3.3 STOVE MINIMUM CLEARANCE TO COMBUSTIBLES
Through the Wall Installations complete
with outside air
Interior Vertical Vents
3.3.1 STRAIGHT INSTALLATION
DO NOT INSTALL INTO ANY AREA HAVING LESS THAN 48" (1219mm) (CEILING TO APPLIANCE
BOTTOM, EXCLUDING HEARTH HEIGHT).
!
WARNING
Through the Wall Vents complete with outside air
Interior Vertical Vents
NOTE: If interior vertical pellet vent is used, the clearance to the back wall is determined by the
upward-turning elbow or "Tee". It will vary in depth depending on the brand of pellet vent used (it is
approximately 5" (127mm). Before placing the appliance, connect the elbow or "Tee" and allow for the
minimum 3" (76mm) clearance to the combustible wall.
3.3.2 CORNER INSTALLATION
2”
6”
Floor Protection
45°
2”
2”
6”
6”