background image

17

W415-0381 / H / 12.07.07

1. 

Move the fi replace into position.

2. 

Fasten the roof support to the roof using the screws provided. 

FIGURE 21.

 The roof support is optional. In this case the venting is 

to be adequately supported using either an alternate method suitable 
to the authority having jurisdiction or the optional roof support. 

3.

 Apply high temperature sealant W573-0007 (not supplied) 

to the outer edge of the inner sleeve of the air terminal. Slip a 5" 
diameter coupler a minimum of 2" over the sleeve and secure using 
3 screws. 

4

.

 Apply high temperature sealant 

W573-0007 (not supplied) to the outer 
edge of the of the outside sleeve of the 
air terminal. Slip a 8" diameter coupler 
over the sleeve and secure as before. 

FIGURE 25

. Trim the 8" coupler even 

with the 5" coupler end.

5

.

 Thread the air terminal pipe as-

sembly down through the roof  support 
and attach, ensuring that a minimum 
16" of air terminal will penetrate the 
roof when fastened. 

FIGURE 23.

 

If 

the attic space is tight, we recom-
mend threading the Wolf Steel vent 
pipe collar or equivalent loosely 
onto the air terminal assembly 
as it is passed through the attic. 
FIGURE 29. 

The air terminal must be 

located vertically and plumb. 

6.

 Remove nails from the shingles, 

above and to the sides of the chim-
ney. Place the fl ashing over the air 
terminal and slide it underneath the 
sides and upper edge of the shingles. Ensure that the air terminal 
is properly centered within the fl ashing, giving a 3/4" margin all 
around. Fasten to the roof. Do NOT nail through the lower portion 
of the fl ashing. Make weather-tight by sealing with caulking. Where 
possible, cover the sides and top edges of the fl ashing with roofi ng 
material. 

FIGURE 23.

7.

 

Aligning the seams of the terminal and air terminal connector, 

place the terminal over the air terminal connector making sure the 
inner sleeve goes into the hole in the terminal. Secure with the 3 
screws provided.

8.

  Apply a heavy bead of weatherproof caulking 2" above the 

fl ashing. Note: Maintain a minimum of 2" space between the air 
inlet base and the storm collar. Install the storm collar around the 
air terminal and slide down to the caulking. Tighten to ensure that 
a weather-tight seal between the air terminal and the collar is 
achieved.

9.

  Continue adding rigid venting sections, sealing and securing 

as above. Attach a 5" collapsed telescopic pipe to the last section 
of rigid piping. Secure with screws and seal. Repeat using a 8" 
telescopic pipe.

10. 

Run a bead of high temperature sealant W573-0007 (not sup-

plied) Mill Pac around the outside of the 5" collar on the fi replace. 
Pull the adjustable pipe a minimum of 2" onto the collar. Secure with 
3 screws. Repeat with the 8" telescopic pipe.

11. 

In the attic, slide the vent pipe collar down to cover up the open 

end of the shield and tighten. This will prevent any materials, such as 
insulation, from fi lling up the 1" air space around the pipe. 

FIGURE 30

FIGURE 29

FIGURE 32

VERTICAL VENTING INSTALLATION

GAS INSTALLATION

RESTRICTING VERTICAL VENTS

RESTRICTOR PLATE

TOP OF THE 

FIREBOX

FIGURE 31

For ease of accessibility, an optional remote wall switch may be 
installed in a convenient  location. 

A 20’ length of millivolt wire is 

connected to the gas valve for the wall switch. However if a greater 
length is required

 route 2-strand (solid core) millivolt wire through the 

electrical hole located at the bottom left side of the unit. The recom-
mended maximum lead length depends on wire size: 

 

WIRE SIZE 

MAX. LENGTH

 

14 gauge 

  100 feet

 

16 gauge 

    60 feet

 

18 gauge 

    40 feet

Attach the two leads to terminals 1 and 3 located on the gas valve.

OPTIONAL WALL SWITCH 

INSTALLATION

Vertical terminations may display a very active fl ame. As this appear-
ance is not desirable, the vent exit must be restricted using restrictor 
plate, W500-0205.  This reduces the velocity of the exhaust gases, 
slowing down the fl ame pattern and creating a more traditional ap-
pearance.

Remove the two screws on either side of the exhaust collar inside the 
fi rebox. Install the plate as shown. Replace the screws.

Proceed once the vent installation is complete.

NOTE:  All gas connections must be contained within the fi re-
place when complete.

1.

 Move the fi replace into position and secure to the fl oor through 

the 1/4" holes located at either side of the base.

2. 

The fi replace is designed to accept 3/8" gas supply line.  The 

fi replace is equipped with a 3/8" manual shut-off valve.

3. 

 Connect the gas supply in accordance to local codes.  In the 

absence thereof, install according to the National Installation Code.

4. 

 When fl exing any gas line, support the gas valve so that the 

lines are not bent or kinked.

5. 

Check for gas leaks by brushing on a soap and water solu-

tion. 

DO NOT USE OPEN FLAME.

Purge all gas lines with the glass door of the stove removed. 
Assure that a continuous gas fl ow is at the burner before re-
installing the door.

Содержание BGD42

Страница 1: ...1 W415 0381 H 12 07 07 W415 0381 H 12 07 07 10 00...

Страница 2: ...nts toddlers from touching hot surfaces Even after the fireplace is out the glass and or screen will remain hot for an extended period of time Check with your local hearth specialty dealer for safety...

Страница 3: ...venting components used in the installation of the replace NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life subject to the following conditions During...

Страница 4: ...rity having jurisdiction the certi ed high altitude input rating shall be reduced at the rate of 4 for each additional 1 000ft Maximum output for natural gas is 19 500 BTU hr at an ef ciency of 68 5 w...

Страница 5: ...5 W415 0381 H 12 07 07 FIGURE 1 INSTALLATION OVERVIEW FIGURE 2...

Страница 6: ...Direct Temp and American Metal Amerivent follow the installation procedure provided with the venting components All outer pipe joints of these venting systems must be sealed using Red RTV Hight Temper...

Страница 7: ...AIR TERMINAL LOCATION CLEARANCES 32 32 32 32 32 32 4 Using a soffit heat shield W585 0096 or equivalent the distance may be reduced to a minimum of 18 It is recommended to maximize the distance to th...

Страница 8: ...at when nal grading is completed the bottom air slot is located a minimum of 12 above grade FIGURES 4 a b FIGURE 5 TYPICAL VENT INSTALLATIONS NOTE When terminating vertically the restrictor plate W500...

Страница 9: ...tal run horizontal run verti cal rise to maximum of 40 feet vertical rise is less than horizontal run horizontal run verti cal rise to maximum of 24 75 feet 4 2timesthe vertical rise equal to or great...

Страница 10: ...of offset 135 in feet VT combined vertical vent lengths in feet feet inches 1 0 03 0 5 15 0 45 6 0 30 0 9 11 0 45 1 35 16 0 90 2 7 32 0 the rst 45 and 90 offset has a zero value and is shown in the f...

Страница 11: ...T when HT VT Simple venting con guration only one 45 and 90 elbow Example 2 V1 4 ft V2 1 5 ft VT V1 V2 4 ft 1 5 ft 5 5 ft H1 2 ft H2 1 ft H3 1 ft H4 1 5 ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 one 45...

Страница 12: ...et 25 9 40 Since both formulas are met this vent con guration is acceptable when HT VT Simple venting con gurations FIGURE 10 REQUIRED VERTICAL RISE IN FEET VT HORIZONTAL VENT RUN PLUS OFFSETS IN FEET...

Страница 13: ...40 Since both formulas are met this vent con guration is acceptable REQUIRED VERTICAL R I S E I N FEET VT HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT FIGURE 12 The shaded area within the lines represe...

Страница 14: ...learance of 2 all around the vent pipe on all horizontal runs to combustibles is required Use restop spacer W010 1778 supplied VERTICAL VENT SECTIONS A minimum of 1 all around the vent pipe on all ver...

Страница 15: ...combus tion air collar and secure with 3 8 screws 6 If more liner needs to be used to reach the replace couple them together as illustrated The vent system must be supported approximately every 3 feet...

Страница 16: ...erminal sleeves engage into the vent pipes and sealant Secure the terminal to the exterior wall and make weather tight by sealing with caulking not supplied Theairterminalmountingplatemaybe recessed i...

Страница 17: ...h a 5 collapsed telescopic pipe to the last section of rigid piping Secure with screws and seal Repeat using a 8 telescopic pipe 10 Run a bead of high temperature sealant W573 0007 not sup plied Mill...

Страница 18: ...is positioned and the vent system is installed Use 2x4 s and frame to local building codes FIGURES 33 It is not necessary to install a hearth extension with this replace system When roughing in the r...

Страница 19: ...Centre the nailing tab vertically on the corner post Figure 36 a Drill through the centre of the top and bottom slots in the nailing tab Secure using the two sheet metal screws supplied This allows t...

Страница 20: ...clips into the slots located at the bottom left and right corners of the unit To remove the louvres pull the back tabs of the clips forward while push ing the louvre assembly back Lift the clip B HING...

Страница 21: ...g embers for a maximum glowing effect Log colours may vary During the initial use of the replace the colours will become more uniform as colour pigments burn in during the heat activated curing proces...

Страница 22: ...ll automatically start approxi mately 10 minutes after lighting the fireplace and will run for ap proximately 30 45 minutes after the fireplace has been turned off Use of the fan increases the output...

Страница 23: ...valve has an interlock device which will not al low the pilot burner to be lit until the thermocouple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighti...

Страница 24: ...e gasket Adjust the pilot screw to provide properly sized ame Turn in a clockwise direction to reduce the gas ow Air shutters have been factory set open according to the chart below These settings are...

Страница 25: ...LANT 39 W175 0166 5 COUPLER 39 W175 0002 8 COUPLER 40 L42K LOUVRE KIT UPPER LOWER BLACK 40 L42PB LOUVRE KIT UPPER LOWER POLISHED BRASS 40 L42SS LOUVRE KIT UPPER LOWER BRUSHED STAINLESS STEEL 41 GDOI42...

Страница 26: ...26 W415 0381 H 12 07 07...

Страница 27: ...le and valve connection replace thermocouple replace valve Faulty valve replace Pilot burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defec tive co...

Страница 28: ...door gasketing is not broken or missing and that the seal is tight check that both 5 and 8 vent liners are free of holes and well sealed at all joints check that minimum rise per foot has been adhered...

Отзывы: