: ...gilt der Beleg der Firma die das Produkt verkaufte Der Auftraggeber muss die Ware sofort nach deren berga be berpr fen Der Auftraggeber muss dem Lieferanten die Reklamation schriftlich innerhalb von z...

Страница 36: ...NC Narvi NC 16 20 20 VS 24 780 800 740 820 15 15 15 15 500 540 590 580 580 580 570 580 119 119 119 119 595 595 545 635 150 150 150 150 72 76 80 82 10 15 50 60 50 80 23 l 3 8 16 10 20 10 20 10 24 10 1...

Страница 37: ...37 37 RU 2 2 1 0 8 1 5 1 1 2 2 1 1 50 Kota Narvi 2 3 2 3 1 1000 Narvi 3 100 400 NC 16 NC 20 NC 24 1250 1225 1200 500 150 150...

Страница 38: ...38 RU 1000 2 3 2 50 100 2 4 600 12 600 120 2 5 6 10 m3 100...

Страница 39: ...39 39 RU 3 3 1 1 2 3 2 25 3 3 25 1 1 3 4 7 3 5 NC 20 VS 1 1 8...

Страница 40: ...40 RU 3 6 Kota 10 15 1 1 3 7 NARVI NC16 NC20 NC20VS NC24...

Страница 41: ...41 41 RU 4 4 1 20 5 33 0 5 4 2 9 EN15821 90 C Narvi NC 16 20 20VS 24 1 3 3 5 3 5 4 5 20 20 20 25 1 2 3 3 3 5 10 10 10 25 2 2 2 5 2 5 3 5 10 10 10 10 6 7 7 8 5 33 0 5...

Страница 42: ...42 RU 2 3 4 1 10 9 1 2 1 3 10 20 4 3 12 0 2 100 0 05 4 4 4 5...

Страница 43: ...43 43 RU 4 6 5 6 7 Narvi 2 2...

Страница 44: ...2 Pa 16 kW 7 kg Pass Pass 387 C Narvi Oy 12 EN 15821 2010 Multi firing sauna stoves fired by natural wood logs for space heating in residential buildings Narvi NC20 VS Fire safety initiation risk to a...

Отзывы: