VJ-1604
Maintenance Manual
7 Adjustment
7-25
Rev.-00
7.5 PF Encoder Assembly Position Adjustment
This section describes the procedure to adjust the PF encoder assembly.
After replacing the PF encoder, adjust the PF encoder position.
7.5.1
Adjustment Procedure
To adjust PF encoder, follow the steps below.
1. Remove the side maintenance cover L.
"4.2.5 Removing Side Maintenance Cover L" p.4-12
2. Loosen the screws that retain PF encoder.
3. Align the PF encoder assembly so that the corner covers the periphery of the PF encoder scale, then retain
the PF encoder assembly with screws.
NOTE
Align the PF encoder so that the encoder scale slit periphery came very close to the corners of the PF
encoder.
4. Attach the slit guide to the PF encoder assembly.
No.
Part name
1
Slit guide
2
Scale
3
PF scale assembly
PF encorder scale
PF encorder
PF encorder scale
come very close to
this point.