9 Troubleshooting
VJ-1604
Maintenance Manual
Rev.-00
9-6
1
6. CR board assembly
may be damaged.
Replace CR board
assembly.
Replacing CR
Board
Assembly"
p.4-106
7. Check presence of
media from "Sen
7:PaperRear" of
self-diagnosis
function.
When "No media" is
displayed even if media
is set, replace P_REAR
sensor.
Replacing
P_REAR
Sensor
Assembly"
p.4-65
8. Main board
assembly may be
damaged.
Replace MAIN board
assembly.
2
Media skew
error
Media is
running
obliquely.
1. Set media again and
check reappearance.
If this error is caused by
user's inappropriate
media setting, instruct
correct media setting
procedure.
-
2. Is suction fan
judged as normal
when checked
through "Test 6:
Fan" of self-
diagnosis function?
- Check connection of
following MAIN board
assembly connectors.
•
Suction fan 1 cable:
J25
•
Suction fan 2 cable:
J26
•
Suction fan 3 cable:
J28
•
Suction fan 4 cable:
J29
•
Replace suction fan
assembly.
•
Replace cable of
suction fan that does
not operate
normally.
3. Is shielding material
secured at specified
position?
Remount it at specified
position.
-
4. Check pressure
lever operation.
Apply grease (G501) to
pressure cam and make
adjustment.
Table 9-3 Symptoms and Check Items for Errors with Message(Continued)
No.
Message
Event/
symptom
Check item
Action
Reference
Содержание ValuejetVJ-1604
Страница 2: ......
Страница 14: ...VJ 1604 Maintenance Manual 12 ...
Страница 24: ...1 Safety Instructions VJ 1604 Maintenance Manual Rev 00 1 10 ...
Страница 42: ...3 Specifications VJ 1604 Maintenance Manual Rev 00 3 8 ...
Страница 198: ...4 Parts Replacement VJ 1604 Maintenance Manual Rev 00 4 156 ...
Страница 266: ...5 Self Diagnosis Mode VJ 1604 Maintenance Manual Rev 00 5 68 ...
Страница 404: ...10 Appendix VJ 1604 Maintenance Manual Rev 00 10 8 ...
Страница 420: ...VJ 1604 Maintenance Manual Supplement Exploded View 16 ...
Страница 421: ......
Страница 422: ......