ElECTRIC CoNNECTIoN
The machine is arranged for electrical operation at a
230-240 V∿ single-phase voltage and it is protected by
T6.3A fuses.
For connection make sure that the rating will comply with
the mains data, in particular that the supply voltage value
shall lie within the limits recommended for the connec-
tion points.
It is absolutely necessary to use a main switch
in compliance with the installation rules in force,
placed in an accessible position. It shall be featured
in such a way that it can support the maximum load
required as well as ensure complete disconnection
from the mains on the conditions of overvoltage
category III and, therefore, the protection of circuits
against earth faults, overloads and short-circuits.
The switch, the power socket and the corresponding
plug shall be located in an accessible position.
The electrical safety of the machine is only ensured
when the machine is correctly and efficiently grounded
according to the safety standards in force.
It is necessary to check this fundamental safety
requirement and, in case of doubt, to require pro-
fessionally qualified personnel to check the instal
-
lation carefully.
The supply cable is of a flexible type with a fixed plug.
If necessary, the connection cable shall be replaced by
qualified personnel only by using only flexible cables of
the H05 RN - F or H05 V V-F or H07 RN-F type, 3x1-1.5
mm² in cross-section.
It is forbidden to use adapters, multiple sockets
and/or extensions.
The manufacturer disclaims all responsibility for
any damage caused by the non-observance of the
precautions mentioned above.
1
2
3
Fig. 18
1- Small lift cover
2- Cable clamp
3- Supply cable