5 Self-Diagnosis Mode
VJ-1604
Maintenance Manual
Rev.-00
5-58
5.13.2 PF Motor Endurance Menu
This menu performs endurance running for the PF motor.
You can drive the PF motor according to your desired settings. The available settings are shown below.
TIP
• The following table shows the motor moving parameters to media feed amount.
• If the number of endurance running cycles is set to -1, the carriage continuously repeats endurance
running until cancel input is given from the operation panel.
• The maximum counter value for endurance running cycles is 99999999 (up to 8-digit number). If the
number of cycles exceeds the maximum value, the counter is reset to 0.
Table 5-21 Set Items in PF Motor Endurance Menu
Set item
Contents
Set value
Remark
Media feed amount
Set the media feed amount
per endurance running
cycle
0.1 to 100
Unit: mm
Number of endurance
running cycles
Set the number of
endurance running cycles
-1 to 10000
Speed
35CPS
Acceleration
0.1G
Deceleration
0.1G
Enter a media feed amount by using ±.
Range : 0.1 to 100.0 mm
Endurance Count
Performing endurance
[Enter]
[Enter]
[Enter] or [Cancel]
Содержание ValuejetVJ-1604
Страница 2: ......
Страница 14: ...VJ 1604 Maintenance Manual 12 ...
Страница 24: ...1 Safety Instructions VJ 1604 Maintenance Manual Rev 00 1 10 ...
Страница 42: ...3 Specifications VJ 1604 Maintenance Manual Rev 00 3 8 ...
Страница 198: ...4 Parts Replacement VJ 1604 Maintenance Manual Rev 00 4 156 ...
Страница 266: ...5 Self Diagnosis Mode VJ 1604 Maintenance Manual Rev 00 5 68 ...
Страница 404: ...10 Appendix VJ 1604 Maintenance Manual Rev 00 10 8 ...
Страница 420: ...VJ 1604 Maintenance Manual Supplement Exploded View 16 ...
Страница 421: ......
Страница 422: ......