![Napoleon Condo Pack Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/napoleon/condo-pack/condo-pack_installation-and-operating-instructions-manual_3307042036.webp)
36
IOM
IOM
W415-2288 / 08.29.2019
Distribution Block
Fuse Block
Ground Block
15
Transformer
Side
Screw
1
3
2
4
5
6
7
8 9
9
Transformer
1
3
2
4
5
6
7
8
9
Ground Block
Distribution Block
Fuse Block
1 2
3
A1
B1
B2
A2
Transformer
Contactor
Capacitor
X3 Molex
AC Molex
Fuse Block
Ground
Block
Distribution
Block
Remove all 9 screws
holding the heating
module in, as shown in
the this diagram (28).
Do not forget to
remove the side screw #9.
Turn the Main Power Disconnect ON.
Secure furnace module by replacing
the 9 screws on the front.
Make sure not to forget side screw #9.
Reconnect wiring harnesses
A, B, power wires,
thermostat and ground wires.
1 2
3
Once everything is disconnected, slide
the heating module out.
When sliding
heating module
back into the
cabinet, make
sure the module
slides UNDER
the rail.