2) The mode button for mode selection. Press this button to choose what the mode do your want.

( H

ffective for electric heating model).

NOTE

: Press mode button to switch the current mode. When AUTO mode is displayed as the default 

for the dehumidifi heating mode, at this time can not adjust the settings on the remote control 
humidity and heating temperature.
3) Vane control button can control the vane  blade rotation direction, on and off.
4) Timing setting

In the boot of the state, according to timer key OFF key can be set with timing off. Press OFF button

continuously, you can adjust the values, after the adjustment press the confirm button, timing off setting
is completed. Press the Cancel button to cancel timer settings. 
    In shutdown mode, press the timer button ON button can be set with timing on. Continually press ON 
button, you can adjust the values, after the adjustment, press the confirm button, timing on setting is 
completed. Press the Cancel button, cancel the timer settings.

NOTE

: No remote control function parameters, only the default mode, so when the remote control 

unit, according to the actual situation of the control unit.

The unit has four modes to choose from, dehumidification mode display

DRY

 icon, air supply

mode display

FAN 

icon, heating mode display

 HEAT 

 icon. dehumidification plus heating mode 

display

 AUTO 

icon .   

eating mode e

    

    

 

DEHUMIDIFIER

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

AC-N

OUT3

OUT2

OUT1

CN3

CN4

CN19

OUT4

OUT5

SW1

LED

23
22
21
20
19 
18
17
16

FUSE

6.Connection of PCB illustration

Display

AC-L 

AC-L 

Symbol 

                             

Meaning

Electric heater /heating water pump output 

NO .             

Reservation

High speed wind terminal

Compressor power output

LCD/LED Wire controller

Reservation

OUT1

OUT2
OUT3
OUT4
OUT5

CN1

CN3

CN4

AC-L

01/02/03

04/05

06/07

08/09

10/11

12/13

14/15

16/17/18

19

20/21

22/23

System coil temperature

Ambient temperature

Ambient temperature

Power input(AC-L)

Transformer primary coils

Turn on /turn off  switch

Infrared remote  control switch

Auxiliary heating overload  PT switch

Low pressure switch

High pressure switch

Phase sequence protection switch

Humidity sensor

24/25

Display

Low speed wind terminal

CN2

Transformer secondary coils

AC-N

Power  input(AC-N)

2

1

NOTE:       Infrared remote control switch short circuit: turn on    open circuit: turn off

       When the wired remote is damaged, disconnect the wired remote, infrared remote 

 control unit to run through the unit.  If the remote is damaged or missing, disconnect the

 Infrared remote control switch 

, by 

 Turn on / Turn off  switch 

to control the unit,

  the default mode for dehumidification mode!

CN2

CN1

Infrared receiver signal output
(effective for the mode of ABS)

2

1

Stepping motor signal output

CN19

Содержание ABS 12A

Страница 1: ...DEHUMIDIFIER...

Страница 2: ...ed mode The requirement of installation place Installation requirement Hot water pipe connection Electric wiring 1 2 3 Preface Important Safety Instructions Products Principle 4 Principle descdiption...

Страница 3: ...t operate in a closed confined space Please keep this manual Note We recommend that any repairs must be professional 2 Products Installed dehumidifiers to reduce humidity in the air the room so people...

Страница 4: ...Protect your enviroment Even when you cannot see it moisture in the form of water vapour is all around us held in suspension in the air The relative humidity of the air in many cases determines the ex...

Страница 5: ...g e r a n t Compressor Net weight Gross weight Net dimension Packaging dimension A B C MBA Size A B C 2 The dimension for dehumidifier 2 1 ABS wall mounted mode 7A 905 243 673 Units mm 1288 1672 243 2...

Страница 6: ...ller in the electrician base box and tighten the two setscrews Illustration 3 Illustration 4 Illustration 1 Illustration 2 Use flat screwdriver to press down the two back off and lift open the face co...

Страница 7: ...SET Defrost status M SET M SET Keep flash Keep flash out 5 45 Ambient temperature of the unit can not properly dehumidify 1 The button after on this button you can change the fan speed Parameter quer...

Страница 8: ...s to change the setting time press ON OFF button to cancel the timer when finish the timing setting press to confirm exit In the case of the boot you can press the button set the unit off after how ma...

Страница 9: ...mode display FAN icon heating mode display HEAT icon dehumidification plus heating mode display AUTO icon eating mode e DEHUMIDIFIER 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 AC N OUT3 OUT2 OUT1 CN...

Страница 10: ...position can hold the outdoor unit without noise and shake 2 3 No sunlight to the unit Set an awning if necessary 2 4 The water from rain and defrosting can be discharged in the installation position...

Страница 11: ...the machine As shown below Swimming pool Not the corner Swimming pool 3 10 Open the front grille plastic case you can see the plastic plate around the screw open the screw only after about two plasti...

Страница 12: ...r construction of plumbing standards 4 3 After hot water pipes connected it must be pipe connection rigorous testing plus 0 7Mpa pressure testing 24 hours system pipes connector no leakage and clean a...

Страница 13: ...connection take the unit power line remote control three core lines electric heater power line solar circulated water pump control power line water tank temperature sensing line solar collector temper...

Страница 14: ...or solvents may cause local adverse effects and use the tank water leakage occurred 5 6 The long term no use please pull the plug Cleaning the machine please stop and pulled out the power plug otherw...

Страница 15: ...when all the mode setting the system meet power failure a orsuddenly meet without tight slide in power the system can automatically stored before the operation state in the next time in power system...

Страница 16: ...ng normal or not Detection of the heating water supply system s normal Check the power phase sequence whether misphase Check humidity wire controller connection is normal or not 5flash 1 off 6flash 1...

Страница 17: ...oil temp Switch High pressure switch Low pressure switch Electric protection switch LCD LED wire controller Turn on Turn off Compressor R S Blue White Capacitance Capacita nce Grey Yellow Red Fan Oran...

Страница 18: ...l switch short circuit turn on cut turn off 1 NOTE Hot water cycle pump effective for the unit with heating coil function 2 WIRING DIAGRAM C Red AC N OUT3 OUT2 OUT1 CN1CN2 CN3 CN4 CN19 OUT4 OUT5 SW1 L...

Страница 19: ...ressure switch HP1 LP1 P6 Legend Power phase protection switch Yellow White Red Humidity sensor Yellow WIRING DIA DIAGRAM 2 Infrared remote control switch short circuit turn on cut turn off 1 NOTE Hot...

Отзывы: