15 of 32
www.NabcoEntrances.com
SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual
Rev. 8-11-21
P/N C-00139
Optional Setting
Parameter
Range
Default
Description
DN 1558
Open fi rst,
Latch check is wide
Overlap Sim Pair
Opus Se ngs
Normal Sim Pair
Ac va on No Ac va on
Connec on
Flip Screen
Yes
No
Choose Yes if Opus is installed upside down.
LCD will flip right side up when Control is upside down.
No
SECTION 8.4: Output Settings
Output Setting
Parameter
Terminal
Default
Range
Description
Output 1
Terminal 7
Fully Opened
►
— —
►
No Output
Position
►
Fully Closed Position
►
Output closes when fully closed
Output 2
Terminal 13 Fully Closed
►
Closing Status
►
Output closes when door is closing
Position
►
Opening Status
►
Output closes when door is opening
Relay Output 3 Relay Output
— —
►
Fully Opened Position
►
Output closes when door fully opened.
Terminals
►
Error State Output
►
Output closes when error detected
►
Recycle happened
►
Output closes when recycle occurs
►
Electric Strike Lock
►
Set for electric strike functionality (N.O.)
►
Electric Magnetic Lock
►
Set for Mag lock functionality (N.C.)
►
Air lock
►
Set for Air lock functionality
►
Breakout Pass through
►
Output closes when breakout occurs
►
TrmnL H PassThrough
►
Output changes state when input H changes state
►
Door Sequencing
►
Provision for door sequencing
►
Sensor Monitoring (N.O.)
►
Normally open Monitoring circuit
(high logic)
►
Sensor Monitoring (N.C.)
►
Normally closed Monitoring ciruit
(low logic)
►
Bodyguard Output
►
Outputs data for bodyguard sensors and other
sensors that utilize same data .
►
For Elite N Output
►
For Elite (N) sensor made by Optex. (Output 1 only)
Open Delay
Timer
N/A
0.4
0.5, 1.0, 1.5 sec
After Unlock Input
Delay time after activation to allow lock to unlock
before the door starts moving.
Only functional if Electric Lock is selected.
Sequence
Delay Timer
N/A
0
0-10, 12, 15, 20, 25
Same as Open Timer
Delay Time before second Door opens when an output
is being used for Door Sequencing.
Lock Condition N/A
Every Fully
Closed
Every Fully Closed
One way/Night Only
Determines when the electric lock engages.