40.15
NOTE: More frequent cleaning may be required depending on pellet quality.
W415-1472 / 04.21.15
40
EN
10.3 SEMI-ANNUALLY (OR EVERY TWO TONS OF PELLET)
10.3.1 VACUUM
HOPPER
10.3.2
SOOT AND FLY ASH FORMATION
10.3.3
CLEAN THE VERTICAL EXHAUST DUCT
The more frequently you clean out the fl y ash, the more effi cient your
appliance will burn.
A.
Operate the appliance until the pellets run out, then open the hopper
and vacuum out the entire hopper.
The dust and any other debris near the bottom should be removed to
prevent excessive build-up.
40.8B
The products of combustion will contain small particles of fl y ash. The fl y ash will collect in the exhaust venting
system and restrict the fl ow of the fl ue gases. Incomplete combustion occurs during startup, shutdown, or
incorrect operation of the room appliance will lead to some soot formation which will collect in the exhaust
venting system. The exhaust venting system should be inspected at least once every year to determine if
cleaning is necessary.
40.9
A.
Pivot the viewing door wide open.
B.
Remove the one screw on each exhaust port located
on either side of the fi re box. Remove the exhaust port
doors and set aside on a non-combustible surface.
Insert a vacuum into the exhaust port holes and remove as
much fl y ash as possible from behind the left and right exhaust
manifolds. Do not use a household vacuum to clean the
appliance. We recommend that you use a shop vacuum that is
equipped with a fi ne dust fi lter or a vacuum specifi cally made
for ashes and soot. Using a vacuum which is not equipped with
a fi ne dust fi lter may clog and disperse fl y ash and soot into the
room.
NOTE: The appliance must be completely out before you vacuum the appliance. Live pellets, if
sucked into the vacuum will light the vacuum on fi re and may ultimately cause a house fi re.
Once clean, replace the exhaust port doors and secure with the screws.
40.17A
EXHAUST
PORT
Содержание NPI45
Страница 48: ...W415 1472 04 21 15 48 EN 67 20 29 58 41 38 43 44 63 57 60 6 11 3 NPI45 REPLACEMENT PARTS...
Страница 54: ...W415 1472 04 21 15 54 EN 14 0 SERVICE HISTORY 43 1...
Страница 55: ...W415 1472 04 21 15 55 EN 15 0 NOTES 44 1...
Страница 105: ...105 W415 1472 04 22 15 FR 46 29 50 34 50 52 46 51 45 47 48 49 49 13 21 30 44 43 56 6 11 2 PI CES DE RECHANGE DU NPS45...
Страница 106: ...106 W415 1472 04 22 15 FR 67 20 29 58 41 38 43 44 63 57 60 6 11 3 PI CES DE RECHANGE DU NPI45...
Страница 114: ...114 W415 1472 04 22 15 FR 15 0 NOTES 44 1...
Страница 115: ...115 W415 1472 04 22 15 FR 44 1...