2
3. technical specification
specifications
standard
options
minimum operating pressure
6 barg (87 psig)
maximum operating pressure
10 barg (145 psig)
recommended operating temperature range
20 to 25°C (68 to 77°F)
design operating temperature range
5 to 50°C (41 to 122°F)
inlet air quality
-40°C pdp (-40°F pdp)
3°C pdp (37°F pdp)
power supply requirements
100 to 240V AC @ 50 or 60 Hz
24V DC
All generators should be proceeded by a coalescing filter regardless of oil or oil free applications, a 0.01mg/m1 grade
coalescing filter must be installed on the inlet to the generator.
3.1 flow rates
model
rated outlet flow for nitrogen purity outlet (maximum oxygen content)
99.9%
(0.1%)
99.5%
(0.5%)
99%
(1%)
98%
(2%)
97%
(3%)
96%
(4%)
95%
(5%)
Nm
3
/hr
scfh
Nm
3
/hr
scfh
Nm
3
/hr
scfh
Nm
3
/hr
scfh
Nm
3
/hr
scfh
Nm
3
/hr
scfh
Nm
3
/hr
scfh
ECO-GEN
2
090
1.4
49.4
2.2
77.7
2.7
95.3
3.7
130.6
4.6
162.4
5.3
187.1
5.9
208.3
ECO-GEN
2
110
2.4
87.7
3.4
120.0
4.3
151.8
5.8
204.8
7.2
254.2
8.4
296.6
9.4
331.9
ECO-GEN
2
130
4.0
141.2
5.6
17.7
7.1
250.7
9.6
339.0 12.0 423.7 13.9 490.8 15.5 547.3
Inlet Temperature Correction Factors
°C
5
10
15
20
25
30
35
40
45
50
°F
41
50
59
68
77
86
95
104
113
122
correction factor
0.8
0.9
0.94
1
1
0.98
0.95
0.9
0.85
0.72
Inlet Pressure Correction Factors
barg
6
7
8
9
10
psig
87
101
116
130
145
correction factor
0.88
1
1.10
1.20
1.20
3.2
correction factors
Содержание ECO GEN2
Страница 19: ...nitrogen gas generator ECOGEN2 notes 19...
Страница 20: ...nitrogen gas generator ECOGEN2 notes 20...
Страница 21: ...nitrogen gas generator ECOGEN2 notes 21...