Parameters C5
Parameters C6
Parameters C7
The temp. point to enter defrosting
mode
Setting range: (-5 ~-10
)
Default 0
Exit defrost temperature
Setting range: (0 ~15 )
Default 8
Exit defrosting cycle
Setting range: (1-12Min)
default setting: 8Min
M
SET
M
SET
M
SET
2) The
button and
button.
When working, if it is dehumidifying mode, each press
button once, set the humidity
plus 1%, when in heating mode, the temperature increases 1
; when in dehumidifier plus
heating mode, you can switch the humidity and temperature by the
button.
When the setting temperature or humidity to the maximum setting, then press the
button at the same time for 3 seconds, set given temperature and humidity remains
unchanged.
3) Timed ON/OFF setting. Timed ON setting
Press the
button: to enter the timing setting. By
and
buttons to change
the setting time, press ON / OFF button to cancel the timer, when finish the timing setting, press
to confirm exit.
In the case of the boot, you can press the
button, set the unit off after how many
hours.
In the case of the shutdown, you can press the
button, set the unit start after how many
hours.
NOTE
:
5.Functional illustration of the remote controller
MODE
FAN
35
FAN
OFF
ON
TIMER
CANCEL
CONFIRM
Operation mode
Set value display
Timing display
Speed display
Mode button
Fan speed setting
Vane control key
Useless button
Useless button
Timing setting confirm
Timing setting cancel
Timing setting on
Timing setting off
ON/OFF button
Down button
Up button
1) ON/OFF button. Press this button to power on and off. In the ON mode, the remote controller displays
the operation mode, fan speed, ambient temperature
and the humidity .
Parameters C8
Fan operation mode after the compressor
stop.
range:(0: turn of f 1:keep moving
2:every 20min the fan running 30 second.)
default setting: 2
M
SET
DEHUMIDIFIER