background image

www.mycond.co.uk

18

WIRING DIAGRAM 

2

               Infrared remote control switch. 

    (short circuit: turn on   cut: turn off) 

1

NOTE:

               Hot water cycle pump
               effective for the unit with heating

    coil function.

2

CN2

R     S      T    N

KM1

Compressor

C R S

 Power input
(380VAC/3PH/50Hz)

Black

Red

White

Blue

TC

White

Water cycle 
pump
(220VAC)

Fuse(220V/5A)

Red

Black

W

hite

12

34

ON

DIP

CO

N1

T

S

R

FUSE

L1

L2

Power

 

Run

   

12V-IN

12V-OUT

Mk3077

0057W

JK1

P6

P5

N

0057W

CN1

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

AC-N

OUT3

OUT2

OUT1

OUT4

OUT5

23
22
21
20
19
18
17
16

Black

Fan

White

Red

Brown

Capacitance 

L       N  

Orange

Blue

Y

ellow

Wire controller

KM1

SW1

LP1

HP1

P5 P6

SW2

SW3

T

T

T1

T2

KM1:  Compressor A.C.contactor

      

  :  A.C.contactor/relay coil

        

:Ambient temp.
:Coil temp.

 

T

T1

T

T2

 

: Auxiliary electric heatter 
 overload PT switch(closed circuit)
: Infrared remote control switch
: Mode select switch

SW1

SW2
SW3

P5

 
: High pressure switch
: Low pressure switch

 

HP1
LP1

P6

Legend 

:Power phase protection switch

 Yellow
 White
 Red

 Humidity 

 sensor

Yellow

WIRING

 

DIA 

DIAGRAM 

2

               Infrared remote control switch. 

    (short circuit: turn on   cut: turn off) 

1

NOTE:

               Hot water cycle pump
               effective for the unit with heating

    coil function.

2

CN2

R     S      T    N

KM1

Compressor

C R S

 Power input
(380VAC/3PH/50Hz)

Black

Red

White

Blue

TC

White

Water cycle 
pump
(220VAC)

Fuse(220V/5A)

Red

Black

White

12

34

ON

DIP

CO

N1

T

S

R

FUSE

L1

L2

Power

 

Run

   

12V-IN

12V-OUT

Mk3077

0057W

JK1

P6

P5

N

0057W

CN1

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

AC-N

OUT3

OUT2

OUT1

OUT4

OUT5

23
22
21
20
19
18
17
16

Black

Fan

White

Red

Blue/brown

Capacitance 

L       N  

Orange

Blue

Y

ellow

Wire controller

KM1

SW1

LP1

HP1

P5 P6

SW2

SW3

T

T

T1

T2

KM1:  Compressor A.C.contactor

      

  :  A.C.contactor/relay coil

        

:Ambient temp.
:Coil temp.

 

T

T1

T

T2

 

: Auxiliary electric heatter 
 overload PT switch(closed circuit)
: Infrared remote control switch
: Mode select switch

SW1

SW2
SW3

P5

 
: High pressure switch
: Low pressure switch

 

HP1
LP1

P6

Legend 

:Power phase protection switch

 Yellow
 White
 Red

 Humidity 

 sensor

DEHUMIDIFIER

Содержание ABS 12A

Страница 1: ...DEHUMIDIFIER...

Страница 2: ...ed mode The requirement of installation place Installation requirement Hot water pipe connection Electric wiring 1 2 3 Preface Important Safety Instructions Products Principle 4 Principle descdiption...

Страница 3: ...t operate in a closed confined space Please keep this manual Note We recommend that any repairs must be professional 2 Products Installed dehumidifiers to reduce humidity in the air the room so people...

Страница 4: ...Protect your enviroment Even when you cannot see it moisture in the form of water vapour is all around us held in suspension in the air The relative humidity of the air in many cases determines the ex...

Страница 5: ...g e r a n t Compressor Net weight Gross weight Net dimension Packaging dimension A B C MBA Size A B C 2 The dimension for dehumidifier 2 1 ABS wall mounted mode 7A 905 243 673 Units mm 1288 1672 243 2...

Страница 6: ...ller in the electrician base box and tighten the two setscrews Illustration 3 Illustration 4 Illustration 1 Illustration 2 Use flat screwdriver to press down the two back off and lift open the face co...

Страница 7: ...SET Defrost status M SET M SET Keep flash Keep flash out 5 45 Ambient temperature of the unit can not properly dehumidify 1 The button after on this button you can change the fan speed Parameter quer...

Страница 8: ...s to change the setting time press ON OFF button to cancel the timer when finish the timing setting press to confirm exit In the case of the boot you can press the button set the unit off after how ma...

Страница 9: ...mode display FAN icon heating mode display HEAT icon dehumidification plus heating mode display AUTO icon eating mode e DEHUMIDIFIER 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 AC N OUT3 OUT2 OUT1 CN...

Страница 10: ...position can hold the outdoor unit without noise and shake 2 3 No sunlight to the unit Set an awning if necessary 2 4 The water from rain and defrosting can be discharged in the installation position...

Страница 11: ...the machine As shown below Swimming pool Not the corner Swimming pool 3 10 Open the front grille plastic case you can see the plastic plate around the screw open the screw only after about two plasti...

Страница 12: ...r construction of plumbing standards 4 3 After hot water pipes connected it must be pipe connection rigorous testing plus 0 7Mpa pressure testing 24 hours system pipes connector no leakage and clean a...

Страница 13: ...connection take the unit power line remote control three core lines electric heater power line solar circulated water pump control power line water tank temperature sensing line solar collector temper...

Страница 14: ...or solvents may cause local adverse effects and use the tank water leakage occurred 5 6 The long term no use please pull the plug Cleaning the machine please stop and pulled out the power plug otherw...

Страница 15: ...when all the mode setting the system meet power failure a orsuddenly meet without tight slide in power the system can automatically stored before the operation state in the next time in power system...

Страница 16: ...ng normal or not Detection of the heating water supply system s normal Check the power phase sequence whether misphase Check humidity wire controller connection is normal or not 5flash 1 off 6flash 1...

Страница 17: ...oil temp Switch High pressure switch Low pressure switch Electric protection switch LCD LED wire controller Turn on Turn off Compressor R S Blue White Capacitance Capacita nce Grey Yellow Red Fan Oran...

Страница 18: ...l switch short circuit turn on cut turn off 1 NOTE Hot water cycle pump effective for the unit with heating coil function 2 WIRING DIAGRAM C Red AC N OUT3 OUT2 OUT1 CN1CN2 CN3 CN4 CN19 OUT4 OUT5 SW1 L...

Страница 19: ...ressure switch HP1 LP1 P6 Legend Power phase protection switch Yellow White Red Humidity sensor Yellow WIRING DIA DIAGRAM 2 Infrared remote control switch short circuit turn on cut turn off 1 NOTE Hot...

Отзывы: