OPERATING AND MAINTENANCE MANUAL
Chapter 3
- Technical data
NRC0020-0200 UL
The data in this manual are not binding and may be changed by the manufacturer without notice.
Reproduction of this manual, even partial, is strictly prohibited.
C
HAPTER
3
T
ECHNICAL
DATA
3 . 1
D a t a p l a t e a n d m e a n i n g o f a b b r e v i a t i o n s
The main technical data of the unit are indicated on the data plate::
The following abbreviations are present on the data plate and wiring diagram:
3 . 2
P e r f o r m a n c e d a t a
CAUTION
The performance of the dryer (dew point, power consumption, pressure drops, etc.) depends mainly on the flow rate and pressure of the
compressed gas to be dried and on the condenser cooling fluid temperature (ambient temperature).
These data, which are usually defined at the time of the offer, constitute the basic point of reference in relation to dryer performance.
3.2.1 Sound Level Measurements
The noise emission values measured are below 70 dB(A).
MODEL and CODE
Identify the size of the unit and its type of construction.
MANUAL
Code number of the present manual.
SERIAL NUMBER
Unit serial number or manufacturing number.
YEAR OF CONSTRUCTION
Year of unit's final testing.
VOLTAGE/PHASES/FREQUENCY
Power supply characteristics.
SHORT CIRCUIT CURRENT
Short circuit current.
HIGHEST MOTOR FULL LOAD
AMPERAGE
Maximum current input.
MAX CURRENT DRAW (I max)
Sum of FLA of all loads.
INSTALLED POWER (P max)
Sum of the maximum power input of all loads.
PROTECTION RATING
According to European standard UL508A and EN60529.
ELECTRICAL DIAGRAM
Identifies the electrical diagram number.
REFRIGERANT
Type of refrigerant charge with which the unit is filled.
REFRIGERANT CHARGE
Quantity of refrigerant supplied to circuit.
MAX. REFRIGERANT PRESS.
Refrigerant circuit design pressure.
MAX REFRIGERANT TEMP.
Refrigerant circuit design temperature.
USER CIRC. FLUID
Fluid cooled by the machine.
MAX. WORKING PRESSURE
User circuit maximum design pressure.
MAX TEMPERATURE
User circuit maximum design temperature - not to be confused with the maximum working
temperature, which is specified at the time of the offer.
SOUND PRESSURE LEVEL
Free field sound pressure level in hemispherical radiation conditions (open field) at a distance of 1m
(39.37in) from the condenser side of the unit and a height of 1.6m (63.0in) from the ground.
AMBIENT TEMPERATURE
Cooling air minimum and maximum temperature values.
WEIGHT
Approximate weight of the unit without packaging.
CONDENSER COOLING FLUID
Fluid used by the machine to cool the condenser (this information is not given if the machine
condenser is air-cooled).
MAX. WORKING PRESSURE
Condenser cooling circuit maximum design pressure (this information is not given if the machine
condenser is air-cooled).
MAX TEMPERATURE
Condenser cooling circuit maximum design temperature (this information is not given if the machine
condenser is air-cooled).
FLA
full load amperage;
PMAX
maximum power;
ILR
locked rotor current;