20
W415-0771 / B / 08.10.09
6.0 SPECIFICATIONS OF FURNACE
Heating Capacity
Up to 118,000 Btu/hr Average (32 kw)
Working
voltage
220
Volt,
15
Amp
Running
modes: First
fi re mode
Low:
Low
heat
requirement
mode
High:
High
heat
requirement
mode
Idle:
To
keep
a
core
fi re going in the fi re pot and maintain
minimum heat in the house
Hot air blower
1800 cfm and quiet type (3060 m
3
/ hr)
Combustion air blower
150 cfm (255 m
3
/ hr)
Plenum Opening for hot air outlet
18” x 14” (457 x 356 mm)
Return air opening
18” x 14” (457 x 356 mm)
Dimensions - “Furnace”
25” (deep) x 24 ½” (width) x 51” (height)980 (deep) x 620
(width)
x
1290
(h)
mm
Dimensions overall (installed)
57” (deep) x 52” (width) x 51” (height) 1450 (deep) x 1300
(width)
x
1320
(h)
mm
Weight (overall)
770 lbs approx (350 kg)
Weight (main body only)
560 lbs (255 kg)
Flue pipe diameter
6” DIA. Class “A”, “L” or masonry with SS liner.
Flue gas temp @ 20” above furnace outlet
300°F Average 265 – 390°F depending on the run mode
Furnace Effi
ciency
80%
Fire pot material
9 Ga AISI 310 (inner shell)9 Ga AISI 304 (outer shell)
Hopper capacity
8 bags of corn (448 lb), 10 bags of pellet (400 lb)
Average daily consumption
2 to 15 lbs / hour
Average daily ash quantity
About ½ lb depending on the mode
Building size
Up to 3600 sq ft.