The thermostat and control wiring should be a minimum of 18 AWG copper. Excessive lengths of wire may
result in enough voltage drop to impair the proper functioning of the furnace. For thermostat wires in excess of
25 feet (7.6m), use 16 AWG; 50 feet (15.2m), use 14 AWG.
5.2.5 Low Voltage Wiring
ANY REPLACED COMPONENT MUST BE INSTALLED IN SAME MANNER AS THE ORIGINAL
COMPONENT IN ORDER TO MAKE SURE THE PROPER OPERATION OF THE UNIT IS
RESTORED.
WARNING
!
!
Auto Reset temperature limit control is provided for each heating element which will shut off the power to the
heating element if the unit is overheated for any reason.
Once unit cools down, the power to the heating elements will be restored and unit will resume the operation.
For additional safety, each element is also provided with non-resettable temperature limiting control which
will permanently cut the power to the heating element(s) if the unit is abnormally overheating. If this occurs,
the unit will no longer provide heating, at which point a certified service technician or service agency must be
contacted to troubleshoot the system and replace any damaged components.
5.2.6 Thermostat
5.2.8 Limit Control
The unit contains a direct-drive, multi-speed blower. The proper speeds have been preset at the factory for
heating and cooling. For recommended heating/cooling speeds for specific models refer to tables shown in
“6.3 Air Flow”
section. Direct-drive blower motors are permanently lubricated and do not require oiling.
H53.2
The thermostat should be located approximately 5 feet (1524mm) above the fl oor, on an inside wall where there
is good natural air circulation, and where the thermostat will be exposed to average room temperatures. Avoid
locations where the thermostat will be exposed to cold drafts, heat from nearby lamps or appliances, exposure to
sunlight, heat from inside wall stacks, etc.
5.2.7 Blower
Содержание Condo Pack
Страница 58: ...58 IOM IOM W415 2288 08 29 2019 9 3 P E HEATING MODULE...
Страница 62: ...62 IOM IOM W415 2288 08 29 2019 44 1...
Страница 63: ...63 IOM W415 2288 08 29 2019 44 1...
Страница 122: ...58 IOM IOM W415 2288 08 29 19 9 3 MODULE DE CHAUFFAGE LECTRIQUE CONDO PACK P E...
Страница 126: ...62 IOM IOM W415 2288 08 29 19 44 1...
Страница 127: ...IOM W415 2288 08 29 19 44 1...