![Nabco C-00139 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/nabco/c-00139/c-00139_installation-manual_3088210019.webp)
19 of 32
www.NabcoEntrances.com
SwingandFoldDoorOpusControlWiringandProgrammingInstallationManual
Rev. 8-11-21
P/N C-00139
CHAPTER 10: SHUT OFF CIRCUIT BREAKER
Shut the installation site branch Circuit Breaker OFF. Failure to do so may result in serious
personal or fatal injury. When uncertain whether power supply is disconnected, always verify
using a voltmeter.
All high voltage electrical connections must be made by licensed electricians according to
National and Local electrical codes/regulations.
Permanent wiring shall be employed as required by local codes.
Electrical circuit to Nabco operator must not be not shared with other equipment such as
lighting, cash registers, or any device that might cause electrical interference on the circuit.
Keep sufficient spacing between high-voltage and low-voltage wiring. 120 VAC Power wires
must be routed (separate from other wiring) located near the top of inside Header.
Ensure that incomming electrical ground is properly secured to the grounding screw or
grounding wire, whichever is provided.
Attention: Insert all Incoming 120 VAC Power wires into the pre drilled Electric Service Access Hole located at the
left or right side of Header End Cap.
Attention: Electrical circuit to Nabco operator must not be not shared with other equipment such as lighting,
cash registers, or any device that might cause electrical interference on the circuit.
Attention: Any non-factory low voltage wiring added inside the Header must be Type CL2 wire or the equivalent
in accordance with Article 725 of the NEC.
Note: It is recommended for the Installer to house all Incoming 120 VAC wires within an Electrical Conduit.
CHAPTER 11: SWING DOOR WIRING DIAGRAMS
SECTION 11.1: 120 VAC General Wiring
SINGLE
120 VAC
SIMULTANEOUS PAIR
120 VAC
14
13
12
11
10
9
8
7
6
5
4
3
2
1
14
13
12
11
10
9
8
7
6
5
4
3
2
1
14
13
12
11
10
9
8
7
6
5
4
3
2
1
2
1
2
1
2
1
DN 1335
Ground Screw
Opus Control
Motor
BLACK
BLACK
BLACK
WHITE
HOT
NEUTRAL
GROUND
GREEN
Opus Control
BLACK
WHITE
BLACK
GREEN
Opus Control
Motor
Motor
BLACK
BLACK
BLACK
WHITE
HOT
NEUTRAL
GROUND
ON/OFF
Rocker
Switch
ON/OFF
Rocker
Switch
Ground Screw
WARNING
WARNING
CAUTION
CAUTION
CAUTION
CAUTION