Chapter 1
Getting Started
Trillium Compact User Guide
16889R5
2014-03-04
7
Models TC120-PH1 and TC20-PH1 (surface vault or posthole)
Cable – Trillium
Compact Posthole
Cable Waterproof
Shroud to
Nanometrics
Digitizer
17769-1M
17769-3M
17769-5M
17769-10M
17769-15M
17769-25M
17769-35M
17769-50M
A robust IP68 rated cable with a polyurethane jacket that is
suitable for buried deployments. The cable has a 14-pin
Trillium Compact connector on one end and the connector
for a Nanometrics digitizer on the other end. Ideal for
posthole installations, the waterproof shroud that covers the
Trillium Compact connector allows Trillium Compact model
numbers TC120-PH1 and TC20-PH1 to be submerged to
depths of up to 50 m for an indefinite period of time.
Standard cable lengths are 1 m, 3 m, 5 m, 10 m, 15 m, 25 m,
35 m, and 50 m.
See
for information
and instructions on using this product to bring the unit rating
to IP68.
See
“Performing a Posthole Installation”
for
instructions on installing model numbers TC120-PH1 and
TC20-PH1 as posthole seismometers.
Adjustable Feet Kit
17245
A kit including three adjustable locking feet that should be
used on model numbers TC120-PH1 and TC20-PH1 instead of
the default fixed studs in a surface vault installation.
Models TC120-PH2 and TC20-PH2 (posthole)
Cable – Trillium
Compact Posthole
to Nanometrics
Digitizer, Molded
17768-10M
17768-30M
A cable with a molded neoprene connector on one end
that connects to the Trillium Compact Posthole connector
and a connector on the other end for connecting to a
Nanometrics digitizer. The cable features a robust neoprene
cable jacket that is suitable for buried deployments.
In addition to connecting the analog inputs, power, and
control line signals to the digitizing and data logging
features of the digitizer, this cable also provides access to
the Web interface of the seismometer through the Web
interface of the digitizer.
Cable – Trillium
Compact Posthole
to Open End,
Molded
17356-5M
17356-10M
17356-30M
17356-70M
A cable with a molded neoprene connector on one end
that connects to the Trillium Compact Posthole connector
and is open-ended on the other end.
In addition to connecting the analog inputs, power, and
control line signals to the digitizing and data logging
features of the digitizer, this cable also provides access to
the Web interface of the seismometer through the Web
interface of the digitizer.
Models TC120-PH2, TC20-PH2 (posthole), TC120-PH1, and TC20-PH1 (surface vault or posthole)
Bubble Level
MSC0225
For applications where precise levelling is required, the
bubble level is placed on top of the seismometer during
installation.
Table 1-1
List of cables and accessories
Name
Part Number
Description