background image

16

W415-0381 / H / 12.07.07

FIGURE 25

5. Remove nails from the shingles, above and to the sides of 

the chimney. Place the fl ashing over the air terminal connector 
leaving a min. 3/4” of the air terminal connector showing above 
the top of the fl ashing.  Slide the fl ashing underneath the sides 
and upper edge of the shingles. Ensure that the air terminal con-
nector is properly centred within the fl ashing, 
giving a 3/4” margin all around. Fasten to the 
roof. Do not nail through the lower portion of 
the fl ashing. Make weather-tight by sealing with 
caulking. Where possible, cover the sides and 
top edges of the fl ashing with roofi ng material.  

6.  Aligning the seams of the terminal 

and air terminal connector, place the 
terminal over the air terminal connector 
making sure the liner goes into the hole in 
the terminal.  Secure with the three screws 
provided. 

7. Apply a heavy bead of weatherproof 

caulking 2" above the fl ashing.  Note:  Maintain a minimum 2” 
space between the air inlet base and the storm collar.  Install the 
storm collar around the air terminal and slide down to the caulk-
ing. Tighten to ensure that a weather-tight seal between the air 
terminal and the collar is achieved. 

8. 

If more liner needs to be used to reach the fi replace, couple 

them together as illustrated in

 Figure 22

. The vent system must be 

supported approximately every 3 feet for both vertical and horizon-
tal runs. Use noncombustible strapping to maintain a clearance to 
combustibles 

of 1". 

FIGURE 27

FIGURE 29

FIGURE 26

 

1. 

Install the 5" diameter fl exible 

vent pipe

 liner to the fi re-

place. Secure with 3 screws and fl at washers. Seal the joint 
and screw holes using the high temperature sealant  W573-
0007 (not supplied) Mill Pac.

2. 

Install the 8" diameter fl exible 

vent pipe

 to the fi replace. 

Attach and seal the joints with high temperature sealant 
W573-0002 (not supplied).

FIREPLACE VENT CONNECTION

USING RIGID VENT COMPONENTS

HORIZONTAL AIR TERMINAL INSTALLATION

EXTENDED HORIZONTAL AIR TERMINAL 

INSTALLATION

FIGURE 28

4. 

Holding the air terminal (with the 

air deflectors to the top), insert into 
both vent pipes with a twisting motion 
to ensure that both the terminal sleeves 
engage into the vent pipes and sealant. 
Secure the terminal to the exterior wall 
and make weather tight by sealing with 
caulking (not supplied). 

 

The air terminal mounting plate may be 
recessed into the exterior wall or siding by 1½", the 
depth of the return flange.

1. 

Follow the instructions for 

"Horizontal Air Terminal Instal-
lations", items 1 to 3. 

2. 

Continue adding com-

ponents alternating inner and 
outer venting. Ensure that all 
5" venting and elbows have 
suffi cient vent spacers attached 
and each  component is securely fastened to the 
one prior. Attach the 5" telescopic sleeve to the 
vent run. 

Repeat using a 8" telescopic sleeve. Secure 

and seal as before. To facilitate completion, attach 
5" and 8" couplers to the air terminal. 

3.

 Install the air terminal. 

See item 3 of the 

Horizontal Air Terminal Installation.

 Extend the 5" telescopic sleeve; 

connect to the air terminal assembly. Fasten with self tapping screws 
and seal. Repeat using the 8" telescopic sleeve.

The vent system must be supported approximately every 3 feet for 
both vertical and horizontal runs. Use Wolf Steel vent spacers every 
3 feet and either side of each elbow to maintain the minimum 1¼" 
clearance between the outer and inner vent pipes. Use Wolf Steel 
support ring assembly or equivalent noncombustible strapping to 
maintain the minimum clearance to combustibles for both vertical 
and horizontal runs. 

All inner exhaust and outer intake vent pipe joists may be sealed 
using either Red RTV high temp silicone sealant or Black high 
temp Mill Pac with the exception of  the fireplace exhaust flue 
collar which must be sealed using Mill Pac (not supplied).

 

1. 

Move the fi replace into position. Measure the vent length required 

between terminal and fi replace taking into account the 

additional length needed for the fi nished wall surface and any 1¼" overlaps 
between venting components.

2. 

Apply high temperature sealant 

W573-0007 (not supplied) Mill Pac to 
the outer edge of the 5" inner collar of 
the fi replace.  Attach the fi rst vent com-
ponent and secure using 3 self tapping 
screws. Repeat using 8" piping.  

3.

 The vent heat shield must be installed only when terminating 

horizontally. Remove the two screws nearest the vent collars on the 
top of the fi replace. Align the vent shield (supplied) and secure. 
Adjust the heat shield to touch the fi restop spacer.

Содержание BGD42

Страница 1: ...1 W415 0381 H 12 07 07 W415 0381 H 12 07 07 10 00...

Страница 2: ...nts toddlers from touching hot surfaces Even after the fireplace is out the glass and or screen will remain hot for an extended period of time Check with your local hearth specialty dealer for safety...

Страница 3: ...venting components used in the installation of the replace NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life subject to the following conditions During...

Страница 4: ...rity having jurisdiction the certi ed high altitude input rating shall be reduced at the rate of 4 for each additional 1 000ft Maximum output for natural gas is 19 500 BTU hr at an ef ciency of 68 5 w...

Страница 5: ...5 W415 0381 H 12 07 07 FIGURE 1 INSTALLATION OVERVIEW FIGURE 2...

Страница 6: ...Direct Temp and American Metal Amerivent follow the installation procedure provided with the venting components All outer pipe joints of these venting systems must be sealed using Red RTV Hight Temper...

Страница 7: ...AIR TERMINAL LOCATION CLEARANCES 32 32 32 32 32 32 4 Using a soffit heat shield W585 0096 or equivalent the distance may be reduced to a minimum of 18 It is recommended to maximize the distance to th...

Страница 8: ...at when nal grading is completed the bottom air slot is located a minimum of 12 above grade FIGURES 4 a b FIGURE 5 TYPICAL VENT INSTALLATIONS NOTE When terminating vertically the restrictor plate W500...

Страница 9: ...tal run horizontal run verti cal rise to maximum of 40 feet vertical rise is less than horizontal run horizontal run verti cal rise to maximum of 24 75 feet 4 2timesthe vertical rise equal to or great...

Страница 10: ...of offset 135 in feet VT combined vertical vent lengths in feet feet inches 1 0 03 0 5 15 0 45 6 0 30 0 9 11 0 45 1 35 16 0 90 2 7 32 0 the rst 45 and 90 offset has a zero value and is shown in the f...

Страница 11: ...T when HT VT Simple venting con guration only one 45 and 90 elbow Example 2 V1 4 ft V2 1 5 ft VT V1 V2 4 ft 1 5 ft 5 5 ft H1 2 ft H2 1 ft H3 1 ft H4 1 5 ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 one 45...

Страница 12: ...et 25 9 40 Since both formulas are met this vent con guration is acceptable when HT VT Simple venting con gurations FIGURE 10 REQUIRED VERTICAL RISE IN FEET VT HORIZONTAL VENT RUN PLUS OFFSETS IN FEET...

Страница 13: ...40 Since both formulas are met this vent con guration is acceptable REQUIRED VERTICAL R I S E I N FEET VT HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT FIGURE 12 The shaded area within the lines represe...

Страница 14: ...learance of 2 all around the vent pipe on all horizontal runs to combustibles is required Use restop spacer W010 1778 supplied VERTICAL VENT SECTIONS A minimum of 1 all around the vent pipe on all ver...

Страница 15: ...combus tion air collar and secure with 3 8 screws 6 If more liner needs to be used to reach the replace couple them together as illustrated The vent system must be supported approximately every 3 feet...

Страница 16: ...erminal sleeves engage into the vent pipes and sealant Secure the terminal to the exterior wall and make weather tight by sealing with caulking not supplied Theairterminalmountingplatemaybe recessed i...

Страница 17: ...h a 5 collapsed telescopic pipe to the last section of rigid piping Secure with screws and seal Repeat using a 8 telescopic pipe 10 Run a bead of high temperature sealant W573 0007 not sup plied Mill...

Страница 18: ...is positioned and the vent system is installed Use 2x4 s and frame to local building codes FIGURES 33 It is not necessary to install a hearth extension with this replace system When roughing in the r...

Страница 19: ...Centre the nailing tab vertically on the corner post Figure 36 a Drill through the centre of the top and bottom slots in the nailing tab Secure using the two sheet metal screws supplied This allows t...

Страница 20: ...clips into the slots located at the bottom left and right corners of the unit To remove the louvres pull the back tabs of the clips forward while push ing the louvre assembly back Lift the clip B HING...

Страница 21: ...g embers for a maximum glowing effect Log colours may vary During the initial use of the replace the colours will become more uniform as colour pigments burn in during the heat activated curing proces...

Страница 22: ...ll automatically start approxi mately 10 minutes after lighting the fireplace and will run for ap proximately 30 45 minutes after the fireplace has been turned off Use of the fan increases the output...

Страница 23: ...valve has an interlock device which will not al low the pilot burner to be lit until the thermocouple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighti...

Страница 24: ...e gasket Adjust the pilot screw to provide properly sized ame Turn in a clockwise direction to reduce the gas ow Air shutters have been factory set open according to the chart below These settings are...

Страница 25: ...LANT 39 W175 0166 5 COUPLER 39 W175 0002 8 COUPLER 40 L42K LOUVRE KIT UPPER LOWER BLACK 40 L42PB LOUVRE KIT UPPER LOWER POLISHED BRASS 40 L42SS LOUVRE KIT UPPER LOWER BRUSHED STAINLESS STEEL 41 GDOI42...

Страница 26: ...26 W415 0381 H 12 07 07...

Страница 27: ...le and valve connection replace thermocouple replace valve Faulty valve replace Pilot burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defec tive co...

Страница 28: ...door gasketing is not broken or missing and that the seal is tight check that both 5 and 8 vent liners are free of holes and well sealed at all joints check that minimum rise per foot has been adhered...