VJ-1604
Maintenance Manual
4 Parts Replacement
4-77
Rev.-00
1. Remove the platen.
"(2) Replacing Platen Heater, Platen Thermistor" p.4-72
2. Remove the connector to the suction fan.
3. Remove the screws (2 pieces) that retain the suction fan.
4. Remove the suction fan.
5. Replace the suction fan.
6. To reassemble the unit, reverse the removal procedure.
4.6.9
Replacing Platen Non-Reflective Tape
1. Open the front cover.
2. Strip the platen non-reflective tape.
No.
Part name
1
Suction fan
2
Screws that retain the suction fan
(pan-head screw with spring washer and flat washer M4
×
10)
3
Connector to the suction fan
3
2
1
2
1