© by N&W GLOBAL VENDING S.p.A.
34
05-2015 3625 01
p
HotocEll
paramEtErs
The machine can be fitted (as a standard or as an op
-
tion according to the models) with a device intended to
detect the passage of dispensed products by means of
photocells.
If no dispensing cycle is detected for a product, this
device will enable you to:
-
set a rotation time for the spiral beyond the limit switch,
to overcome any jam;
-
return the paid amount or not;
-
lock any further selection on the spiral in question.
D
ispENsiNg
compartmENt
lock
paramEtErs
The dispensing compartment can be fitted (as a stand
-
ard or as an option) with a lock device.
Use this function to decide whether to leave the com
-
partment:
-
"always free"
or whether to
-
“release it upon dispensing”.
The door is only released for a well-defined time interval
(programmable from 1 to 10 minutes) in the “release
upon dispensing” mode as soon as you request for a
product.
If the machine is equipped with an automatic opening
department, you can set up the opening time of the com
-
partment (0: automatic opening disabled or up to one
minute and a half).
ENErgy
saviNg
2 energy saving time bands can be programmed on a
weekly basis.
The days of the week are identified by a progressive
number (1=Monday, 2=Tuesday etc.)
The same time band can not include days of different
weeks.
If you should mistakenly set up overlapping time bands,
the machine will remain on for the shortest period.
When the equipment is in energy saving mode:
-
The glassfront is lit up.
-
The compressor continues to work.
-
The display shows the message "Out of order".
For example, if you wish to set up the Service Interrup
-
tion bands to operate the machine from 07.00 a.m. to
10.00 p.m. during the days of the week and to let it off
on Saturdays and on Sundays, you shall set up the time
bands according to the following table by using the cor
-
responding menu.
Day
1
2
3
4
5
6
7
band 1
start
00.00 00.00 00.00 00.00 00.00 00.00 00.00
end
07.00 07.00 07.00 07.00 07.00 23.59 23.59
band 2
start
22.00 22.00 22.00 22.00 22.00 00.00 00.00
end
23.59 23.59 23.59 23.59 23.59 00.00 00.00
m
acHiNE
ligHtiNg
out
of
sErvicE
To define whether to turn on or off the illumination of
the machine when the machine is out of service or the
“Energy saving” time band has tripped.
vm
sErial
NumbEr
The function is used to change the eight-digit numeric
code identifying the machine (00000000 by default).
p
rogrammiNg
tHE
opErator
coDE
When the display is set to the "Operator Code" function,
you can change the six-digit numeric code identifying
groups of machines (0 by default).
i
NstallatioN
DatE
The function is used to store the current system date as
the installation date.
The date is printed at the time of rolling out statistics.