background image

5

nitrogen gas generator

ECOGEN

2

5

2.  general information

This manual is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced 

to any electronic medium or machine readable form without prior consent in writing. It may not be distributed through the internet or 

computer bulletin board systems without prior consent.

2.1  document introduction

This manual provides factory prescribed maintenance procedures for the nitrogen generator. The procedures illustrated in this document 

are only to be performed by authorized personnel. For further information regarding the procedures outlined in this document contact the 

manufacturer before proceeding. 

2.2  general safety

No modifications must be made to the product. Any modifications may reduce the operational safety of the product and invalidate the 

manufacturer’s warranty. This could potentially result in damage to the product and serious personal injury.
For your own safety, when carrying out work on this product, all relevant national safety regulations must be complied with relating to 

pressurized and electrical systems. 
Only authorized, competent and trained personnel are permitted to work on this product. This user guide is intended solely for such 

personnel and is to be used only as a reference; it should not be used to replace conventional training.

2.3  packaging

All products are securely packaged in a specifically designed wooden packing box. The dryer will be held in a horizontal position by 

wooden struts; using straps to secure the product to the box base. The box top cover can be removed by removing the 4 fixing screws 

and lifting off in one piece.

2.4 

intended use of the product

The nitrogen generator is exclusively intended for the treatment of compressed air, which is free from bulk water, oil and solid matter 

constituents.

The product should be located within a building and protected from extreme conditions and weather. The nitrogen generator must be 

operated only in accordance with the data on the rating plate. Any operations that do not comply with those stated on the product 

rating label will render the warranty void

NOTES:

 

highlight important sections of 

information where particular care and 

attention should be paid.

CAUTIONS

: indicate any situation or 

operation that may result in potential 

damage to the product, injury to the user, 

or render the product unsafe.

annotations

WARNING

:

 This product can expose you to chemicals including lead, which is known to the 

State of California to cause cancer and/or birth defects or other reproductive harm. For more 

information, go to www.P65Warning.ca.gov.

Содержание ECO GEN2

Страница 1: ...User guide ECO GEN 2 nitrogen generator revision 2022 018 document 17 100 0693 2022 Air Gas Solutions LLC www n psi co uk...

Страница 2: ...uccessful business Your business needs to exceed your customers expectations to stand out from your competitors and our service must positively impact your business so you can be successful in doing s...

Страница 3: ...n factors 3 3 product dimensions 7 4 product overview 8 4 1 typical system layout 9 4 2 remote start stop control 10 4 3 start up procedure 11 4 4 shutdown procedure 4 5 control panel displays 12 5 ma...

Страница 4: ...purification solutions inc address 5509 David Cox Road Charlotte NC 28269 USA telephone 1 704 897 2182 internet www n psi com email support n psi com canada nano purification solutions inc address 7 P...

Страница 5: ...uct This user guide is intended solely for such personnel and is to be used only as a reference it should not be used to replace conventional training 2 3 packaging All products are securely packaged...

Страница 6: ...o the generator 3 1 flow rates model rated outlet flow for nitrogen purity outlet maximum oxygen content 99 9 0 1 99 5 0 5 99 1 98 2 97 3 96 4 95 5 Nm3 hr scfh Nm3 hr scfh Nm3 hr scfh Nm3 hr scfh Nm3...

Страница 7: ...nches mm inches mm inches mm inches mm inches ECO GEN2 090 1064 42 440 17 366 14 225 7 110 4 60 2 125 5 ECO GEN2 110 1391 55 440 17 366 14 225 7 110 4 110 2 125 5 ECO GEN2 130 1991 78 440 17 366 14 22...

Страница 8: ...ssure gauge 2 to buffer 1 BSPP or NPT 9 online column pressure gauge 3 from buffer 1 2 BSPP 10 compressed air inlet pressure gauge 4 nitrogen outlet 1 2 BSPP 11 purge flow control 5 mains inlet electr...

Страница 9: ...IMPORTANT It is essential that the system into which the generator is installed is fitted with a pressure limiting relief device This device should be installed between the compressor and the product...

Страница 10: ...contact 5 Green Wire 24V DC Output 6 Yellow Wire 24V DC Output To set up the Remote Start Stop control remove break the connection between the Black wires and green wires connect externally to a remot...

Страница 11: ...ol system will be able to operate fully 4 4 shutdown procedure Please ensure this procedure is followed when shutting down the generator Do not turn off the power to the generator Isolate all compress...

Страница 12: ...he generator has run in Economy mode 3 Start up Sequence During the start up sequence the screen will display Start up will be displayed until the half cycle count has met the de sired set point Colum...

Страница 13: ...nerator clean all surfaces that appear to have attracted unwanted contaminants always check all connections for leakage and secure seating ensure all loose parts are removed or secured to the generato...

Страница 14: ...er of your generator this can be found on the rating plate located top right hand side of the generator Service A Every 1 Year 12 Months Replace External Exhaust Silencers Service B Every 2 Year 24 Mo...

Страница 15: ...lencers 31 100 5011 Replacement Exhaust Silencers x2 Exhaust Silencers 31 100 5013 Replacement Exhaust Silencers x2 Exhaust Silencers 31 100 5150 Replacement Exhaust Valves x2 Exhaust Valves 31 100 51...

Страница 16: ...element failure to cycle Controller not functioning correctly Ensure the controller is powered up check the on screen column status to ensure it is powering the solenoid valves during operation Insuf...

Страница 17: ...REGULTOR FLOW CONTROLLER PURGE VALVES N2 OUTLET VALVE OUTLET PRESSURE SENSOR REGULATED OUTLET PRESSURE GAUGE ONLINE COLUMN PRESSURE GAUGE INLET B SOLENOID VALVE EXHAUST EXHAUST INLET A SOLENOID VALVE...

Страница 18: ...18 nitrogen gas generator ECOGEN2 7 1 wiring diagram Controller Box Earth Pin Enclosure Front Plate Earth Pin O2 Analyser options only Resistor 500...

Страница 19: ...nitrogen gas generator ECOGEN2 notes 19...

Страница 20: ...nitrogen gas generator ECOGEN2 notes 20...

Страница 21: ...nitrogen gas generator ECOGEN2 notes 21...

Страница 22: ...2182 support n psi com www n psi com nano purification solutions st catharines ontario canada tel 1 905 684 6266 support n psi com www n psi com nano purification solutions new bethlehem pennsylvania...