![Napoleon GAS POWER VENT Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/napoleon/gas-power-vent/gas-power-vent_installation-instructions-manual_3313842011.webp)
11
W415-0682 / D / 02.06.12
1.6.2 SIT MILLIVOLT 820 NOVA COMPLETE WITH GPV POWER VENT TERMINAL
PILOT
BURNER
THERMOCOUPLE
THERMOPILE
RED
WHITE
BLACK
WHITE
ORANGE
RED
YELLOW
YELLOW
GREEN
Pilot Assembly
SIT Millivolt Gas Valve
Double Pole
Switch
BLACK
WHITE
YELLOW
YELLOW
BLOWER
VAC SWITCH
GREEN
GPV Terminal
Power Vent
Control
Module
Appliance
Junction Box
JUMPER
2
1
NOTE: Must use double pole switch (supplied) or double pole thermostat (not supplied) with specifi c
power vent adaptor kit.
NOTE: Downward venting is not allowed with appliances that use a standing pilot.
1.
Connect the jumper wires to tabs TP/TH and TH on the gas valve.
2.
Connect the jumper wire to the two Yellow wires from the Power vent control module.
IMPORTANT:
A RECEPTACLE MAY NEED TO BE INSTALLED AS A POWER SOURCE FOR THE GPV.