W415-0771 / B / 08.10.09

3.   Put about 3-4 cups of pellet at the bottom of fi re pot manually. It is always easier to start the fi re with pellet.
4.   Add some fi re gel to the pellets and mix it. You may also use solid type fi re starters. 
5.   Make sure that control panel is at off position.
6.   Use a match to start the fi re. You may keep the door open for a while, just to observe fi re going.
7.   Let the fi re continue by itself for a minute or two.
8.   Select corn as your fuel on the control panel when off.
9.   Turn on the control panel by pushing the on button for few seconds.
10.  Press the fi rst fi re button. Furnace will count down 500 seconds on this mode. Combustion air fan is 
       on to facilitate the fi rst fi re start-up. There will also be automatic corn feeding of 2 seconds at 200th 
       second. 

OCCURRENCE OF EXCESSIVE SMOKE DURING THE FIRST FIRE MODE IS NORMAL. THIS IS A TEM-

PORARY CONDITION AND IT WILL BE OVER IN A FEW MINUTES. PLEASE DO NOT PANIC.

11.  Furnace will automatically go into low mode at the end of 500 seconds, if no other mode selection is 
       made.
12.  You may close the door anytime now when you feel fi re is strong and will keep going.
13.  You may also choose to run your furnace at high mode depending on your heating requirements and 
       comfort level. You do not have to wait till end of fi rst fi re mode to select your furnace run mode.  
14.  It will take about 15-20 minutes for the fi re to stabilize and reach temperature. We do not recommend 
       stirring the content of fi re pot after the fi rst fi re.
15.  Now, just sit back and enjoy the heat.
16.  If room thermostat is connected you don’t have to choose any mode. Room thermostat will take over the 
       control of furnace.

6.7  FIRST FIRE (START UP) - WOOD PELLET BURNING

Assuming you have completed the installation of the furnace, connection of hot air outlet & return air to duct 
system, you can now put your furnace into operation. 

Please follow the instructions below, step by step.

1.   Fill the hopper with wood pellets. (Will take about 400 lbs –-- 10 x 40 lbs bags))
2.   Please keep in mind that auger is empty on the very fi rst operation. Use the manual fuel feed button on the 
      back of the control box to fi ll the auger fast.
3.   Put about 3-4 cups of pellet at the bottom of fi re pot.
4.   The rest of the operation is same as “corn burning” starting with #4.

Use of mix fuel: 
Corn & pellet mix use is permissible. Mixing corn with pellet will improve combustion of corn.  Fuel selection on 
the control panel may remain at “corn” when higher percentage of fuel is corn. 

6.8  OPERATION BY ROOM THERMOSTAT

Room thermostat takes over control of furnace when connected. Room thermostat will run the furnace at the 
mode needed, depending on your room temperature settings. (Please note that mode display on the control 
panel has no meaning when running by thermostat).

I M P O R T A N T   N O T E 

Depending on the preference for your location, room thermostats may be two different types. 
1.   Open contact type, 
2.   Close contact type.
When control panel is turned on, display will indicate the current setting for “room thermostat” on your furnace. 
Factory setting is for open contact type. Please see your installation manual regarding how to change the set-
ting.

Содержание NCPF-110

Страница 1: ...NG PLEASEREADENTIREMANUALBEFORE YOU INSTALL OR USE THIS HEATER If the heater is not properly installed a house fire may result causing personal injury or loss of life Contact local building or fire of...

Страница 2: ...D TOOLS 15 5 13 CONTROL PANEL ASSEMBLY 16 5 14 ROOM THERMOSTAT ASSEMBLY 16 5 15 LOCATION OF PRODUCT ID LABEL 16 5 16 FLUE CONNECTION 16 5 17 APPLICATIONS WITH VARIOUS CHIMNEYS 17 5 18 ELECTRICAL INSTA...

Страница 3: ...properly installed It is recommended that the pellet vent joints be sealed with a minimum 500 F 260 C silicone sealant Install according to the vent manufacturers instructions Your heater requires pe...

Страница 4: ...ow the instructions in this manual The exhaust system should be checked and cleaned a minimum once a year for any build up of soot or creosote Combustible materials such as firewood wet clothing etc p...

Страница 5: ...a safe furnace system and to prevent the build up of soot and creosote inspect and clean the unit and chimney prior to use and periodically during the burning season 10 DO NOT BURN GARBAGE OR FLAMMAB...

Страница 6: ...CORRUGATED BOX 2 2 A PALLET CONTAINING HOPPER BOX FAN BOX THE HOPPER BOX THE HOPPER 1 THE HOPPER LID 1 HOPPER BOTTOM SIDE PANELS 3 HOPPER LID HANDLES 2 SIDE PANELS SCREWS 6 FRONT DOOR HANDLES 2 CONTRO...

Страница 7: ...e corrugated box over the furnace Hopper box fan box are together packed on a pallet 2 Hopper box Open the box from top Remove hopper bottom side panels Pull the hopper up two people is recommended an...

Страница 8: ...e span of fans and receive high performance 15 Do not allow anyone to operate who is not familiar with its operation 16 Do not operate the furnace with doors open Keep all doors closed maintain all se...

Страница 9: ...can have clearance to ceilings reduced to 1 inch Flue exhaust pipe should continue as 6 up to the point it connects to chimney Chimney diameter to be 6 or larger if possible Floor must be non combust...

Страница 10: ...MANUAL BEFORE YOU INSTALL AND USE THIS HEATER FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH DO NOT INSTALL IN A SLEEPING ROOM WEAR GLOVES AND SAFETY GLAS...

Страница 11: ...ROM RIGHT FRONT 52 Two people are needed for the installation Position the main body of furnace at its predetermined location This assembly weighs about 660 lbs 300 kg and may require special moving e...

Страница 12: ...ee the figure on the right 5 2 HOPPER BOTTOM CLOSING OPENING SLIDE COVER Slide the metal plate into its place directly below the flange Make sure square holed section of metal plate aligns with flange...

Страница 13: ...threaded stand offs Take 2 bolts pass them through the holes and screw them with threaded stand offs Squareness of hopper to furnace can be adjusted while tightening stud bolts 5 6 FUEL WARNING SWITC...

Страница 14: ...to combustion air intake channel with the four bolts and nuts provided Connect the cable plug to its socket provided on the junction box Screw grounding cable to one of the bolts on the air chan nel s...

Страница 15: ...ady made FURNACE SIDE RETURN AIR SIDE 5 11 HOT AIR CONNECTION TO DUCT SYSTEM Hot air of the furnace comes out of 14 x 18 plenum box at the top of main unit Duct system of the house should be connected...

Страница 16: ...Install vent at clearances specified by the vent manufacturer Flue gas exhaust pipe is 6 diameter and made of steel There are two flue gas outlets provided on the flue box One is at the top the other...

Страница 17: ...e secured with at least 3 sheet metal screws All joints to be sealed with high temperature silicone A L vent 6 90 elbow B L vent connector flue gas steel pipe Existing masonry chimney Run 6 class L co...

Страница 18: ...ICAL INSTALLATION WARNING ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH LOCAL CODES AND WITH THE CURRENT CAS22 1 CANADIAN ELECTRICAL CODE OR WITH THE NATIONAL EL...

Страница 19: ...19 W415 0771 B 08 10 09 Napoleon NCPF 110 MOLEX CONNECTOR AT JUNCTION BOX Napoleon NCPF 110 MOLEX CONNECTOR UNDER CONTROL PANEL...

Страница 20: ...356 mm Dimensions Furnace 25 deep x 24 width x 51 height 980 deep x 620 width x 1290 h mm Dimensions overall installed 57 deep x 52 width x 51 height 1450 deep x 1300 width x 1320 h mm Weight overall...

Страница 21: ...6HR IDLE MODE RUN 18HR TOTAL DAILY CONSUMPTION 47 76 kg 40 80 kg 105 07 lbs 89 76 lbs 1 91 bushels 1 63 bushels ASSUMING LOW HIGH MODE RUN 9HR IDLE MODE RUN 15HR TOTAL DAILY CONSUMPTION 60 60 kg 52 80...

Страница 22: ...ximum premium grade 3 maximum standard grade Moisture Content 8 maximum It should be 100 natural wood Type of tree source will have effect on energy output Hardwood is better No methods of supporting...

Страница 23: ...a bag about 20 lbs of pellets at the bottom of the hopper first Total volumetric capacity of hopper is about 8 bushels The reason is furnace and fire pot are cold during the first fire It is always b...

Страница 24: ...the first fire 15 Now just sit back and enjoy the heat 16 If room thermostat is connected you don t have to choose any mode Room thermostat will take over the control of furnace 6 7 FIRST FIRE START...

Страница 25: ...event furnace overheat This mode eliminates re firing of the furnace when you come back to the house NOTE display will indicate the mode 2 Automatic It is automatically activated by the room thermosta...

Страница 26: ...PARTS CHIMNEY FIRES ARE NOT COV ERED BY THE LIFETIME LIMITED WARRANTY THE FIREBOX BECOMES VERY HOT DURING OPERATION LET THE FURNACE COOL COMPLETELY BEFORE CONDUCTING SERVICE WHENEVER ANY PORTION OF TH...

Страница 27: ...should be directed to the drain 7 5 CONTROL OF CONDENSATION There are wave tube baffles in the heat exchange tubes These are placed there to reduce the speed of ex haust gas and keep more heat in the...

Страница 28: ...own the furnace Wait until it cools Remove the fire pot and clean the air holes Problem Smoking Solution Check exhaust pipes and chimney for proper draft Check moisture of fuel During first fire it is...

Отзывы: