5 Self-Diagnosis Mode
VJ-1604
Maintenance Manual
Rev.-00
5-50
(1) Head Rank
This menu updates the head rank parameters. The head rank is used to determine the print head driving
voltage and correct the head temperature.
After head rank is entered, the system shifts to the Ink Charge Menu.
(2) Voltage Adjustment
This menu updates the voltage adjustment parameter (VSD3 small dot).
Table 5-15 Voltage adjustment item
Items
Contents
240 CW
Adjusts the VSD 3-L (S) at 240 cps. CW printing.
240 CCW
Adjusts the VSD 3-L (S) at 240 cps. CCW printing.
320 CW
Adjusts the VSD 3-L (S) at 320 cps. CW printing.
320 CCW
Adjusts the VSD 3-L (S) at 320 cps. CCW printing.
[Enter] key
[Enter] key
[Enter] key
[Enter] key
[Enter] key
[Enter] key
[Enter] key
Error will occur if input value is wrong.
Press [Enter] key to retry
Initial Ink charge will not executed.
Head ID will be updated.
[Cancel]
key
[>] keys
[>] key
[>] key
[>] key
If 240 CW is selected
[<] key
[<] key
[<] key
[<] key
Offset range: -5V to 5V (0.1V increment)
VH3L-1 to VH3L-4
VH3S-1 to VH3S-4
Содержание ValuejetVJ-1604
Страница 2: ......
Страница 14: ...VJ 1604 Maintenance Manual 12 ...
Страница 24: ...1 Safety Instructions VJ 1604 Maintenance Manual Rev 00 1 10 ...
Страница 42: ...3 Specifications VJ 1604 Maintenance Manual Rev 00 3 8 ...
Страница 198: ...4 Parts Replacement VJ 1604 Maintenance Manual Rev 00 4 156 ...
Страница 266: ...5 Self Diagnosis Mode VJ 1604 Maintenance Manual Rev 00 5 68 ...
Страница 404: ...10 Appendix VJ 1604 Maintenance Manual Rev 00 10 8 ...
Страница 420: ...VJ 1604 Maintenance Manual Supplement Exploded View 16 ...
Страница 421: ......
Страница 422: ......