8
W415-0682 / D / 02.06.12
1.4.7 ELECTRICAL BOX INSTALLATION
NOTE: Before fi nishing in the appliance, the power vent must be installed.
A.
Start by removing the pre-
fi
nishing access panel or opening lower louvre.
B.
Position the Power Vent Control Module in a convenient location (not on top of the heat shield in the
LHD50) and Velcro it to the base of the appliance.
C.
Slide the 20’ power vent cable through the right side of the appliance and connect the box connector to
the side panel, see “INSTALLATION OVERVIEW” section for illustration.
D.
Feed the wires through the inside panel, slide the split bushing over the coated wires and snap into
the 7/8” hole to protect the wires as illustrated. Attach the connections as per the appropriate wiring
diagram. See “WIRING DIAGRAM AND INSTALLATION” section.
E.
Plug the power vent control module into either the appliance junction box or the control module, if
equipped.
POWER VENT
CONTROL
MODULE
BX SNAP
BUSHING
20’ POWER
VENT CABLE
SPLIT BUSHING
REQUIRED
CONTROL MODULE
JUNCTION BOX
LHD50 ILLUSTRATED