background image

display video stream data found within the network to 
which the touchscreen is connected.  This feature is 
designed to operate within the iSeeVideo system.  
See 

http://www.napcosecurity.com/video.html 

for more 

information.  

 

Configure Wireless Camera:

  Allows the 

touchscreen to remotely change the wireless settings 
of the selected camera.  When this feature is selected, 
be aware that the network path from the touchscreen 
to the IBR-ZREMOTE / StarLink Connect radio and to 
the camera may take several seconds to be estab-
lished.  

Note:

  When selected, a popup appears, that 

reads: 

 

"

Please make sure to first connect an Ethernet 

cable to the router and to then connect power to 
the camera.  Do you wish to proceed with Wireless 
Camera Configuration?

 

1.  The camera must be powered and wirelessly con-

nected to the network before proceeding.   

2. Tap 

Yes 

to proceed or 

No 

to exit without saving 

any changes.  If you tap 

Yes

, the touchscreen will 

scan the network and all available cameras will be 
listed (by IP address) in the Camera List that ap-
pears.  Tap to select a camera in the list, and a 

Configure Wireless Camera 

popup appears, 

allowing you to either Lock or Unlock the selected 
camera.  Locking the camera will ensure a perma-
nent connection between the camera and the 
touchscreen. 

3.  Select either the 

Lock 

or 

Unlock 

radio button, and 

tap 

Configure 

to proceed or tap 

Cancel 

to exit with-

out saving changes.   

Camera Manual Discovery:

  Allows you to browse 

for and select to use a specific camera attached to the 
iBridge network using the touchscreen.  The following 
two steps ("

Select

…" and "

Discover

…" shown below 

are required: 

 

1. 

Select camera to discover:

  (Step 1):  Tap to 

select the camera you wish to discover and capture 
its video stream data.   

2. 

Discover IP Camera:

  (Step 2):  Tap to initiate 

the network scanning process to discover the se-
lected camera.  Upon discovery, the video will be 
available for display from the touchscreen Home 
Screen (

Video 

button).   

 

Launcher

 

 

(Reserved for NAPCO use only) 

 

Home

 

Weather Options

 - Local weather reports can be displayed 

on the Home Screen.

 

 Refresh 

Frequency:

  Tap to set how often to auto-

matically update the weather report feed.  Selections 
include 5, 10, 15, 20, 30, 40, 50, 70, 80, 90 and 100 
minutes.  More frequent updates increase data use and 
slightly decrease battery life between charges.

 

 Weather 

Feed:

  Check to display a weather report 

feed on the Home Screen.  Uncheck to remove the 
weather feed from the Home Screen.  

Note:

  To cus-

tomize the weather report feed to a particular Zip 
Code, see the following menu entries below. 

 

Zip code entry: 

Check to associate the weather 

report feed to the area of the United States specified 
by the Zip Code entered in the field below.  Uncheck 
to disassociate the weather feed from this Zip Code. 

 

Zip Code: 

Tap to set the Zip Code to which the 

Weather Feed is associated. 

Update Z-Remote Clock

 - Synchronizes the IBR-

ZREMOTE module or StarLink radio internal clock 
with the same time as the IBR-TOUCH / IBR-TOUCH-
WL. 

Lock Display on Keypad View

 - Enabled (checked) 

when "Keypad Only" is selected in the Setup Wizard 
(see below).  When enabled, pressing 

Security

 in the 

Home Screen immediately displays the virtual security 
system Gemini keypad, and not the intermediary "pie 
wedges" that are displayed when "Full Functionality" 
is selected in the Setup Wizard.   

Set Keypad as the Only View

 - When enabled, pressing 

the 

Home

 button immediately and continually displays 

the virtual security system Gemini keypad.  

Note:

  The 

User Setting "

Enable KeySwitch Arming

" (detailed 

above) must first be disabled.   

 

Modify Z-Wave Settings

 

 

For dealers who wish to disallow customer changes to the 
home automation Z-Wave system, unchecking (disabling) 
this setting disables the 

User Settings 

menu feature named 

"

Automation Management (z-wave)

".  Conversely, check 

this setting to enable the 

User Settings 

menu feature named 

"

Automation Management (z-wave)

", allowing control of 

the Z-Wave home automation components within the system 
using the "

User Settings

" menu (where an touchscreen Deal-

er Settings password is not required).   

 

Automation Management (z-wave)

 

 Opens 

the 

Automation Management

 screen, allowing the 

configuration of Z-Wave devices, including the assignment of 
devices to Groups, the creation of Z-Wave Events, etc.  See 
the 

Using your iBridge

®

 IBR-TOUCH Series Z-Wave

®

 

Home Automation System

 (OI394) for more infor-

mation.   

 

Emergency Button

 

 

Check to enable the "

E

" (Emergency) button on the IBR-

TOUCH / IBR-TOUCH-WL Home Screen.  If unchecked, 
although the "

E

" (Emergency) button will appear on the 

Home Screen, it will be disabled and the message, 
"

Permission Denied.  Please Contact Dealer.

" will appear 

when tapped. 

 

Change Login URL

 

 

Not Used; do not change this selection.   

(

continued from previous page

 

Dealer Settings Menu

 

Содержание IBR-TOUCH

Страница 1: ...wer limited 12V power supply for each touchscreen is required see wir ing diagrams Features CPU Quad core processor up to 1 6GHz Wi Fi 802 11b g n with integral antenna LCD Size 7 inch digital screen...

Страница 2: ...ning with the setting Connect using Wi Fi Only enabled and thus is acting as a model IBR TOUCH WL In addition the touchscreen must be connected to the same network as the IBR ZREMOTE or StarLink Conne...

Страница 3: ...VERVIEW with the IBR TOUCH only Keypad Only Mode KEYPAD BUS BROADBAND MODEM CONTROL PANEL STANDARD KEYPAD Internet RED BLACK GREEN YELLOW Power Supply IBR TOUCH Power Supply If the sys tem standby cur...

Страница 4: ...BLACK GREEN YELLOW ISEE WAP CONTROL PANEL IBR TOUCH WL ISEE WAP Wireless Panel Interface communicates between Internet Gemini Control Panel through the 4 wire keypad bus the IBR TOUCH Touchscreen Tabl...

Страница 5: ...terior Bypass Stay Mode Easy Exit can be initi ated by pressing and holding the Disarm pie wedge button Easy Exit restarts the Exit delay the top ban ner on the touchscreen changes to read ARMING STAY...

Страница 6: ...d drive memory stick etc and you wish to use the USB socket lo cated on the side of the IBR TOUCH IBR TOUCH WL to re install the firmware Note The update file must be placed in a folder named napco ca...

Страница 7: ...lightly decrease battery life between charges Weather Feed Check to display a weather report feed on the Home Screen Uncheck to remove the weather feed from the Home Screen Note To cus tomize the weat...

Страница 8: ...e default setting is never Note When this feature is ena bled and the screen dims the IBR TOUCH also en ters sleep mode an inactive state to save power To re awaken simply touch the screen or a non sc...

Страница 9: ...l interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televis...

Страница 10: ...ss the ON OFF button to save PROGRAMMING WHEN USED WITH THE IBR ZREMOTE 5 Press Reset twice to exit Dealer Program Mode Veri fy the keypad display reads E09 00 Cold Start To cold start the GEM P3200 G...

Страница 11: ...if all zones are closed UPDATING THE TOUCHSCREEN FIRMWARE WITH USB DRIVE To update the touchscreen firmware with a USB drive the update zip file must be located in the top root directory the top root...

Страница 12: ...HEN PRINTING OR PHOTO COPYING A TEMPLATE ALWAYS SELECT PRINTING OPTIONS TO ENSURE THAT COPIES ARE PRODUCED WITHOUT SIZE ADJUSTMENTS VERIFY THE DIMENSIONS OF THIS BOX ARE 2 000 X 2 000 INCHES 0 010 E N...

Отзывы: