Figure 8.6.1.8
Figure 8.6.1.8 shows the first
I/O Settings
tab contents, corresponding to Bank 6 GPIO configurations other than alternate
GPIO functions. This tab allows the direction of the GPIO ports to be set both for
active and sleep modes, and in the case of GPIO outputs, the initial power up states and sleep mode states to be set.
When GPIO ports 0 - 3 are configured as inputs, event interrupts can be set for them with check boxes. The type of inter-
rupt trigger is selected from the drop-down boxes to the right of the check boxes. Periodic I/O reporting, reporting interval
and enable/disable sleep I/O states and I/O binding can also be configured under this tab.
Figure 8.6.1.9
Figure 8.6.1.9 shows the second
I/O Setup
tab contents, corresponding to Bank 6 ADC input and DAC output parameters.
The ADC and DAC reference voltages, the ADC sampling interval, the high and low ADC thresholds for event reporting
and event reporting triggers on each ADC channel can be set, along with the initial output values for each DAC channel.
The event reporting I/O predelay and alternate GPIO functions can also be set from this tab.
©2009-2014 by Murata Electronics N.A., Inc.
DNT24 Integration Guide R2.0 - 10/27/14
www.murata.com
Содержание DNT24 Series
Страница 79: ...Figure 10 3 2 2009 2014 by Murata Electronics N A Inc DNT24 Integration Guide R2 0 10 27 14 www murata com...
Страница 80: ...Figure 10 3 3 2009 2014 by Murata Electronics N A Inc DNT24 Integration Guide R2 0 10 27 14 www murata com...
Страница 82: ...2009 2014 by Murata Electronics N A Inc DNT24 Integration Guide R2 0 10 27 14 www murata com...
Страница 83: ...2009 2014 by Murata Electronics N A Inc DNT24 Integration Guide R2 0 10 27 14 www murata com...