background image

2

 

GEM

-

TOUCH 

K Style 

Keypad Operating Guide

 

The 

Gemini  GEM

-

TOUCH 

4.3"  Full 

Color  Security  Touchscreen  Keypad

 

is  a  "

smart"

,  interactive,  menu

-

driven 

touch keypad designed for your 

Napco 

Gemini 

system.  The keypad has a 4.3" 

color LCD display to show the status of 

your system.

 

This 

booklet 

contains 

important 

information about the operation of your 

system  with  your  keypad.    Read  it 

carefully  and  keep  it  handy  for  future 

reference.    Check  the  Glossary  for  an 

explanation  of  terms  that  may  be 

unfamiliar to you.

 

You'll probably find subjects mentioned 

in this booklet that do not apply to your 

system.    The  Gemini  cellular  security 

system  has  such  a  wide  variety  of 

features  that  few  security  systems,  if 

any,  will  ever  need  them  all.    Your 

alarm 

professional 

has 

chosen 

appropriate  features  for  your  particular 

needs.

 

 

Regardless  of  how  your  system  has 

been  configured,  rest  assured  that  it 

has  been  carefully  designed  and 

engineered  to  the  highest  industry 

standards.    To  assure  optimum  safety 

and  security,  familiarize  yourself  with 

this  equipment.    Periodically  check  its 

condition  and  state  of  readiness  by 

testing  it  at  least  once  a  week  in  both 

the  AC/battery  and  battery

-

only  modes 

(ask  your  alarm  professional  how  to 

make these tests).  

 

 

I N T R O D U C T I O N

 

Test your sounding device and backup battery

 

 

1.

 

While disarmed, tap 

Menu

.

 

2.

 

In the list of menu items, tap 

Up 

or 

Down 

until 

ACTIVATE 

BELL TEST

 is highlighted.  

 

3.

 

Tap 

Enter 

to  execute  the  test.    The  alarm  will  sound  for 

about two seconds.  

 

• 

If the alarm does not sound, call for service.

 

• 

If the battery is low, a system trouble "

E

-

02

" will appear 

in the keypad display.  Allow 24 hours for the battery to 

recharge.    If  the  trouble  continues,  call  your  alarm  in-

staller for service.  

 

Test your central station communicator

 

(Telephone Test programmed

YES  

NO)  

 

 

1.

 

While disarmed, tap/hold

-

down 

Menu

.

 

2.

 

Enter your User Code and tap 

Enter

.  

 

3.

 

Tap 

Up 

or 

Down 

until 

Digital Dialer Test

 is highlighted.

 

4.

 

Tap 

Enter 

to send a test code to the central station.

 

• 

If the test is not successful, "

E

-

03

" will display, indicating 

a communication failure.  Call for service.

 

IMPORTANT 

-

 TEST YOUR SYSTEM WEEKLY

 

Содержание Gemini GEM-TOUCH K Series

Страница 1: ...ypad Operating Guide 1 OPERATING GUIDE for your Gemini GEM TOUCH 4 3 Full Color Security Touchscreen K Style Keypad NAPCO 2021 OI426LF 9 21 GEM TOUCH Home Screen Tap Hold down Tap Hold down SYSTEM REA...

Страница 2: ...dards To assure optimum safety and security familiarize yourself with this equipment Periodically check its condition and state of readiness by testing it at least once a week in both the AC battery a...

Страница 3: ...G USER CODES 21 KEYPAD SYSTEM SETTINGS GEARS ICON 23 GLOSSARY 24 SYSTEM TROUBLE ERROR CODES 26 TROUBLESHOOTING 28 FCC STATEMENT 29 NAPCO LIMITED WARRANTY 32 TO SILENCE AN ALARM See pages 11 and 12 for...

Страница 4: ...ating Guide Tap Hold down SYSTEM READY 1 09 14 28 8 15PM Tap Hold down K SERIES KEYPAD CONTROLS INDICATORS see next page 1 2 6 8 19 3 18 9 17 16 5 7 11 4 14 1 2 3 4 5 6 7 8 9 Arm Stay Arm Away 0 Clear...

Страница 5: ...n Arms all zones in the system 11 Emergency Buttons Signal an audi ble emergency by tapping the Home screen s gold E button then Tap hold down Panic for a police Emergency Tap hold down Aux for an aux...

Страница 6: ...combinations of icons may appear on the left side of the Home screen Zones Bypassed Appears when zone s are bypassed see Selectively Bypassing Zones on page 7 Fire Appears during a Fire Alarm When Pul...

Страница 7: ...way Selectively Bypassing Zones If you cannot locate or repair a faulted zone it can be removed from the system or bypassed To bypass the zone s from the system start at the Home screen tap Bypass and...

Страница 8: ...of Areas in my system ____ In a system that has been partitioned into Areas one of the Areas may be armed while the others remain disarmed To arm a different Area 1 In the Home screen take note of the...

Страница 9: ...at the end of the exit delay thus arming STAY allowing you to safely move within the premises If you arm AWAY do not exit and the system automatically reverts to armed STAY then you later exit the Int...

Страница 10: ...ergency Fire Emergency programmed YES NO Easy Exit Optional Easy Exit programmed YES NO Your system may have been programmed for Easy Exit which allows you to exit the premises while the system is arm...

Страница 11: ...ntruder may still be on the premises leave immediately and call authorities from a neighbor s telephone To silence an audible alarm 1 Tap PRESS TO DISARM shown above enter your User Code and tap Disar...

Страница 12: ...r Code and tap Disarm to silence the alarm Check the smoke detector s If a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down...

Страница 13: ...se escape procedures with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals es...

Страница 14: ...14 GEM TOUCH K Style Keypad Operating Guide FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Страница 15: ...not always detect fires because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors wi...

Страница 16: ...ing mode if no activity is detected for longer than one minute Activate Bell Test Activates the alarm sounder while disarmed for about 2 seconds and performs a battery test If the alarm does not sound...

Страница 17: ...is open at end of the test no report is sent If a 24 hour zone is tripped and not restored during Fault Find when Fault Find ends the zone will display as Faulted on the keypad display When Fault Find...

Страница 18: ...system events scroll back using the Prior button Delay Arming 1 4 hours Your system may be set to arm automatically after a delay period of 1 to 4 hours To Delay Arm the system With the function To Ar...

Страница 19: ...received NORMAL Transmitter s zone normal FAULT Transmitter s zone open LOBATT Transmitter battery low TAMPER Transmitter case open S FAIL Supervisory failure test transmission not received within pro...

Страница 20: ...r Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report restores must be restored first then the control pan el armed and disa...

Страница 21: ...ser Code you use to arm and dis arm then tap Enter The Function Menu screen appears 3 Tap Up Down until Activate Program Y N appears then tap Enter The SYSTEM SETTINGS screen appears 4 Tap User Codes...

Страница 22: ...he User Code field will display the User Code Exiting the User Program Mode When you have completed editing or reviewing User Codes tap Exit Notes When in the USER CODEs screen the ARMED and STATUS li...

Страница 23: ...t ment Tap hold down this button to activate the screen calibration utility that guides you through the steps need ed to translate the keypad touchscreen coordinates into true display coordinates LED...

Страница 24: ...passes all Interior Zones simultaneously to al low free movement within the premises while armed perimeter zones is main tained a violation of any perimeter zone will cause an instant alarm Battery Ba...

Страница 25: ...exists see Zones Day Zone d 10 seconds exit time remaining e invalid code entered or f central station acknowledged arming see Ringback System Trouble A problem low battery power failure etc detected...

Страница 26: ...been a recent power fail ure the battery may be partially de pleted and must be recharged by the control panel The control panel per forms an automatic test of the battery every 24 hours at which tim...

Страница 27: ...tton RR 4BKEYFOB uses a 3V Lithium coin cell battery replace with type CR2032 or Duracell DL2032 only The 1 button RR 1BUTTON uses two Energizer 386 1 5V silver oxide cells the unit will also flash it...

Страница 28: ...ouble Tap hold down Reset enter your User Code and tap Enter You will now be able arm to the system but the trouble must be fixed as soon as possible See Page 8 26 The Fire Alarm is sounding and I don...

Страница 29: ...icular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the...

Страница 30: ...30 GEM TOUCH K Style Keypad Operating Guide NOTES...

Страница 31: ...GEM TOUCH K Style Keypad Operating Guide 31 NOTES...

Страница 32: ...rged herein or are expressly cancelled NAPCO neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability con...

Отзывы: