© by N&W GLOBAL VENDING S.p.A.
37
05-2015 3625 01
sTaTIsTICs
All the machine operation data are stored in total and
relative counters that can be reset without losing total
data.
E
lEctroNic
couNtEr
D
isplay
tHE
ElEctroNic
couNtEr
An electronic counter is intended to store all the dispens
-
ing cycles you have performed since you last reset it in
an aggregated manner.
r
EsEt
tHE
ElEctroNic
couNtEr
You can reset the electronic counter.
D
isplay
vENDs
at
tHE
start
-
up
To enable / disable the display of the total number of dis
-
pensing cycles that have been made since you last reset
the statistics, while you are powering on the machine.
EvaDts
The two codes used to identify the machine and recog
-
nise the data transfer terminal are established by the
EVADTS (European Vending Association Data Transfer
System) communication protocol:
c
ommuNicatioN
protocol
Use this function to decide which communication proto
-
col to use for the communication of the data acquisition
device.
The communication protocols made available are:
DDcmp
ENHaNcED
with the following configurable parameters:
-
Pass code: it is a four-digit alphanumeric code (0-9;
A-F) that shall be the same as the one of the data
transfer terminal for identification.
Set to 0000 by default
-
Security code: it is an alphanumeric code for mutual
recognition between machine and EVA DTS terminal.
Set to 0000 by default
-
End of transmission: if enabled, it can recognise the
end-of-transmission signal sent to the last package and
interrupt data transmission.
DEx
/
ucs
No configurable parameter is expected for this protocol:
D
ata
traNsmissioN
The function is used to select which communication in
-
terface shall be used for data transmission. The following
interfaces are made available:
-
“RS232” and “IrDA”: for communication with acquisition
devices
-
“Always EVADTS” for communication with data acquisi
-
tion and transmission devices (telemetry)
typE
The function is used to choose how to manage the com
-
munication speed with data acquisition devices.
-
“ENHANCED”: the communication speed is auto
-
matically adjusted to the maximum speed the slowest
device can support
-
“FIXED”: the communication speed is fixed and it uses
the communication speed set up by means of the “ba
-
udrate” function
bauDratE
(
traNsmissioN
spEED
)
To set the transmission speed for communication (2400,
4800, 9600, 19200 bps).
Set to 2400 bps by default
c
oNNEctioN
If you activate this function, the machine will be waiting
for connection with a device in order to acquire EVADTS
data.
r
Efill
ENablE
For models with a data transmission system only.
The function is used to enable the request to enter the
“refill code” at the end of the power-on cycle of the ma
-
chine.
The “refill code” is a 4-digit code (1234 by default) used
to reset the counters that manage the “ending product”
pre-alarms sent by means of the data transmission
system.