6

W415-0682 / D / 02.06.12

1.4.2 POWER VENT INSTALLATION

23.6

A.

 

Stretch the inner 

fl

 ex pipe to the required length taking 

into account the additional length needed for the 

fi

 n-

ished wall surface. Slip the vent pipe a minimum of 3” 
over the inner sleeve of the terminal and secure with 3 
#8 screws. Apply a heavy bead of the high temperature 
sealant W573-0007 Mill Pac (not supplied).

B.

 

Using the outer 

fl

 ex pipe, slide over the outer combus-

tion air sleeve of the terminal and secure with 3 #8 
screws. Seal using high temperature sealant W573-
0002 (not supplied).

C. 

Apply a bead of caulking (not supplied) to the framed 
opening and secure the terminal. Ensure the arrows 
stamped into the frame assembly are pointing upwards. 

NOTE: For fi restop spacer installation instructions, 
see PVA kit or the appliance Installation Manual.

D. 

Route venting through framed opening and 

fi

 restop spacer to the 

appliance.

E.

 

The terminal mounting plate may be recessed into the exterior 
wall or siding no greater than the depth of its return 

fl

 ange.

F.

 

If more vent pipe needs to be used to reach the appliance, couple 
them together as illustrated. The vent system must be supported 
approximately every 3 feet for both vertical and horizontal runs. 
Use noncombustible strapping to maintain the minimum clearance 
to combustibles.  

G.

 

Install the reducer (if required) or vent and properly secure and 
seal to the unit using high temperature sealant 
W573-0007 Mill Pac (not supplied).

HI-TEMP

SEALANT

#8 X 1/2” SELF DRILLING 

SCREWS & WASHERS

INNER COUPLER

OUTER COUPLER

OUTER 

FLEX PIPE

INNER 
FLEX PIPE

OUTER 

FLEX PIPE

TERMINAL

CAULKING

FIRESTOP
SPACER

#10 X 2”

SCREWS

HIGH 

TEMPERATURE 

SEALANT

RETURN 

FLANGE

1.4.3 INITIAL FIRING PROCEDURES

!

WARNING

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT 

WITH THE GLASS DOOR OPENED OR REMOVED. PURGE SHOULD BE PERFORMED BY A QUALI-

FIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT THE BURNER BE-

FORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION.

In some instances the system may not light pilot/burner with the door open/removed. Partially blocking the 
exhaust 

fl

 ue collar will allow the safety pressure switch to activate and allow gas 

fl

 ow to the pilot during the 

initial test 

fi

 ring.

Содержание GAS POWER VENT

Страница 1: ...LIANCE When selecting a gas appliance for use with the GPV take into consideration the various requirements and limitations in the venting installation section for the following models Models Equipped...

Страница 2: ...TE WITH GPV POWER VENT TERMINAL 12 1 6 4 DEXEN IPI 6003 3V COMPLETE WITH GPV POWER VENT TERMINAL 13 1 6 5 SIT REMOTE CONTROLLED MILLIVOLT SYSTEM COMPLETE WITH GPV POWER VENT TERMINAL 14 2 0 ADJUSTMENT...

Страница 3: ...A typical vent configuration Reducer refer to power vent adapter kit PVA for specific vent ing instructions where applicable Gas Power Vent Terminal Electrical Box velcro to base LHD50 Illustrated Fir...

Страница 4: ...rance under a veranda porch or deck N 12 12 Clearance above the roof O 2 2 Clearance from an adjacent wall including neighbouring buildings P 8 8 Roof must be non combustible without openings Q 3 3 Se...

Страница 5: ...onnections must conform with local codes or in the absence of local codes use the current CSA C22 1 Canadian Electrical Code in Canada or the ANSI NFPA 70 National Electrical Code in the United States...

Страница 6: ...ge F If more vent pipe needs to be used to reach the appliance couple them together as illustrated The vent system must be supported approximately every 3 feet for both vertical and horizontal runs Us...

Страница 7: ...0 IN THE UNITED STATES ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT WITH THE GLASS DOOR OPENED OR REMOVED 69 2 It is necessary to hard wire this appliance Permane...

Страница 8: ...f the appliance and connect the box connector to the side panel see INSTALLATION OVERVIEW section for illustration D Feed the wires through the inside panel slide the split bushing over the coated wir...

Страница 9: ...al codes use the current CSA C22 1 Canadian Electrical Code in Canada or the ANSI NFPA 70 National Electrical Code in the United States REFER TO PVA KIT FOR APPLIANCE SPECIFIC INSTRUCTIONS 1 6 1 SIT I...

Страница 10: ...OW MOTOR BLACK MOTOR BROWN MOTOR WHITE Receiver Control Module POWER Pilot Assembly GREEN ON OFF BLACK RED IMPORTANT IF USED IT MUST BE CONNECTED TO A 6 VOLT BATTERY PACK HOWEVER MUST NOT BE USED WHEN...

Страница 11: ...Terminal Power Vent Control Module Appliance Junction Box JUMPER 2 1 NOTE Must use double pole switch supplied or double pole thermostat not supplied with specific power vent adaptor kit NOTE Downward...

Страница 12: ...pliance Junction Box BLACK WHITE YELLOW YELLOW BLOWER VAC SWITCH GREEN GPV Terminal Double Pole Switch YELLOW YELLOW JUMPER 2 1 IMPORTANT A receptacle may need to be installed as a power source for th...

Страница 13: ...m the Power vent control module Dexen Gas Valve Ignition Module Battery Holder Battery Relay ORANGE YELLOW GREEN BLACK ORANGE BLUE RED BROWN BROWN BLUE BLACK YELLOW YELLOW BLACK WHITE ORANGE RED GREEN...

Страница 14: ...itch supplied or double pole thermostat not supplied with specific power vent adaptor kits NOTE Downward venting is not allowed with appliances that use standing pilots 1 Disconnect one of the two wir...

Страница 15: ...art Finish IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FOR FURTHER INFORMATION CONTACT YOUR AUTHORIZED DEALER 41 1 FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PA...

Страница 16: ...chamber surfaces Clean the glass with a gas appliance glass cleaner DO NOT CLEAN GLASS WHEN HOT If deposits are not cleaned off regularly the glass may become permanently marked Exhaust fumes smelled...

Отзывы: