Napoleon GDS60-N Скачать руководство пользователя страница 6

6

W415-0788 / 05.15.09

4.1

THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER

 to 

conform with local codes. Installation practices vary from region to region and  it is important to know the 
specifi cs that apply to your area, for example in Massachusetts State:
• 

The appliance damper must be removed or welded in the open position prior to installation of a appliance 
insert or gas log.

• 

The appliance off valve must be a “T” handle gas cock.

• The 

fl exible connector must not be longer than 36 inches.

• 

A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.

• 

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent 
sealed combustion product.

 The installation must conform with local codes or, in 
absence of local codes, the National Gas and Propane 
Installation Code CSA B149.1 in Canada, or the 
National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the 
United States. Suitable for mobile home installation if 
installed in accordance with the current standard CAN/
CSA Z240MH Series, for gas equipped mobile homes, 
in Canada or ANSI Z223.1 and NFPA 54 in the United 
States.

As long as the required clearance to combustibles is maintained, the most desirable and benefi cial location 
for a Napoleon® appliance is in the center of a building, thereby allowing the most effi cient use of the heat 
created. The location of windows, doors and the traffi c fl ow in the room where the appliance is to be located 
should be considered. If possible, you should choose a location where the vent will pass through the house 
without cutting a fl oor or roof joist.

When the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood 
fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.

We suggest that our gas 
hearth products be installed 
and serviced by professionals 
who are certified in the U.S. 
by the National Appliance 
Institute

® (NFI) as NFI Gas 

Specialists

www.nficertified.org

The appliance, when installed with a blower, must be electrically connected and grounded in accordance with 
local codes. In the absence of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or 
the ANSI/NFPA 70-1996 National Electrical Code in the United States. The blower power cord must be con-
nected into a properly grounded receptacle. The grounding prong must not be removed from the cord plug.

1.4 GENERAL 

INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION 

AND QUALITY! 

Minimum inlet:

 Gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column 

for propane. 

Maximum inlet:

 Gas pressure is 7 inches water column for natural gas and 13 inches water column for pro-

pane. 

When the valve is set to "HI", the manifold pressure under fl ow conditions is 3.5 inches water column for natu-
ral gas and 10 inches water column for propane. When the appliance is installed at elevations above 4,500ft, 
and in the absence of specifi c recommendations from the local authority having jurisdiction, the certifi ed high 
altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft. 

Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in propane. Expansion / 
contraction noises during heating up and cooling down cycles are normal and to be expected.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convert-
ible for use with other gases, unless a certifi ed kit is used.

INSTALLER:

 It is your responsibility to check off the appropriate box on the rating plate according to the 

model, venting and gas type of the unit.

NorthlineExpress.com

http://www.northlineexpress.com

Toll-Free 1-866-667-8454

Содержание GDS60-N

Страница 1: ...liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediate...

Страница 2: ...2 3 HORIZONTAL AIR TERMINAL INSTALLATION MODEL GDS60 26 4 2 4 VERTICAL AIR TERMINAL INSTALLATION MODEL GDS60 27 4 3 APPLIANCE VENT CONNECTION MODEL GDS60 28 4 4 MOBILE HOME INSTALLATION MODEL GDS60 28...

Страница 3: ...its venting system should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc...

Страница 4: ...N gas heater and any other warranties expressed or implied with respect to this product its components or accessories are excluded NAPOLEON neither assumes nor authorizes any third party to assume on...

Страница 5: ...CTS PLACED IN FRONT OF THE FIREPLACE MUST BE KEPT A MINIMUM 48 FROM THE FRONT FACE OF THE UNIT THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH...

Страница 6: ...nel extending the full width and depth We suggest that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National Appliance Institute NFI as NFI Ga...

Страница 7: ...ency of 78 Maximum output for propane is 24 570 BTU hr at an efficiency of 78 Maximum A F U E Annual Fuel Utilization Efficiency rating is 72 for natural gas and 71 for propane REAR VENT HORIZONTAL TE...

Страница 8: ...ze after ignition Vent lengths that pass through unheated spaces attics garages crawl spaces should be insulated with the insulation wrapped in a protective sleeve to minimize condensation Provide a m...

Страница 9: ...cluded or 1 12 to 7 12 pitch roof terminal kit GD110 8 12 to 12 12 roof terminal kit GD111 flat roof terminal kit GD112 or periscope kit GD180 for wall penetration below grade in conjunction with the...

Страница 10: ...5 09 2 2 TYPICAL VENT INSTALLATIONS 30 1 2 TOP VENT REAR VENT 16 MINIMUM 40 FEET MAXIMUM 34 MINIMUM 16 MINIMUM 40 FEET MAXIMUM 34 MINIMUM 24 NorthlineExpress com http www northlineexpress com Toll Fre...

Страница 11: ...ADE 24 MINIMUM REGARDLESS OF HORIZONTAL VENT LENGTH MAX HORIZONTAL RUN 34 MAXIMUM 29 MINIMUM 30 1 2 59 1 2 MINIMUM PLUS RISE 24 MAX 24 MINIMUM PLUS RISE See VENTING section NorthlineExpress com http w...

Страница 12: ...is located a minimum 12 above grade The maximum allowable vent length is 10 9 4 24 MAXIMUM 0 RISE CORNER INSTALLATION 2 4 CORNER INSTALLATION REAR EXIT 2 3 SPECIAL VENT INSTALLATIONS 29 MINIMUM 12 MI...

Страница 13: ...Clearance to a mechanical air supply inlet L 7 7 Clearance above a paved sidewalk or paved driveway located on public property M 12 12 Clearance under a veranda porch deck or balcony N 16 16 Clearanc...

Страница 14: ...the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 13 2 REAR EXIT Horizontal Termination Vertical Termination Vertical rise is equal to or greater than the horiz...

Страница 15: ...l of both horizontal vent lengths Hr and offsets Ho in feet HR combined horizontal vent lengths in feet HO offset factor 03 total degrees of offset 90 in feet VT combined vertical vent lengths in feet...

Страница 16: ...la 1 HT 4 2 VT 4 2 VT 4 2 x 6 25 2 FT Formula 2 HT VT 24 75 FT 16 7 24 75 Since both formulas are met this vent configuration is acceptable 0 5 15 20 100 50 150 12 5 19 1 2 57 147 2 The shaded area wi...

Страница 17: ...re than one 90 elbow the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet Example 1 V1 3 FT V2 8 FT VT V1 V2 3 8 11 FT H1 2 5 FT H2 2 FT HR H1 H2 2 5 2 4 5 FT HO 03 three 90 elbows 90...

Страница 18: ...mula 1 HT VT 14 6 15 Formula 2 HT VT 40 FT 29 6 40 Since both formulas are met this vent configuration is acceptable 0 2 5 5 7 5 10 12 5 15 40 10 20 30 17 5 20 1 6 1 6 38 3 90 V1 V2 H1 H2 90 90 90 H3...

Страница 19: ...5 5 5 FT H1 2 FT H2 1 FT H3 1 FT H4 1 5 FT HR H1 H2 H3 H4 2 1 1 1 5 5 5 FT HO 03 four 90 elbows one 45 elbow 90 03 90 90 90 90 45 90 9 45 FT HT HR HO 5 5 9 45 14 95 FT HT VT 14 95 5 5 20 45 FT Formul...

Страница 20: ...apply Formula 1 HT VT Formula 2 HT VT 40 feet Example 6 V1 5 FT V2 6 FT V3 10 FT VT V1 V2 V3 5 6 10 21 FT H1 8 FT H2 2 5 FT HR H1 H2 8 2 5 10 5 FT HO 03 four 90 elbows 90 03 360 90 8 1 FT HT HR HO 10...

Страница 21: ...FT HR H1 H2 6 2 8 FT HO 03 four 90 elbows 90 03 360 90 8 1 FT HT HR HO 8 8 1 16 1 FT HT VT 16 1 4 5 20 6 FT Formula 1 HT 3 5 VT 3 5 VT 3 x 4 5 13 5 FT 16 1 13 5 Since this formula is not met this ven...

Страница 22: ...18 2_3 3 1 ORIFICE REPLACEMENT REAR VENT TERMINATION In rear exit installations with no vertical vent run the BTU input must be reduced to 21 000 BTU by changing the orifice In order to access the ori...

Страница 23: ...lustrated When reinstalling in the alternate position Check gaskets for tears replace if necessary to ensure a proper seal 4 Gasket 7 Cover Plate 7 Gasket 4 Gasket 4 Collar 7 Gasket 7 Collar Outer Top...

Страница 24: ...LOOSE MATERIALS OR INSULATION TO TOUCH THE VENT PIPE REMOVE INSULATION TO ALLOW FOR THE INSTALLATION OF THE ATTIC SHIELD AND TO MAINTAIN CLEARANCES TO COMBUSTIBLES 4 1 MINIMUM CLEARANCE TO COMBUSTIBL...

Страница 25: ...hat are less than 8 1 2 thick but the vent shield must extend the full depth of the combustible wall A Apply a bead of caulking not supplied around the corner edge of the inside surface of the firesto...

Страница 26: ...vailable from your authorized dealer distributor See accessories to order specific kits required A Determine the air terminal location cut and frame a square opening as illustrated in the ceiling and...

Страница 27: ...terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector is properly centred within the fl...

Страница 28: ...done by a qualified installer Do not use open flame Move the appliance into position and secure If equipped with a flex connector the appliance is designed to accept a 1 2 gas supply Without the conn...

Страница 29: ...SE D AIR CERTIFIED UNDER CSA 2 33 2000 ANSI Z21 88 2000 VENTED GAS FIREPLACE HEATER AS A DIRECT VENT AND CSA2 22 M98 ANSI Z21 50 1998 VENTED GAS FIREPLACE AS A B VENT HOMOLOGUE SELON LES NORMES CSA 2...

Страница 30: ...into the appliance flue collar F Connect the upper wire terminals to the spill switch G Disconnect the wire lead from terminal 3 on the valve and re connect to the male end of the spill switch wire C...

Страница 31: ...the flashing over the vent pipe and slide it underneath the sides and upper edge of the shingles Ensure that the vent pipe is properly centered within the flashing giving a 3 4 margin all around Faste...

Страница 32: ...ove the backing of the logo supplied and centre over the logo installation holes as indicated 5 2 SWITCH AND BRACKET INSTALLATION 1 3 CONNECT THE TWO WIRES TO THE SWITCH TERMINALS 2 NorthlineExpress c...

Страница 33: ...ts retainers located at either side on the top 5 4 3 Open the valve control cover Pull the latch handles forward to release The door may now be safely removed by swinging the bottom out and lifting it...

Страница 34: ...end of the grate as shown to prevent it from rocking 6 7 Position the notch located in log 6 against the grate post Place the bottom of log 7 against the right outermost grate post and the top into t...

Страница 35: ...turn the unit off and check for vent blockage or restriction If necessary consult with a qualified inspector 6 1 OPERATING INSTRUCTIONS The on off switch is located on the back of the unit at the top...

Страница 36: ...UIPPED WITH AN IGNITION DEVICE WHICH AUTOMATI CALLY LIGHTS THE PILOT DO NOT TRY TO LIGHT BY HAND B BEFORE OPERATING SMELL ALL AROUND THE FIREPLACE AREA FOR GAS AND NEXT TO THE FLOOR BECAUSE SOME GAS I...

Страница 37: ...CPI IPI MODE DC BACK UP SUPPLY NOT USED STABALIZED SUPPLY OUTLET GROUND DFC VALVE ORANGE GREEN GROUND EYELET ON OFF IPI CPI DISCONNECT AND INSTALL LEADS TO MILLIVOLT THERMOSTAT NorthlineExpress com h...

Страница 38: ...proximately 30 45 minutes after the appliance has been turned off Use of the fan increases the output of heat Drywall dust will penetrate into blower bear ings causing irreparable damage and must be p...

Страница 39: ...o disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing This appliance and its venting system should be inspected befor...

Страница 40: ...nal injury WARNING COMMON COMPONENTS REF NO PART NO DESCRIPTION 1 W135 0209 LOG 1 2 W135 0082 CHARCOAL PIECE LOG 2 3 W135 0076 LOG 3 4 W135 0210 LOG 4 5 W135 0211 LOG 5 6 W135 0212 LOG 6 7 W135 0213 L...

Страница 41: ...CK BAND 45 GD180 PERISCOPE TERMINAL KIT 35 BM6790 90 ELBOW 7 DIAMETER 37 BM67ADJ 30 TO 53 ADJUSTABLE PIPE 7 DIA 38 W010 1313 FIRESTOP SPACER 39 W585 0267 TOP VENT SHIELD 40 W020 0032 HARDWARE 41 BM373...

Страница 42: ...301 HEAT GUARD 62 W175 0001 4 COUPLER 46 GD 201 PERISCOPE 63 GDSRP KT RESTRICTOR KIT 64 GS 150KT ADAPTOR KIT 65 W025 0003 DECORATIVE BLACK BAND ROOF TERMINAL KITS REF NO PART NO DESCRIPTION GD110 1 1...

Страница 43: ...0788 05 15 09 47 50 49 48 61 46 24 37 42 38 44 35 25 27 10 1 2 3 4 5 7 6 29 33 32 44 28 26 55 9 20 11 57 61 36 8 41 44 44 51 13 12 NorthlineExpress com http www northlineexpress com Toll Free 1 866 6...

Страница 44: ...assemblies are properly grounded to the metal chassis of the fireplace or log set Faulty module Turn the ON OFF switch to the OFF position Remove the igniter wire I from the module Place the ON OFF s...

Страница 45: ...all wiring is installed exactly as specified Wiring harness Inspect the wiring harness and verify the harness is tightly connected to the module Verify that you have 7 wires and they are connected in...

Страница 46: ...Y Appliance Service History This heater must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name 43 1 NorthlineExpress com http www nort...

Страница 47: ...47 W415 0788 05 15 09 14 0 NOTES 44 1 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 48: ...48 W415 0788 05 15 09 44 1 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Отзывы: