14
W415-0682 / D / 02.06.12
PILOT
BURNER
THERMOCOUPLE
THERMOPILE
RED
WHITE
BLACK
WHITE
ORANGE
RED
YELLOW
YELLOW
GREEN
Pilot Assembly
SIT Millivolt Gas Valve
Double Pole
Switch
BLACK
WHITE
YELLOW
YELLOW
BLOWER
VAC SWITCH
GREEN
GPV Terminal
Power Vent
Control
Module
Appliance
Junction Box
JUMPER
2
1
Receiver
NOTE: Must use double pole switch (supplied) or double pole thermostat (not supplied) with specifi c
power vent adaptor kits.
NOTE: Downward venting is not allowed with appliances that use standing pilots.
1.
Disconnect one of the two wires from the receiver to the valve. Connect it to one of the yellow
wires from the power vent control module.
2.
Connect a jumper wire to the valve where the receiver wire was disconnected and to the other yellow
wire from the power vent control module.
1.6.5 SIT REMOTE CONTROLLED MILLIVOLT SYSTEM COMPLETE WITH GPV
POWER VENT TERMINAL