Trillium Compact User Guide
16889R5
2014-03-04
51
Chapter 10
Connector and Cables
10.1 14-Pin Trillium Compact Connector and Cables
10.1.1 Pinout for 14-Pin Trillium Compact Connector
Trillium Compact model numbers TC120-SV1, TC20-SV1 (surface vault), TC120-PH1, and
TC20-PH1 (surface vault or posthole) are equipped with a 14-pin male military circular type
hermetic connector.
provides the connector pinout.
Table 10-1
Pinout for 14-pin Trillium Compact connector
Pin
Name
Function
Type
B
X+/U+
X axis output (east)
40 Vpp differential
C
X-/U-
F
Y+/V+
Y axis output (north)
H
Y-/V-
L Z+/W+
Z axis output (vertical)
M
Z-/W-
K
CAL_SIG
Calibration signal input
See
Table 9-3 “Calibration circuit
R
MAXIMUM
MASS POSITION
Mass position of the axis with the
highest absolute mass position
-4 V to +4 V analog
D
CTRL/RX
Calibration enable, Short
Period/Long Period mode*
-OR-
Serial RS-232 receive input
* See
Section 4.3 “Digital Control Input
configuration and functionality.
Digital: Active-high 12 V to 15 V
(low is equal to open or 0 V)
Serial receive: +5 V/0 V to
+15 V/-15 V
J
UVW/TX
Input: Enable UVW outputs
instead of XYZ factory default
Output: Serial RS-232 transmit
Digital: Active-high 5 V to 15 V
(low is equal to open or 0 V)
Serial transmit: ±3.7 V
E
AGND
Analog ground
N/A
P
+PWR
Power input
9 V to 36 V DC isolated
N
-PWR
Power return
A
DGND
Digital ground
N/A
shell
CHASSIS
For shielding and safety
N/A