4.Fault code description
The dehumidifier automatically determine fault with features such as failure, in the humidity
in the display fault code will appear.
E1
Temperature
sensor fault
E2
Humidity sensor
failure
Issue
Problems Solutions
1.Temperature sensor connection is normal
or not.
2.Check the filter is blocked or not
Check whether the unit is running hot
Check humidity sensor connection is normal
or not
E3
E4
System coil temp.
Sensor failure
System high pressure
protection.
Check coil temp sensor connection is normal
or not
Running lights
display
Wired remote
display
1flash 1 off
2flash 1 off
3flash 1 off
4flash 1 off
E5
E6
E8
EE
System low pressure
protection.
Electric heater
overheating protection
Phase sequence
protection
Communication
failure
Check whether the unit is running normal or not
Detection of the heating water supply system
s normal
Check the power phase sequence whether
misphase.
Check humidity wire controller connection is
normal or not.
5flash 1 off
6flash 1 off
8flash 1 off
Keep flash
7flash 1 off
Keep flash
Keep flash
Under the dehumidification mode, the non-normal ambient
temperature protection.
Defrost status
DEHUMIDIFIER
Leakage
1.Tilt the machine
2.Outlet pipe plug
1.Place the machine is not smooth
2.Filter is blocked
1.Adjust the machine level
2.Remove the pane to remove tube
booty
Abnormal noise
1.Reposition the machine steady
2.Clean the air filter
5.Wiring diagram
Mk3077
FUSE
1234
ON
DIP
T
S
R
N
P5
P6
0057W
0057W
JK1
IC6
CON1
12V-IN 12V-OUT
L1
L2
Power
Run
5.1. Power phase sequence protection board description
Power input
Power input
Power input
Power input
Protection signal output
Protection signal output
Connect transformer power(12VAC)input
power(12VAC)output
Meaning
Meaning
Symbol
Symbol
NO .
NO
R
S
T
N
P5
P6
12V-IN
12V-OUT
1
2
3
4
5
6
7
8