EN
W415-2034 / A / 10.18.19
35
venting installation
A.
Secure 5” restrictor to mounting plate using 2 screws (supplied).
B.
Remove baffl e by removing 1 screw from fi rebox. Set screw and baffl e aside.
C.
Align mounting plate clearance holes (4) over existing screws protruding into fi rebox. For ease of access,
ensure restrictor and mounting plate are installed with screws installed in Step A facing upwards
(into exhaust collar).
D.
Install 4 self-drilling screws (supplied) (2 per side).
E.
Reinstall baffl e using screw removed in step B.
note:
For ease of installation, the mounting plate was designed with 2 fi xed holes and 2 slotted holes.
MOUNTING
SCREWS
FIREBOX
TOP
MOUNTING
PLATE
BAFFLE
5” RESTRICTOR
TOP VIEW
1. MOST RESTRICTION
2. MODERATE RESTRICTION
3. LEAST RESTRICTION
EXHAUST COLLAR
FIREBOX TOP
#8 x ½ HEX HEAD
SHEET METAL
SCREWS
Vertical installations may display a very active fl ame. If this appearance is not desirable, the exhaust outlet may be
restricted with a Wolf Steel approved restrictor kit. This kit is not recommended for short vertical vent runs.
Depending on the model and/or year of your appliance, mounting holes may not exist.
5.5
restricting vertical vents
5.5.1 LV38-1 / LV50-2
5.5.2 LV62 / LV74
A.
If mounting holes exist, remove the screws from the fi rebox top, align the restrictor plate as illustrated and
secure.
B.
If mounting holes do not exist, align the restrictor plate as illustrated and secure using the two screws
(supplied).
C.
Ensure the plate will pivot at the slot up into the exhaust outlet.
D.
Depending on the amount of restriction desired, the restrictor plate can be left fl at for most restriction or
bent up for varying degrees of restriction.
1. Most restriction
2. Moderate restriction
3. Least restriction
Exhaust collar
Restrictor
Mounting
screws
Firebox top
Firebox top
Restrictor
Top view
#8x½ hex head
sheet metal screw