2) The mode button for mode selection. Press this button to choose what the mode do your want.
( H
ffective for electric heating model).
NOTE
: Press mode button to switch the current mode. When AUTO mode is displayed as the default
for the dehumidifi heating mode, at this time can not adjust the settings on the remote control
humidity and heating temperature.
3) Vane control button can control the vane blade rotation direction, on and off.
4) Timing setting
In the boot of the state, according to timer key OFF key can be set with timing off. Press OFF button
continuously, you can adjust the values, after the adjustment press the confirm button, timing off setting
is completed. Press the Cancel button to cancel timer settings.
In shutdown mode, press the timer button ON button can be set with timing on. Continually press ON
button, you can adjust the values, after the adjustment, press the confirm button, timing on setting is
completed. Press the Cancel button, cancel the timer settings.
NOTE
: No remote control function parameters, only the default mode, so when the remote control
unit, according to the actual situation of the control unit.
The unit has four modes to choose from, dehumidification mode display
DRY
icon, air supply
mode display
FAN
icon, heating mode display
HEAT
icon. dehumidification plus heating mode
display
AUTO
icon .
eating mode e
DEHUMIDIFIER
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
AC-N
OUT3
OUT2
OUT1
CN3
CN4
CN19
OUT4
OUT5
SW1
LED
23
22
21
20
19
18
17
16
FUSE
6.Connection of PCB illustration
Display
AC-L
AC-L
Symbol
Meaning
Electric heater /heating water pump output
NO .
Reservation
High speed wind terminal
Compressor power output
LCD/LED Wire controller
Reservation
OUT1
OUT2
OUT3
OUT4
OUT5
CN1
CN3
CN4
AC-L
01/02/03
04/05
06/07
08/09
10/11
12/13
14/15
16/17/18
19
20/21
22/23
System coil temperature
Ambient temperature
Ambient temperature
Power input(AC-L)
Transformer primary coils
Turn on /turn off switch
Infrared remote control switch
Auxiliary heating overload PT switch
Low pressure switch
High pressure switch
Phase sequence protection switch
Humidity sensor
24/25
Display
Low speed wind terminal
CN2
Transformer secondary coils
AC-N
Power input(AC-N)
2
1
NOTE: Infrared remote control switch short circuit: turn on open circuit: turn off
When the wired remote is damaged, disconnect the wired remote, infrared remote
control unit to run through the unit. If the remote is damaged or missing, disconnect the
Infrared remote control switch
, by
Turn on / Turn off switch
to control the unit,
the default mode for dehumidification mode!
CN2
CN1
Infrared receiver signal output
(effective for the mode of ABS)
2