DanVex’s 

DD, DD-F, DD-FS, DD-FSR Series 

DUCTED DEHUMIDIFIER 

 

User’s Manual 

 
 
 
 

 

 

 

 

KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

 

 

Thank you for choosing our dehumidifier. This owner’s manual will provide you with 

valuable information necessary for the proper care and maintenance of your new 

dehumidifier. Please take a few moments to read the instructions thoroughly and 

familiarize with all the operational aspects of this dehumidifier. This unit removes 

excessive moisture from the air to create a more comfortable environment. 

Содержание DD Series

Страница 1: ...ifier This owner s manual will provide you with valuable information necessary for the proper care and maintenance of your new dehumidifier Please take a few moments to read the instructions thoroughl...

Страница 2: ...Delivery and storage 9 3 3 Inspection before installation 9 3 4 Moving machine 9 3 5 Installation Location 9 3 6 Ground Base 10 3 7 Ducting Connection 10 3 8 Ducting Connection Diagram example 11 3 9...

Страница 3: ...lter 24 5 3 Fan Motor 24 5 4 1 Maintenance during start of usage season 25 5 4 2 Maintenance during end of usage season 25 5 4 3 Maintenance of key components 25 5 4 4 Maintenance procedures 25 5 5 In...

Страница 4: ...Rights Reserved We reserve the rights of updating explaining all contents of manual involved Warning All electrical connections works must be done by local professionals according to relevant provisi...

Страница 5: ...ment to cool down at least 15 minutes before begin the maintenance service The machine panel should be closed at all time if maintenance work is not carried out Dehumidifier is limited to atmospheric...

Страница 6: ...to prevents clogging impurities in expansion valve or capillary Patented defrosting structure it brings stable operation of refrigeration system Hydrophilic membrane fin heat exchanger heat transfer e...

Страница 7: ...is is a delay protection for protecting the compressor Shutdown delay protection When the dehumidifier is power off the fans will keep running for 3 minutes to cool down the dehumidifier thus reducing...

Страница 8: ...Page 8 of 39 DD F Series...

Страница 9: ...properly to prevent dust frost and rain intrusion 3 3 Inspection before installation Unpack package and check machine If any damage is found please contact supplier manufacturer 3 4 Moving machine Pl...

Страница 10: ...ld be connected with the connection part on flange meanwhile the screw bolt is limited to within 20mm While connecting the ducting some notes as below x In order to reduce loss of static pressure do t...

Страница 11: ...Page 11 of 39 3 8 Ducting Connection Diagram example...

Страница 12: ...id Area No Blockage A B E D DD 26 26F 400mm 490mm 100mm 100mm DD 36 36F 500mm 600mm 100mm 100mm DD 56 56F 500mm 600mm 100mm 100mm DD 96 96F 600mm 650mm 100mm 100mm DD 136 136F 600mm 650mm 100mm 100mm...

Страница 13: ...on Drain pipe is a transparent hose please connect it as per the drawing as below It is strongly advised to install a U Trap with PVC pipe or any other pipe that are suitable This would help to allow...

Страница 14: ...ts as below Temperature and humidity detection devices should be installed above ground 1m 1 5m to ensure the device can detect the humidity of the dehumidifying area Detection device should be instal...

Страница 15: ...Page 15 of 39 3 15 Machine Picture Diagram EC Fan Compressor Heat Exchanger Filters Wiring Terminal Green Connector Controller To connect between Machine and Controller 3 Phase Protector Contactor...

Страница 16: ...ge g ge ge ge ge ge ge ge ge g g g g g g g g g ge g g g g g ge ge g g g g g ge g g g ge ge g g g g g g ge g ge e g ge e e e e e e ge e e e e ge g g g g g g g g g g g g g g g g g g g 1 1 1 16 1 16 16...

Страница 17: ...eration The controller provides functions to control the machine On Off Humidity Setting Fresh Air Valve On Off Adjust Fan Speed depending on models and available fan settings and many other functions...

Страница 18: ...n quick press or button it will help to adjust the fan speed Alternatively these functions can also be set by pressing the Operation Setting button to enter the Setting Menu 6 During Humidification fu...

Страница 19: ...e condition during auto mode before changing to manual mode 13 During manual mode press and hold for few second it will turn on the dehumidifying function Press UV button and hold for few seconds will...

Страница 20: ...the timer switch icon will appear at the same time Press and hold the clock button to set the Timer ON value Then press and to set Once is set press the setting button to confirm and continue with the...

Страница 21: ...n setting value 0 99 default value 50 and Note The minimum difference between the dehumidification value and the humidification value is always greater than 5 if the humidification value set at 60 the...

Страница 22: ...r value CRC16 1 byte 1 byte 1 byte N 2 bytes 2 bytes Slave 0x01 0x03 0x02 N 2 bytes CRC16 Setting Running status 0x01 Machine Condition 1 Indicate in operation 2 Start 0 Off 0x02 Fan Speed 1 3 3 level...

Страница 23: ...Function 1 Turn on Mixed Air valve 0 turn on Internal Circulation Valve Control 4 3 Safety Cautions Dehumidifier has high speed moving parts Before running make sure panel is closed correctly and no...

Страница 24: ...rmance of the equipment and at the same time may cause the compressor to start frequently under unnecessary defrost control It is recommended that the filter device is checked at least once a month Th...

Страница 25: ...pair center If the outdoor unit is rusted paint should be applied to the rusted area to prevent its enlargement while ensuring personal safety Special protective cover can be used to wrap the external...

Страница 26: ...functions of the controller are normal Determine if the wiring on the back of the controller is loose Check if the controller logic is accurate Main Control Board Check whether each function is norma...

Страница 27: ...nject refrigerant that is inconsistent or unqualified when installing or moving the machine If the refrigerant is inconsistent or unqualified it may cause problems such as poor operation malfunction m...

Страница 28: ...and gathers around the unit it may cause an explosion accident Do not connect in the middle of the wire When the connecting wire is not long enough please contact your local authorized service center...

Страница 29: ...lty analysis please refer to the circuit diagram and related materials provided There is a high voltage inside the unit Before taking any troubleshooting measures make sure that the unit s power is tu...

Страница 30: ...damaged 3 Poor connection in compressor circuit 4 Possibility of capacitor faulty 5 Possibility of compressor is overloaded 6 Possibility of compressor is damaged The fan does not rotate when the vent...

Страница 31: ...ct is not installed properly and the air volume is insufficient After installation commissioning and shutdown after a period of time water overflows from the machine 1 The machine is not equipped with...

Страница 32: ...zed by DanVex Oy c This warranty covers manufacturing defects and does NOT cover parts subjected to conditions of use outside of specifications in operation manual and those exposed to normal wear and...

Страница 33: ...Page 33 of 39 7 2 Wiring Diagram...

Страница 34: ...Page 34 of 39...

Страница 35: ...Page 35 of 39...

Страница 36: ...Page 36 of 39...

Страница 37: ...Page 37 of 39...

Страница 38: ...Page 38 of 39...

Страница 39: ...Page 39 of 39...

Отзывы: