28 of 32
Swing and Fold Door Opus Control Wiring and Programming Installation Manual
www.NabcoEntrances.com
P/N C-00139
Rev 8-11-21
SECTION 11.11: Connecting a Break-Out Switch
DN 1521
BREAKOUT
WITH
ON/OFF/HOLDOPEN SWITCH
ON/OFF/Hold-Open Switch
P/N A-00805
Break-out Switch wired in series with
Blue Wire from ON/OFF/Hold-Open Switch
Panic Latch Kit
P/N A-00430 (Clear)
A-70430 (Dark Bronze)
RED
BLACK
14
13
12
11
10
9
8
8
WHITE
Off
Hold Open
On
Off
14
13
12
11
10
9
8
8
14
BA (break-out input) must be set to N.C. on the
Opus Control (is by default).
Panic Latch must be mounted so that the:
• Switch is open when the Door is broken out.
• Closed when not broken-out
BREAKOUT
WITHOUT
ON/OFF/HOLDOPEN SWITCH
BA (break-out input) must be set to N.C. on the
Opus Control (is by default).
Panic Latch must be mounted so that the:
• Switch is open when the Door is broken out.
• Closed when not broken-out
BLUE
BLUE
BLUE
BLUE
BLUE