GEM

-

TOUCH 

K Style 

Keypad Operating Guide 

 

25

 

the  central  station  of  a  fire,  auxiliary, 

or  police  emergency  (also  audible 

within the premises).  See page 10.  

 

Partitioned System

 

-

  A  system  that  has 

been  subdivided  into  independent 

subsystems (called "Areas").  Up to 8 

Areas permitted.  

 

Priority Arming

 

-

  When  attempting  to 

arm the system with a faulted zone, a 3

-

second  tone  will  sound  and  the 

TROUBLE 

icon  will  appear,  indicating 

that the zones must be secured before 

the system can be armed.  

 

Report 

-

  A  transmission  to  a  central 

station  notifying  of  a  change  in  the 

status  of  the  system  (alarm,  trouble, 

low battery, etc.).

 

RF  Low  Battery

 

-

  (Wireless  systems 

only) Weak transmitter battery.

 

RF  Supervisory 

 

-

  (Wireless  systems 

only)  Periodic  test  report  from  a 

transmitter (if a report is not received 

on  time,  a  supervisory

-

failure  system 

trouble will result).

 

Ringback 

-

 A beep after arming verifying 

the  central

-

station's  receipt  of  a 

closing ("arming") report.

 

Service  /  Maid  Code

 

-

  A  User  Code 

intended for temporary use.

 

Sounder

 

-

  A  local  warning  device  at 

each  keypad  to  alert  that  (a)  entry 

delay has started; (b) an attempt was 

made  to  arm  with  a  zone  in  trouble; 

(c)  a  Day

-

Zone  condition  exists  (see 

Zones:    Day  Zone);  (d)  10  seconds 

exit  time  remaining;  (e)  invalid  code 

entered;  or  (f)  central  station

-

acknowledged 

arming 

(see 

Ringback).

 

System  Trouble 

-

  A  problem  (low 

battery,  power  failure,  etc.)  detected 

in the system.

 

Trouble

 

-

 A zone fault.  For example, an 

open  door,  window,  or  other  problem 

that may prevent arming.  

 

User Code

 

-

  Your  personalized  code  for 

arming  and  disarming  the  system.  

Used  also  for  entering  System  Set-

tings.  It may contain up to six digits.

 

Zones

 

-

 Independent circuits that protect 

specific  parts  of  the  premises,  such 

as:

 

• 

Auto

-

Bypass Zone

:    A  zone  that  will 

be  automatically  bypassed  from  the 

protection  system  if  it  is  in  trouble 

(faulty) when the system is armed.

 

• 

Burglary Zone

:  Detects intrusion.

 

• 

Exit/Entry Follower Zone

:    Provides 

exit  and  entry  delay  for  interior 

devices.  Entry delay only occurs if re

-

entry  takes  place  through  the  normal 

exit/entry door first.

 

• 

Fire  Zone

:    Detects  fire  alarms  or 

trouble conditions.

 

• 

Interior Zones

:    Circuits  within  the 

premises,  usually  including  space

-

protection devices, interior doors, etc.; 

but  not  exterior  doors  or  windows.  

(Two groups of Interior Zones may be 

programmed for each Area).

 

• 

Selective

-

Bypassed Zone

:    A  zone 

that  can  be  individually  bypassed  by 

tapping 

Bypass 

followed  by  the  zone 

number.

 

• 

24

-

Hour Zone

:   A  zone  that is armed 

and  ready  at  all  times  to  respond  to 

an emergency situation.

 

G L O S S AR Y

 

Содержание Gemini GEM-TOUCH K Series

Страница 1: ...ypad Operating Guide 1 OPERATING GUIDE for your Gemini GEM TOUCH 4 3 Full Color Security Touchscreen K Style Keypad NAPCO 2021 OI426LF 9 21 GEM TOUCH Home Screen Tap Hold down Tap Hold down SYSTEM REA...

Страница 2: ...dards To assure optimum safety and security familiarize yourself with this equipment Periodically check its condition and state of readiness by testing it at least once a week in both the AC battery a...

Страница 3: ...G USER CODES 21 KEYPAD SYSTEM SETTINGS GEARS ICON 23 GLOSSARY 24 SYSTEM TROUBLE ERROR CODES 26 TROUBLESHOOTING 28 FCC STATEMENT 29 NAPCO LIMITED WARRANTY 32 TO SILENCE AN ALARM See pages 11 and 12 for...

Страница 4: ...ating Guide Tap Hold down SYSTEM READY 1 09 14 28 8 15PM Tap Hold down K SERIES KEYPAD CONTROLS INDICATORS see next page 1 2 6 8 19 3 18 9 17 16 5 7 11 4 14 1 2 3 4 5 6 7 8 9 Arm Stay Arm Away 0 Clear...

Страница 5: ...n Arms all zones in the system 11 Emergency Buttons Signal an audi ble emergency by tapping the Home screen s gold E button then Tap hold down Panic for a police Emergency Tap hold down Aux for an aux...

Страница 6: ...combinations of icons may appear on the left side of the Home screen Zones Bypassed Appears when zone s are bypassed see Selectively Bypassing Zones on page 7 Fire Appears during a Fire Alarm When Pul...

Страница 7: ...way Selectively Bypassing Zones If you cannot locate or repair a faulted zone it can be removed from the system or bypassed To bypass the zone s from the system start at the Home screen tap Bypass and...

Страница 8: ...of Areas in my system ____ In a system that has been partitioned into Areas one of the Areas may be armed while the others remain disarmed To arm a different Area 1 In the Home screen take note of the...

Страница 9: ...at the end of the exit delay thus arming STAY allowing you to safely move within the premises If you arm AWAY do not exit and the system automatically reverts to armed STAY then you later exit the Int...

Страница 10: ...ergency Fire Emergency programmed YES NO Easy Exit Optional Easy Exit programmed YES NO Your system may have been programmed for Easy Exit which allows you to exit the premises while the system is arm...

Страница 11: ...ntruder may still be on the premises leave immediately and call authorities from a neighbor s telephone To silence an audible alarm 1 Tap PRESS TO DISARM shown above enter your User Code and tap Disar...

Страница 12: ...r Code and tap Disarm to silence the alarm Check the smoke detector s If a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down...

Страница 13: ...se escape procedures with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals es...

Страница 14: ...14 GEM TOUCH K Style Keypad Operating Guide FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Страница 15: ...not always detect fires because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors wi...

Страница 16: ...ing mode if no activity is detected for longer than one minute Activate Bell Test Activates the alarm sounder while disarmed for about 2 seconds and performs a battery test If the alarm does not sound...

Страница 17: ...is open at end of the test no report is sent If a 24 hour zone is tripped and not restored during Fault Find when Fault Find ends the zone will display as Faulted on the keypad display When Fault Find...

Страница 18: ...system events scroll back using the Prior button Delay Arming 1 4 hours Your system may be set to arm automatically after a delay period of 1 to 4 hours To Delay Arm the system With the function To Ar...

Страница 19: ...received NORMAL Transmitter s zone normal FAULT Transmitter s zone open LOBATT Transmitter battery low TAMPER Transmitter case open S FAIL Supervisory failure test transmission not received within pro...

Страница 20: ...r Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report restores must be restored first then the control pan el armed and disa...

Страница 21: ...ser Code you use to arm and dis arm then tap Enter The Function Menu screen appears 3 Tap Up Down until Activate Program Y N appears then tap Enter The SYSTEM SETTINGS screen appears 4 Tap User Codes...

Страница 22: ...he User Code field will display the User Code Exiting the User Program Mode When you have completed editing or reviewing User Codes tap Exit Notes When in the USER CODEs screen the ARMED and STATUS li...

Страница 23: ...t ment Tap hold down this button to activate the screen calibration utility that guides you through the steps need ed to translate the keypad touchscreen coordinates into true display coordinates LED...

Страница 24: ...passes all Interior Zones simultaneously to al low free movement within the premises while armed perimeter zones is main tained a violation of any perimeter zone will cause an instant alarm Battery Ba...

Страница 25: ...exists see Zones Day Zone d 10 seconds exit time remaining e invalid code entered or f central station acknowledged arming see Ringback System Trouble A problem low battery power failure etc detected...

Страница 26: ...been a recent power fail ure the battery may be partially de pleted and must be recharged by the control panel The control panel per forms an automatic test of the battery every 24 hours at which tim...

Страница 27: ...tton RR 4BKEYFOB uses a 3V Lithium coin cell battery replace with type CR2032 or Duracell DL2032 only The 1 button RR 1BUTTON uses two Energizer 386 1 5V silver oxide cells the unit will also flash it...

Страница 28: ...ouble Tap hold down Reset enter your User Code and tap Enter You will now be able arm to the system but the trouble must be fixed as soon as possible See Page 8 26 The Fire Alarm is sounding and I don...

Страница 29: ...icular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the...

Страница 30: ...30 GEM TOUCH K Style Keypad Operating Guide NOTES...

Страница 31: ...GEM TOUCH K Style Keypad Operating Guide 31 NOTES...

Страница 32: ...rged herein or are expressly cancelled NAPCO neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability con...

Отзывы: