Mydax, Inc. 

1M150W 

Water Cooled Chiller 

 

 

Designed for Lockheed Martin   

 

 

FRONT PANEL CONTROLS

 

 
 
All Mydax chillers are controlled by a microprocessor which is accessed via the system control panel.  System controls 
are simple, yet powerful and in concert with built-in diagnostics and error messages, are exceptionally comprehensive. 
 

POWER LED:

   

Indicates unit is powered (the circuit breaker is set). 

 

RESET:

 

 

Must be pressed prior to system start-up to energize the interlock loop. 

 
 

DISPLAY:

 

 
 

Shows the actual Output Temperature and Setpoint Temperature in 

°

C.  Also indicates that 

the local SET TEMPERATURE MODE can be enabled.  Additionally, the recirculation flow 
rate is displayed in gallons-per-minute (Gpm), as well as the water resistivity. 

 
START:

 

 

Starts compressor and pump and turns on LED's.  

 

STOP:

   

 

Stops both the compressor and pump. 

 

MUTE ALARM:

 

May be used to deactivate audible alarm for 10 minutes, leaving alarm LED on.  Pressing the 
CLEAR key reactivates the alarm, which sounds until the fault condition is eliminated or the 
MUTE ALARM switch is depressed again.  Pressing MUTE ALARM when no alarm is 
active causes the alarm to sound once and the TEST ALARM display to appear. 

 

SET:

 

 

 

Enables SET TEMPERATURE MODE.  SET MODE is disabled from panel if an alarm is 
active or if the unit is in REMOTE.  To set, depress: 

 

SET:

 

 

 

"Set Mode" appears at the right of the display.  Cursor flashes at 
"units" digit of the temperature display. 

 

ARROWS KEYS:

 

Changes temperature setting in one degree increments unless "." 
(decimal) key is depressed. 

 

"." (DECIMAL):

 

Moves cursor to the "tenths" digit of the temperature display and 
causes arrow keys to change setting in tenths of a degree. 

 

KEYPAD:

 

 

Changes temperature setting by entering numbers directly. 

 

CLEAR:

 

 

Erases an incorrect entry. 

 

ENTER:

 

 

Selects temperature setting and deselects SET mode. 

 

TEST:

   

 

Initiates Test Mode.  See description under DIAGNOSTIC DISPLAYS section of this 
manual. 

 

ENTER:

 

 

Enters temperature selections while in the SET mode. 

 

CLEAR:

 

 

Erases incorrect temperature selections; exits Test Mode; clears Mute Alarm selection. 

 

MODE:

  

 

Toggles between the optional RS-232C remote control mode, when present, and Local Set 
mode. 

 

 Tank        --- MYDAX ---     Local Set 

 21.50°C    40.0 Gpm    400K

   25.0°C

 

Содержание 1M150W

Страница 1: ...vanced temperature control technology MYDAX INC INSTRUCTION OPERATION MANUAL 1M150W WATER COOLED CHILLER MYDAX INC 12260 Shale Ridge Road Auburn CA 95602 530 888 6662 FAX 530 888 0962 http www mydax c...

Страница 2: ...YSTEM OVERVIEW 4 INSTALLATION 6 FRONT PANEL CONTROLS 8 ALARM ERROR MESSAGES 10 DIAGNOSTIC DISPLAYS 11 SERVICE WARRANTY 14 SHIPPING STORAGE PROCEDURE 15 DRAWINGS PARTS LIST FRAME DRAWING FLUID DIAGRAM...

Страница 3: ...70 F 7 Gpm 40 F 20 PSI differential Electrical Service 460 480 VAC 60 Hz 3 phase 50 amp service Physical Parameters 65 H x 36 W x 58 D 1000 lbs dry weight STANDARD FEATURES This chiller is complete wi...

Страница 4: ...reas where potentially harmful conditions exist and in this manual to bring attention to such conditions This chiller uses materials that are subject to environmental regulations be sure to familiariz...

Страница 5: ...mpressor is hermetically sealed and no service should be required In the event that cleanup is necessary absorb oil with oil absorbent material and dispose of as a hazardous waste Follow approved clea...

Страница 6: ...TD s resistance temperature devices located about the circuit The drawing shows RTD s at the discharge line leading from the recirculating pump at the return line leading to the reservoir between the...

Страница 7: ...one power relay coil and a relay pole RL1 B The RESET switch serves to feed power to the relay which energizes the contactor When energized the contactor feeds power back to the relay so the RESET swi...

Страница 8: ...e starting to allow the crankcase heater to separate the refrigerant from the oil CONDENSER FLOW The condenser inlet and outlet fittings are 1 stainless steel female pipe thread fittings FPT Plumb the...

Страница 9: ...ow rate is visible on the front LCD display panel BYPASS VALVE To divert the recirculation flow from the output path back to the tank first open the Bypass valve then close the output flow adjustment...

Страница 10: ...ition is eliminated or the MUTE ALARM switch is depressed again Pressing MUTE ALARM when no alarm is active causes the alarm to sound once and the TEST ALARM display to appear SET Enables SET TEMPERAT...

Страница 11: ...decrements toggles tank temperature setpoint temperature and evaporator data view modes for multiple channel systems DECIMAL Display shows model number and software revision date and copyright RUN PU...

Страница 12: ...s too close to freezing 4 C The microprocessor shuts down the system with a fatal alarm Push Reset Indicates that a fatal alarm in the interlock circuit has occurred and the operator must push the Res...

Страница 13: ...a direct indicator of condenser temperature and pressure The microprocessor sends the CONDENSER HOT error message if the condenser temperature exceeds 54 C TEST PANEL 3 The first 3 sets of 4 digit nu...

Страница 14: ...e the Flow OK relay below the selected GPM The output of the relay is wired to a BNC connector labeled Flow OK located on the rear panel of the unit The shield and center pin are the normally open con...

Страница 15: ...setpoint temperatures of whichever recirculating channel was last selected at the Main Display and the system wide alarm history The second line indicates which recirculating channel was last selecte...

Страница 16: ...use of a torch In particular service of Mydax refrigeration circuits requires attention to the following 1 Use caution to protect components from heat damage 2 Prevent any moisture from entering the...

Страница 17: ...en run with water ethylene glycol should be added to the recirculating loop Verify that the concentration of ethylene glycol approaches 50 measure with a hydrometer in the recirculating loop before dr...

Отзывы: